Information fuel-injection pump
BOSCH
9 410 617 137
9410617137
ZEXEL
104266-4054
1042664054

Rating:
Components :
0. | INJECTION-PUMP ASSEMBLY | 104266-4054 |
1. | _ | |
2. | FUEL INJECTION PUMP | |
3. | NUMBER PLATE | |
4. | _ | |
5. | CAPSULE | |
6. | ADJUSTING DEVICE | |
7. | NOZZLE AND HOLDER ASSY | |
8. | Nozzle and Holder | |
9. | Open Pre:MPa(Kqf/cm2) | |
10. | NOZZLE-HOLDER | |
11. | NOZZLE |
Scheme ###:
5. | [1] | 141176-4921 | PLUNGER-AND-BARREL ASSY |
7. | [2] | 141133-0500 | CAPSULE |
7. | [2] | 141133-0500 | CAPSULE |
8. | [2] | 141403-1300 | GASKET |
8. | [2] | 141403-1300 | GASKET |
12. | [1] | 141145-4721 | DELIVERY-VALVE ASSEMBLY |
17. | [1] | 141138-1700 | FITTING |
20. | [1] | 141118-2000 | O-RING |
21. | [1] | 141119-3600 | FLANGE BUSHING |
22. | [6] | 141124-1300 | BLEEDER SCREW |
25. | [1] | 141482-9600 | O-RING |
50. | [1] | 141215-7101 | COMPRESSION SPRING |
51. | [1] | 141216-1800 | SLOTTED WASHER |
52. | [1] | 141217-5500 | SLOTTED WASHER |
53. | [1] | 141218-7920 | GUIDE |
55. | [1] | 141220-1200 | LOCKING WASHER |
60. | [1] | 141244-9400 | CONTROL RACK |
77. | [1] | 141292-1500 | CONTROL SLEEVE |
81. | [1] | 141245-2000 | POINTER |
82/1. | [0] | 023500-6210 | PLAIN WASHER D11&6.4T1.5 |
82/1. | [0] | 029300-6010 | PLAIN WASHER D11&6.4T0.8 |
82/1. | [0] | 029300-6020 | PLAIN WASHER D11&6.4T0.35 |
83. | [1] | 020006-1440 | BLEEDER SCREW M6P1L14 |
110. | [1] | 141420-0800 | BLEEDER SCREW |
111. | [1] | 141421-0000 | GASKET |
153. | [1] | 029112-6020 | CAPSULE |
154. | [1] | 141403-1600 | GASKET |
160. | [1] | 141418-1400 | SET OF NUTS |
161. | [1] | 141107-0700 | GASKET |
Include in #1:
101491-9702
as _
Include in #2:
104266-4054
as INJECTION-PUMP ASSEMBLY
Cross reference number
Zexel num
Bosch num
Firm num
Name
Information:
Introduction
The problem that is identified below does not have a permanent solution. Until a permanent solution is known, use the solution that is listed below.Problem
A significant amount of HEUI pumps and injectors have been returned, but no cause of failure can be determined.Solution
Diagnostic procedures have been updated and have been incorporated into the following publications:
Special Instruction, REHS3819, "Procedure for Troubleshooting and Cleaning the Oil Rail System for the Hydraulic Electronic Unit Injector (HEUI)"
Troubleshooting, "Injection Actuation Pressure - Test"Note: These publications have been translated into Mandarin and Spanish.In addition, a new troubleshooting checklist is included with all service repair for HUEI pumps and HEUI injectors. The checklist is a summary of the diagnostic procedure steps to be confirmed before a suspect component is replaced. The checklist must be completed and returned with the suspect components in order to aid engineering to determine the cause of failure.Following the instructions step-by-step is critical in order to diagnose the failed component correctly. Do not skip steps in the procedures. Skipping steps in the procedure will lead to incorrect diagnosis of the problem.
The problem that is identified below does not have a permanent solution. Until a permanent solution is known, use the solution that is listed below.Problem
A significant amount of HEUI pumps and injectors have been returned, but no cause of failure can be determined.Solution
Diagnostic procedures have been updated and have been incorporated into the following publications:
Special Instruction, REHS3819, "Procedure for Troubleshooting and Cleaning the Oil Rail System for the Hydraulic Electronic Unit Injector (HEUI)"
Troubleshooting, "Injection Actuation Pressure - Test"Note: These publications have been translated into Mandarin and Spanish.In addition, a new troubleshooting checklist is included with all service repair for HUEI pumps and HEUI injectors. The checklist is a summary of the diagnostic procedure steps to be confirmed before a suspect component is replaced. The checklist must be completed and returned with the suspect components in order to aid engineering to determine the cause of failure.Following the instructions step-by-step is critical in order to diagnose the failed component correctly. Do not skip steps in the procedures. Skipping steps in the procedure will lead to incorrect diagnosis of the problem.