104645-3121 ZEXEL 9 461 616 089 BOSCH FUEL-INJECTION PUMP 9461616089 1046453121


 

Information fuel-injection pump

BOSCH 9 461 616 089 9461616089
ZEXEL 104645-3121 1046453121
104645-3121 FUEL-INJECTION PUMP
Rating:
55
Buy FUEL-INJECTION PUMP 104645-3121 zexel genuine, new aftermarket engine parts with delivery

Include in #2:

104745-3121 as FUEL INJECTION PUMP

Cross reference number

Zexel num
Bosch num
Firm num
Name
104645-3121 
104645-3122 
9 461 616 089 
   
FUEL-INJECTION PUMP
* Q




Information:

Remote Fault Reset$00 $0D aUsed to reset faults on the CCM.
Table 2
(a)     $00 - $7F = Retain current CCM inactive fault status.
$80 - $FF = Reset CCM inactive fault.    Device ID Code$00 $80 aabbccUsed to read the device ID code from the CCM as well as other components on the data link. Each pair of bytes (aa, bb, cc) is sent LSB first.
Table 3
(aa)     Module ID: will always equal $61, data will be sent as $61 $00    
(bb)     Service Tool Support Change Level: $01, data will be sent as $01 $00    
(cc)     Application type:$FF $E0, data will be sent as $E0 $FF    CCM Error Codes$00 $82 abUsed to read the CCM Error Codes.
Table 4
(a)     bit 1 = Reserved    
(b) (1)     Fault Code Status    
bit 8     1 = RS-232C link message fault exists    
bit 7     1 = Miscellaneous Cat Data Link fault    
bit 6     1 = Invalid Cat Data message fault    
bit 5     1 = Internal buffer overflow on RS-232C or Data Data Link fault    
bit 4     1 = RS-232C short circuit fault    
bit 3     1 = Memory battery is weak    
bit 2     1 = M5X message error (checksum or byte count error)    
bit 1     1 = EEPROM fault    
( 1 ) A value of 0 (zero) in bits 1 through 8 indicates that particular fault does not exist.CCM Communication Rate Change Enable$AA $12 aUsed to determine if the CCM is connected to the host computer directly or remotely using a modem. Also used to enable or disable the host computers ability to change the communication rate of the RS-232C serial port.
Table 5
(a)     Bit 4     Reserved for Caterpillar.    
Bit 3 0 = Enable password protection
1 = Disable password protection    
Bit 2 0 = Enable baud rate change
1 = Disable baud rate change    
Bit 1 0 = Direct connection
1 = Modem connection    Access Level 1 Password$AA $87 aaaaaaaaUsed to read or program the Level 1 Password
Table 6
(aaaaaaaa)     Level 1 password in printable ASCII form. Must be at least 6, but no more than

Have questions with 104645-3121?





Group cross 104645-3121 ZEXEL

9 461 616 422 
NP-VE4/10F2100RNP1270 
 
FUEL-INJECTION PUMP
9 461 616 088 
 
FUEL-INJECTION PUMP
9 461 616 423 
 
FUEL-INJECTION PUMP
9 461 629 330 
NP-VE4/10F2000RNP1228 
 
FUEL-INJECTION PUMP
9 461 615 447 
 
FUEL-INJECTION PUMP
104645-3121  

104645-3122 
9 461 616 089 
 
FUEL-INJECTION PUMP
9 461 616 424 
 
FUEL-INJECTION PUMP
9 461 616 425 
 
FUEL-INJECTION PUMP
9 461 616 750 
 
FUEL-INJECTION PUMP
9 461 616 090 
 
FUEL-INJECTION PUMP
9 461 626 379 
 
FUEL-INJECTION PUMP
9 461 627 161 
NP-VE4/10F2000RNP1160 
 
FUEL-INJECTION PUMP
9 461 622 289 
NP-VE4/10F2100RNP1251 
 
FUEL-INJECTION PUMP
9 461 622 290 
 
FUEL-INJECTION PUMP
9 461 623 548 
 
FUEL-INJECTION PUMP
9 461 619 699 
 
FUEL-INJECTION PUMP
9 461 619 700 
NP-VE4/10F2100RNP1255 
 
FUEL-INJECTION PUMP
Back to top