104640-3100 ZEXEL 9 461 616 645 BOSCH FUEL-INJECTION PUMP 9461616645 1046403100


 

Information fuel-injection pump

BOSCH 9 461 616 645 9461616645
ZEXEL 104640-3100 1046403100
104640-3100 FUEL-INJECTION PUMP
Rating:
51
Buy FUEL-INJECTION PUMP 104640-3100 zexel genuine, new aftermarket engine parts with delivery

Include in #2:

104740-3180 as FUEL INJECTION PUMP

Cross reference number

Zexel num
Bosch num
Firm num
Name
104640-3100 
9 461 616 645 
NP-VE4/10F2100RNP178 
   
FUEL-INJECTION PUMP
Q




Information:

Above Normal Heating Recommended Procedure
1. Low Coolant Level ... If the coolant level is too low, not enough coolant will go through the engine and radiator. This lack of coolant will not take enough heat from the engine and there will not be enough flow of coolant through the radiator to release the heat into the cooling air. Low coolant level is caused by leaks or wrong filling of the radiator. With the engine cool, be sure that coolant can be seen at the low end of the fill neck on the radiator top tank.2. Bad Temperature Gauge ... A temperature gauge which does not work correctly will not show the correct temperature. If the temperature gauge shows that the coolant temperature is too hot but other conditions are normal, either install a gauge you know is good or check the cooling system with the 9S9102 Thermistor Thermometer Group.3. Dirty Radiator ... Check the radiator for debris between the fins of the radiator core which prevents free air flow through the radiator core. Check the radiator for debris, dirt, or deposits on the inside of the radiator core which prevents free flow of coolant through the radiator.4. Loose Belt(s) ... Loose fan or water pump belts will cause a reduction in air or water flow. Tighten the belts according to V-BELT TENSION CHART that is shown in Specification section of this Service Manual.5. Bad Hose(s) ... Bad hoses with leaks can normally be seen. Hoses that have no visual leaks can "collapse" (pull together) during operation and cause a restriction in the flow of coolant. Hoses become soft and/or get cracks after a period of time. Hoses must be changed after 50,000 miles or a year of use. The inside can become loose, and the loose particles of the hose can cause a restriction in the flow of coolant.6. Shunt Line Restriction ... A restriction of the shunt line from the radiator top tank to the engine front cover, or a shunt line not installed correctly, will cause a reduction in water pump efficiency. The result will be low coolant flow and overheating.7. Shutters Not Opening Correctly ... Check the opening temperature of the shutters. The shutters must be completely closed at a temperature below the fully open temperature of the water temperature regulators.8. Bad Water Temperature Regulators ... A regulator that does not open, or only opens part of the way, can cause above normal heating. To test the thermostats, see the Testing and Adjusting section of this Service Manual.9. Bad Water Pump ... A water pump with a loose pulley or impeller does not pump enough coolant for correct engine cooling. A loose pulley or impeller can be found by removing the drive belt for the water pump, and by pushing the pulley back and pulling it forward. If the pulley or impeller is not loose, remove the water pump and check for damage to the impeller. If the impeller has no damage, check the

Have questions with 104640-3100?





Group cross 104640-3100 ZEXEL

104640-3100  
9 461 616 645 
NP-VE4/10F2100RNP178 
 
FUEL-INJECTION PUMP
9 461 610 634 
 
FUEL-INJECTION PUMP
9 461 625 014 
NP-VE4/10F2100RNP111 
 
FUEL-INJECTION PUMP
9 461 610 635 
NP-VE4/10F2100RNP30 
 
FUEL-INJECTION PUMP
9 461 610 636 
NP-VE4/10F2100RNP76 
 
FUEL-INJECTION PUMP
9 461 612 390 
NP-VE4/10F2100RNP148 
 
FUEL-INJECTION PUMP
9 461 610 002 
NP-VE4/10F2100RNP149 
 
FUEL-INJECTION PUMP
9 461 614 076 
NP-VE4/10F2100RNP172 
 
FUEL-INJECTION PUMP
9 461 622 201 
NP-VE4/10F2100RNP166 
 
FUEL-INJECTION PUMP