104640-4160 ZEXEL 9 461 610 642 BOSCH FUEL-INJECTION PUMP 9461610642 1046404160


 

Information fuel-injection pump

BOSCH 9 461 610 642 9461610642
ZEXEL 104640-4160 1046404160
104640-4160 FUEL-INJECTION PUMP
Rating:
44
Buy FUEL-INJECTION PUMP 104640-4160 zexel genuine, new aftermarket engine parts with delivery

Include in #2:

104740-4160 as FUEL INJECTION PUMP

Cross reference number

Zexel num
Bosch num
Firm num
Name
104640-4160 
9 461 610 642 
NP-VE4/10F2100RNP112 
   
FUEL-INJECTION PUMP
Q




Information:

Battery
9S1990 BATTERY CHARGER TESTER.The storage battery circuit represents a continuous, although variable, electrical load to the charging unit. If the circuit, positive or negative is opened or broken while the charging unit is charging, the loss of the battery load will result in the charging voltage rising to unsafe levels.High voltage will damage the charging unit and regulator and may damage other electrical components or instruments.NEVER DISCONNECT ANY CHARGING UNIT CIRCUIT OR BATTERY CIRCUIT CABLE FROM BATTERY WHEN THE CHARGING UNIT IS PRODUCING A CHARGE.A load test should be made on a battery that discharges very rapidly when in use. To do this apply a resistance of three times the ampere/hour rating of the battery across the battery main terminals. Allow the resistance to discharge the battery for 15 seconds and immediately test the battery voltage. A 12 volt battery in good condition will test 9 volts.The instructions included with the 9S1990 Battery Charger Tester completely covers the battery testing subject.Starting System
Use a D.C. voltmeter to locate starting system components which do not function.Turn the disconnect switch ON. Attach one voltmeter lead to the starter solenoid terminal connected to both a cable and a small wire. Ground the other voltmeter lead. No voltmeter reading indicates a defective disconnect switch. A voltmeter reading of battery voltage indicates further testing is necessary.Turn the HEAT-START switch to the START position. Starting motor solenoid operation is audible as the starter motor pinion engages with the ring gear on the engine flywheel. The solenoid operation should also close the electric circuit to the motor. Attach one voltmeter lead to the solenoid terminal that is connected to the motor. Ground the other lead. Turn the HEAT-START switch to START and observe the voltmeter. A battery voltage reading indicates the malfunction is in the motor. It must be removed for further testing. No voltmeter reading indicates that the solenoid contacts do not close and the solenoid must be repaired or the starter pinion clearance should be adjusted.A starting motor solenoid that will not operate may not be receiving battery current. Attach one lead of the voltmeter to the solenoid battery cable connection. Ground the other lead. No voltmeter reading indicates a defective disconnect switch. A voltmeter reading indicates further testing is necessary.Continue the test by attaching one voltmeter lead to the starting motor solenoid small wire terminal and the other lead to ground. Observe the voltmeter and turn the HEAT-START switch to START. A voltmeter reading indicates that the malfunction is in the solenoid. No voltmeter reading indicates that either the circuit breaker is defective or the HEAT-START switch does not close when turned to the START position.Attach one lead of the voltmeter to the HEAT-START switch battery wire terminal and ground the other lead. A voltmeter reading indicates a defective switch. No voltmeter reading indicates the circuit breaker points are open. If the circuit breaker reset button will not close the points the circuit breaker is defective.A starting motor that operates too slow can

Have questions with 104640-4160?





Group cross 104640-4160 ZEXEL

9 461 610 641 
 
FUEL-INJECTION PUMP
9 461 624 072 
 
FUEL-INJECTION PUMP
104640-4160  
9 461 610 642 
NP-VE4/10F2100RNP112 
 
FUEL-INJECTION PUMP
9 461 625 021 
 
FUEL-INJECTION PUMP
9 461 625 022 
 
FUEL-INJECTION PUMP
9 461 622 602 
NP-VE4/10F2100RNP115 
 
FUEL-INJECTION PUMP