Information fuel-injection pump
BOSCH
9 461 616 424
9461616424
ZEXEL
104645-3130
1046453130

Rating:
Include in #2:
104745-3130
as FUEL INJECTION PUMP
Cross reference number
Zexel num
Bosch num
Firm num
Name
Information:
Table 9
Byte(s) Byte Contents Detailed Description
1 $50 Indicates M5X protocol
2 $01 CCM is the sending module
3 $25 IID 25
4 $07 Number of bytes
5 $58 GSC number 1
6, 7 $00 $82 PID $0082 GSC Fault Log Codes, Status, And Number of occurrences
8, 9 $00 $BE CID 190 (engine speed sensor fault)
10 $C3 Count included, inactive fault, logged fault, standard FMI (3)
11 $04 Occurrence count of 4
12 $24 Checksum
IID 00 is used to request additional information on a fault 500000070058008300BEC34DIID 00 - Special parameter Command
Table 10
Byte(s) Byte Contents Detailed Description
1 $50 Indicates M5X protocol
2 $01 CCM is the sending module
3 $00 IID 00
4 $07 Number of bytes
5 $00 Reply in ASCII format
6 $58 GSC number 1
7, 8 $00 $83 PID $0083 GSC Fault Log Request For Additional Data
9, 10, 11 $00 $BE $C3 More information requested on CID 190 FMI 3
12 $4D Checksum
IID 25 will contain the reply as PID $0084 5001250B58008400BEC303000C001102IID 25 - Single Parameter Read Response
Table 11
Byte(s) Byte Contents Detailed Description
1 $50 Indicates M5X protocol
2 $01 CCM is the sending module
3 $25 IID 25
4 $0B Number of bytes
5 $58 GSC number 1
6, 7 $00 $84 PID $0084 GSC Fault Log Response For Additional Data
8, 9 $00 $BE CID 190
10 $C3 More information on FMI 3
11 $03 Three occurrences of this fault
12, 13 $00 $0C First occurrence at 12 hours
14, 15 $00 $11 Last occurrence at 17 hours
16 $02 Checksum Monitoring Generator Phase
The following example shows how to select which generator phase the GSC monitors.
Use IID 34 to write the parameters of PID $F0B0: 500034050048F0B0007FIID 34 - Single Parameter Write Request
Table 12
Byte(s) Byte Contents Detailed Description
1 $50 Indicates M5X protocol
2 $00 User's PC is the sending module
3 $34 IID 34
4 $05 Number of bytes
5 $00 Reply in ASCII format
6 $58 GSC number 1
7, 8 $F0 $B0 PID $F0B0 Generator Phase Select
9 $00 Phase A-B Voltage, Phase A Current
10 $7F Checksum
IID 35 is the response from the CCM: 5001350458F0B0007EIID 35 - Single Parameter Write Response
Table