Storage Procedure
When a generator is in storage for any length of time, moisture condenses in the windings. Minimize the condensation by use of a dry storage space and space heaters. Refer to step 2 belowIf a brush-type generator (SRCR) is to be in storage for a year or more, lift the brushes off the slip ring to prevent damage to the slip ring by chemical action.After Storage
Test the main stator windings with a megohmmeter in the following situations: 1. Before initial startup of generator set.2. Every 3 months* if generator is operating in a humid environment.3. If generator has not been run under load for 3 months* or more.*This is a guideline only. It may be necessary to megger more frequently if environment is extremely humid, salty or if the last megger test was close to 1 megohm.The megohmmeter test is described in Service Manuals SENR2180 or SENR7968. A reading of 1 meghom or less indicates that the winding has absorbed too much moisture.To Remove Moisture
To remove moisture caused by high humidity, use one of the following methods to make the generator dry:1. Energize space heaters in generator if so equipped.2. Put the generator in an oven at a temperature of not more than 85°C (185°F) for four hours.
If an oven is used for drying, use a forced air type rather than a radiant type. Radiant ovens can cause localized overheating.
3. Space heaters of the same type used in marine applications, can be installed on generators. (See the Parts Book.) These heaters heat the windings to remove moisture and should be connected at all times in high humidity conditions whenever the generator is not running.4. Use a canvas enclosure around the generator and heating lamps to increase the temperature. Make an opening in the top for release of moisture.5. Send a low voltage current through the windings to increase the temperature of the windings. Do not exceed 85°C (185°F).If the megohmmeter test reads under 1 megohm after the drying or if it goes below 1 megohm shortly after drying, contact your Caterpillar dealer. The insulation has deteriorated and should be reconditioned.

Have questions with 104649-2592?





Group cross 104649-2592 ZEXEL

9 461 613 590 
 
FUEL-INJECTION PUMP
9 461 622 762 
 
FUEL-INJECTION PUMP
9 461 617 942 
 
FUEL-INJECTION PUMP
9 461 614 967 
NP-VE4/9F2300RNP1038 
 
FUEL-INJECTION PUMP
9 461 628 481 
 
FUEL-INJECTION PUMP
9 461 614 968 
NP-VE4/9F2300RNP1039 
 
FUEL-INJECTION PUMP
9 461 622 763 
 
FUEL-INJECTION PUMP
9 461 622 764 
 
FUEL-INJECTION PUMP
9 461 622 765 
NP-VE4/9F2500RNP719 
 
FUEL-INJECTION PUMP
9 461 625 560 
 
FUEL-INJECTION PUMP
9 461 622 766 
 
FUEL-INJECTION PUMP
104649-2592  
9 461 622 767 
 
FUEL-INJECTION PUMP
Back to top