104294-2051 ZEXEL 9 410 617 279 BOSCH FUEL-INJECTION PUMP 9410617279 1042942051 8943658841


 

Information fuel-injection pump

BOSCH 9 410 617 279 9410617279
ZEXEL 104294-2051 1042942051
ISUZU 8943658841 8943658841
104294-2051 FUEL-INJECTION PUMP
Rating:
65
Buy FUEL-INJECTION PUMP 104294-2051 zexel genuine, new aftermarket engine parts with delivery

Components :

0. INJECTION-PUMP ASSEMBLY 104294-2051
1. _
2. FUEL INJECTION PUMP
3. NUMBER PLATE
4. _
5. CAPSULE
6. ADJUSTING DEVICE
7. NOZZLE AND HOLDER ASSY 105148-1001
8. Nozzle and Holder 8-94116-934-2
9. Open Pre:MPa(Kqf/cm2) 11.8{120}
10. NOZZLE-HOLDER 105078-0002
11. NOZZLE 105007-1010

Scheme ###:

5. [2] 140154-2120 PLUNGER-AND-BARREL ASSY
12. [2] 140110-4420 DELIVERY-VALVE ASSEMBLY
13. [2] 140112-1700 COMPRESSION SPRING
16. [2] 140115-1400 GASKET
17. [2] 140116-7600 FITTING
18. [2] 140117-1700 FILLER PIECE
20. [2] 016500-1520 O-RING
40. [2] 140200-1620 TAPPET
44. [2] 140212-0300 BEARING PIN
45. [1] 140213-0400 WIRE
50. [2] 140215-1900 COMPRESSION SPRING
51. [2] 140216-0800 SLOTTED WASHER
52. [2] 140217-2200 SLOTTED WASHER
53/1. [1] 140217-5000 PLATE D19T2.60
53/1. [1] 140217-5100 PLATE D19T2.65
53/1. [1] 140217-5200 PLATE D19T2.70
53/1. [1] 140217-5300 PLATE D19T2.75
53/1. [1] 140217-5400 PLATE D19T2.80
53/1. [1] 140217-5500 PLATE D19T2.85
53/1. [1] 140217-5600 PLATE D19T2.90
53/1. [1] 140217-5700 PLATE D19T2.95
53/1. [1] 140217-5800 PLATE D19T3.00
53/1. [1] 140217-5900 PLATE D19T3.05
53/1. [1] 140217-6000 PLATE D19T3.10
53/1. [1] 140217-6100 PLATE D19T3.15
53/1. [1] 140217-6200 PLATE D19T3.20
53/1. [1] 140217-6300 PLATE D19T3.25
53/1. [1] 140217-6400 PLATE D19T3.30
53/1. [1] 140217-6500 PLATE D19T3.35
53/1. [1] 140217-6600 PLATE D19T3.40
53/1. [1] 140217-6700 PLATE D19T3.45
53/1. [1] 140217-6800 PLATE D19T3.50
53/1. [1] 140217-6900 PLATE D19T3.55
53/1. [1] 140217-7000 PLATE D19T3.60
53/1. [1] 140217-7100 PLATE D19T3.65
53/1. [1] 140217-7200 PLATE D19T3.70
53/1. [1] 140217-7300 PLATE D19T3.75
53/1. [1] 140217-7400 PLATE D19T3.80
53/1. [1] 140217-7500 PLATE D19T3.85
53/1. [1] 140217-7600 PLATE D19T3.90
53/1. [1] 140217-7700 PLATE D19T3.95
53/1. [1] 140217-7800 PLATE D19T4.00
53/1. [1] 140217-7900 PLATE D19T4.05
53/1. [1] 140217-8000 PLATE D19T4.10
53/1. [1] 140253-2000 PLATE
53/1. [1] 140253-2100 PLATE
53/1. [1] 140253-2200 PLATE
53/1. [1] 140253-2300 PLATE
53/1. [1] 140253-2400 PLATE
53/1. [1] 140253-2500 PLATE
53/1. [1] 140253-2600 PLATE
53/1. [1] 140253-2700 PLATE
53/1. [1] 140253-2800 PLATE
53/1. [1] 140253-2900 PLATE
53/1. [1] 140253-3000 PLATE
53/1. [1] 140253-3100 PLATE
53/1. [1] 140253-3200 PLATE
53/1. [1] 140253-3300 PLATE
53/1. [1] 140253-3400 PLATE
53/1. [1] 140253-3500 PLATE
53/1. [1] 140253-3600 PLATE
53/1. [1] 140253-3700 PLATE
53/1. [1] 140253-3800 PLATE
53/1. [1] 140253-3900 PLATE
53/1. [1] 140253-4000 PLATE
53/1. [1] 140253-4100 PLATE
53/1. [1] 140253-4200 PLATE
53/1. [1] 140253-4300 PLATE
53/1. [1] 140253-4400 PLATE
53/1. [1] 140253-4500 PLATE
53/1. [1] 140253-4600 PLATE
53/1. [1] 140253-4700 PLATE
53/1. [1] 140253-4800 PLATE
53/1. [1] 140253-4900 PLATE
60. [1] 140243-3320 CONTROL RACK
77. [2] 140241-2700 CONTROL SLEEVE
93. [1] 140402-2000 EYE BOLT
94. [2] 026512-1540 GASKET D15.4&12.2T1.50
110. [1] 140420-1400 BLEEDER SCREW
111. [1] 026508-1240 GASKET D11.9&8.2T1
156. [1] 140255-0000 BEARING PIN
157. [1] 029320-6010 LOCKING WASHER
158. [1] 140256-0300 COVER
159. [1] 010735-1020 FLAT-HEAD SCREW M5P0.9L10

