104600-9022 ZEXEL 9 461 623 529 BOSCH FUEL-INJECTION PUMP 9461623529 1046009022


 

Information fuel-injection pump

BOSCH 9 461 623 529 9461623529
ZEXEL 104600-9022 1046009022
104600-9022 FUEL-INJECTION PUMP
Rating:
76
Buy FUEL-INJECTION PUMP 104600-9022 zexel genuine, new aftermarket engine parts with delivery

Include in #2:

104700-9022 as FUEL INJECTION PUMP

Cross reference number

Zexel num
Bosch num
Firm num
Name
104600-9022 
104600-9023 
9 461 623 529 
   
FUEL-INJECTION PUMP
* Q




Information:

Test 1 - Overspeed Switch (OS)
Table 1
Overspeed Switch (OS)
Step Engine RPM Action Correct Result
A 25 + 5 rpm less than 75% Overspeed Verify rpm Press the 75% Verify button No engine shutdown
B 25 + 5 rpm more than 75% Overspeed Verify rpm Press the 75% Verify button Air and fuel shutoff
C Manually reset the air shutoff lever at the top of the air inlet, if equipped. Press the ESS reset button. Test 2 - Emergency Stop Switch (ES)
Table 2
Emergency Stop Switch (ES)
Step Engine RPM Action Correct Result
A Any rpm above the crank terminate rpm Press the push button for the emergency stop switch Air and fuel shutoff
B Manually reset the air shutoff lever at the top of the air inlet, if equipped. Turn ES switch in the dirction that is shown on the face of the push button in order to reset the switch. Test 3 - Normal Stop Switch (NSS)
Table 3
Normal Stop Switch (NSS)
Step Engine RPM Action Correct Result
A Any rpm above the crank terminate rpm Push the normal stop switch (NSS) Fuel shutoff Test 4 - Water Temperature Contactor Switch
Table 4
Water Temperature Contactor Switch (WTS)
Step Engine RPM Action Correct Result
A Any rpm above the crank terminate rpm Place a jumper across terminals TS-2 and TS-7. Fuel shutoff
B Remove the jumper from terminals TS-2 and TS-7. Test 5 - Oil Pressure Switch (OPS1)
Table 5
Oil Pressure Switch (OPS1)
Step Engine RPM Action Correct Result
A Any rpm above the crank terminate rpm Place a jumper across terminals OPS1-1 and OPS1-3. Fuel shutoff
B Remove the jumper from terminals OPS1-1 and OPS1-3. Test 6 - Oil Pressure Switch (OPS2)
Table 6
Oil Pressure Switch (OPS2)
Step Engine RPM Action Correct Result
A 25 + 5 rpm less than the setting for the oil step speed Place a jumper across terminals OPS2-1 and OPS2-3. No engine shutdown.
B 25 + 5 rpm more than the setting for the oil step speed Place a jumper across terminals OPS2-1 and OPS2-3. Fuel shutoff 9 seconds after the oil step speed is reached.
C Remove the jumper from across terminals OPS2-1 and OPS2-3.

Have questions with 104600-9022?





Group cross 104600-9022 ZEXEL

9 461 623 527 
 
FUEL-INJECTION PUMP
9 461 623 528 
 
FUEL-INJECTION PUMP
104600-9022  

104600-9023 
9 461 623 529 
 
FUEL-INJECTION PUMP
9 461 624 715 
 
FUEL-INJECTION PUMP
9 461 627 897 
 
FUEL-INJECTION PUMP
9 461 626 347 
NP-VE4/10E2000RNP30 
 
FUEL-INJECTION PUMP
9 461 629 339 
NP-VE4/10E2000RNP30 
 
FUEL-INJECTION PUMP
Back to top