Include in #2:

104294-2051 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
104294-2051 
9 410 617 279 
NP-PFR2KD55/2NP22 
8943658841  ISUZU
FUEL-INJECTION PUMP
K 23DB FUEL INJECTION PUMP PFR-2KD PFR




Information:

Changing Filter Element
A 1U-9578 Repair Kit (Nozzle Tester) is available to maintain the tester. The repair kit contains a new filter along with seals, gaskets, and instructions on how to use the kit. Do not reuse seals and gaskets when changing the filter. Always use new seals and gaskets.Calibration Fluid
The calibration fluid should be changed every three months or after testing 50 nozzles. The fluid should also be changed whenever inaccurate test results are suspected.Inaccurate test results can be caused by fluid with improper specific gravity, viscosity, visible contamination, fluid that foams, or discolored fluid.The fluid should also be checked for the correct viscosity. It is a good practice to test new calibration fluid for the correct viscosity and specific gravity. Use a 9U-7840 Test Kit to check calibration fluid.
Do not refill the nozzle tester with test oil that has been pumped through a fuel injection nozzle. Nozzles contain residual amounts of diesel fuel that is pumped out when tested. The diesel fuel mixes with and contaminates the test oil. Using this diesel fuel test oil combination will damage the nozzle tester.
9U-7840 Test Kit For Checking Fluid Viscosity Calibration fluid will last longer if the nozzles are cleaned prior to testing. As the fluid in the tester becomes contaminated, the accuracy of the test results are decreased.Changing Calibration Fluid
1. Completely drain the reservoir and any fluid contained in the pump mechanism. Special care must be taken for the disposal of the calibration fluid. Recent regulations prohibit the dumping of oil; all oil must be properly disposed.2. Thoroughly clean the reservoir using an 8T-9011 Component Cleaner or equivalent and clean towels.3. Install a new 8T-5313 Filter Element (10 micron). A new filter element should be installed whenever the calibration fluid is changed (even if less than 3 months).4. Fill the reservoir with clean calibration fluid (refer to the chart for part numbers).Nozzle Tester Pressure Gauges
Pressure gauges in the nozzle tester should be checked for accuracy every 12 months or whenever inaccurate test results are suspected. Gauges should also be checked whenever a gauge is damaged or the needle does not return to zero. Record all data on the data sheets in the "Forms" section.1. Remove pressure gauge from the nozzle tester.2. Install gauge adapter from 5P-8558 Calibrating Group Pressure Gauge onto pressure gauge.3. Connect pressure to tester port.4. Use a 1U-5230 Hand Pump to apply pressure to the gauge. Increase the pressure to 25% of the pressure gauges capacity.5. Check the actual gauge pressure with the tester gauge reading. The two pressures should be within two percent of each other.6. Repeat Step 5 at 50, 75 and 100 percent increments. Each increment should be within two percent of the tester gauge reading.7. If the pressure is not within two percent, the pressure gauge should be replaced.Check Tester For Leakage
Before testing any nozzle, check the tester for obvious external leakage. Leakage in the tester will give inaccurate test results, causing good nozzles to be rejected.Always check the tester for leakage

Have questions with 104294-2051?





Group cross 104294-2051 ZEXEL

Isuzu 

 
5156101390 
FUEL-INJECTION PUMP
 
5156101392 
FUEL-INJECTION PUMP
 
5156101393 
FUEL-INJECTION PUMP
 
8944079580 
FUEL-INJECTION PUMP
 
8944079581 
FUEL-INJECTION PUMP
9 410 617 028 
NP-PFR2KD55/2NP15 
8944079582 
FUEL-INJECTION PUMP
 
8941365490 
FUEL-INJECTION PUMP
 
8941365492 
FUEL-INJECTION PUMP
 
8944079590 
FUEL-INJECTION PUMP
9 410 618 329 
NP-PFR2KD55/2NP18 
8944079591 
FUEL-INJECTION PUMP
 
 

Isuzu 

9 410 617 278 
NP-PFR2KD55/2NP20 
8944779361 
FUEL-INJECTION PUMP
9 410 618 330 
NP-PFR2KD55/2NP21 
8944779350 
FUEL-INJECTION PUMP
 
8943658840 
FUEL-INJECTION PUMP
104294-2051  
9 410 617 279 
NP-PFR2KD55/2NP22 
8943658841 
FUEL-INJECTION PUMP
Back to top