104265-4061 ZEXEL 9 410 617 630 BOSCH FUEL-INJECTION PUMP 9410617630 1042654061 e326450030az


 

Information fuel-injection pump

BOSCH 9 410 617 630 9410617630
ZEXEL 104265-4061 1042654061
DAIHATSU E326450030AZ e326450030az
104265-4061 FUEL-INJECTION PUMP
Rating:
83
Buy FUEL-INJECTION PUMP 104265-4061 zexel genuine, new aftermarket engine parts with delivery

Components :

0. INJECTION-PUMP ASSEMBLY 104265-4061
1. _
2. FUEL INJECTION PUMP
3. NUMBER PLATE
4. _
5. CAPSULE
6. ADJUSTING DEVICE
7. NOZZLE AND HOLDER ASSY 105114-3060
8. Nozzle and Holder
9. Open Pre:MPa(Kqf/cm2) 29.4{300}
10. NOZZLE-HOLDER 105044-4021
11. NOZZLE 105012-0730

Scheme ###:

1. [1] 141053-5320 PUMP HOUSING
5. [1] 141176-2920 PLUNGER-AND-BARREL ASSY
7. [1] 141133-0500 CAPSULE
8. [1] 141403-1300 GASKET
12. [1] 141142-5220 DELIVERY-VALVE ASSEMBLY
20. [1] 141118-2000 O-RING
21. [1] 141119-4100 FLANGE BUSHING
22. [6] 141124-1300 BLEEDER SCREW
25. [1] 141482-9600 O-RING
50. [1] 141215-5402 COMPRESSION SPRING
51. [1] 141216-1800 SLOTTED WASHER
52. [1] 141217-5500 SLOTTED WASHER
53. [1] 141218-7920 GUIDE
55. [1] 141220-1200 LOCKING WASHER
60. [1] 141244-7800 CONTROL RACK
77. [1] 141241-7200 CONTROL SLEEVE
81. [1] 141245-2000 POINTER
82/1. [0] 023500-6210 PLAIN WASHER D11&6.4T1.5
82/1. [0] 029300-6010 PLAIN WASHER D11&6.4T0.8
82/1. [0] 029300-6020 PLAIN WASHER D11&6.4T0.35
83. [1] 020006-1440 BLEEDER SCREW M6P1L14
92. [1] 141401-2500 BUSHING
93. [1] 141402-2920 EYE BOLT
94. [2] 141403-1600 GASKET
110. [1] 140420-1600 BLEEDER SCREW
111. [1] 141403-1200 GASKET
160. [1] 141418-1400 SET OF NUTS
161. [1] 141403-1400 GASKET
162. [1] 141480-0900 COVER
163. [1] 150948-0000 INLET UNION
164. [1] 141402-3720 EYE BOLT
165. [2] 150934-0900 GASKET

Include in #1:

Include in #2:

104265-4061 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
104265-4061 
104265-4062 
9 410 617 630 
E326450030AZ  DAIHATSU
FUEL-INJECTION PUMP
* K




Information:

Procedure
Note: Prior to performing the analysis with the APC, be sure to read and understand all the interferences listed in the "Interferences Inherent In the Fuel Sample" section of this document. Ensure that all precautions have been taken to minimize the affect of skewed results due to improper sampling, handling, or preparation.
Obtain the fuel sample to be analyzed in an appropriate sample bottle as described in the "Fuel Sample Preparation" section. Manually or mechanically shake the sample vigorously for 30 seconds. When manually shaking a sample, ensure thorough mixing of the sample by turning the bottle so that the lid is facing downward. Shake by moving the wrist and/or forearm up and down as rapidly as is comfortable for the 30 seconds.Note: Degassing samples can be accomplished with either the use of an ultrasonic bath or with the use of a vacuum pump.
Immediately degas the sample, by partially opening the lid to the bottle and placing the sample upright in the degassing unit. Perform only one of the degassing methods. An ultrasonic bath is the best method for degassing a sample. An ultrasonic bath takes the least amount of time minimizing the impact of particle settling.Note: The purpose of partially unscrewing or opening the lid is to promote quick degassing of the sample. Air bubbles to remaining near the surface of the sample following the degassing process are acceptable.
Illustration 5 g01741117
If an ultrasonic bath is unavailable, an alternative method of degassing the sample is with the use of a 1U-5718 Oil Sampling Vacuum Pump. Ensure the 1U-5718 Oil Sampling Vacuum Pump is clean before beginning the degas process.Note: Rubber is to be placed over the hole of the tubing for the pump to develop and hold the required vacuum.
With the sample to be analyzed in the sample bottle, thread the bottle into the bottom of the 1U-5718 Oil Sampling Vacuum Group. Operate the pump to create a vacuum. Maintain the vacuum until all air bubbles have risen to the surface of the sample and dissipated.
If an ultrasonic bath or a vacuum pump is not available, the sample can degas naturally. Degas the sample by setting the sample on a flat surface and leaving the sample undisturbed. If the APC performs a flushing cycle, let the sample sit for 15 seconds. If the APC does not perform a flushing cycle, such as the 293-8413 HYDAC Contamination Monitor Group or the 383-4255 HYDAC Contamination Monitor Group, let the sample sit for 30 seconds. Proceed to the "Sample Processing" section.Sample Processing
Remove the lid from the sample bottle. Immediately begin the processing of the sample on the APC that has been prepared according to the "Fuel Sample Preparation" section.Note: If more than 45 seconds elapse after the shaking of the sample, the procedure shall be restarted with shaking of the sample in "Fuel Sample Preparation" section. Shaking the sample ensures that suspended particles do not settle to the bottom of the sample, causing inaccurate particle count results.
Obtain the particle count results

Have questions with 104265-4061?





Group cross 104265-4061 ZEXEL

Akasaka-Diesel 

 
001254229000 
FUEL-INJECTION PUMP
 
 
FUEL-INJECTION PUMP

Daihatsu 

 
E326450010Z 
FUEL-INJECTION PUMP
 
 

Akasaka-Diesel 

9 410 617 828 
001254253 
FUEL-INJECTION PUMP
9 410 617 829 
 
FUEL-INJECTION PUMP

Akasaka-Diesel 

9 410 618 268 
NP-PF1GX250A00N17 
001254253002 
FUEL-INJECTION PUMP

Daihatsu 

9 410 617 183 
E326450020AZ 
FUEL-INJECTION PUMP
9 410 617 629 
NP-PF1GX250A00N25 
E326450020BZ 
FUEL-INJECTION PUMP
104265-4061  

104265-4062 
9 410 617 630 
E326450030AZ 
FUEL-INJECTION PUMP
9 410 617 631 
NP-PF1GX250A00N26 
E326450030BZ 
FUEL-INJECTION PUMP
9 410 617 878 
E326450050ZZ 
FUEL-INJECTION PUMP
9 410 617 878 
E326450060AZ 
FUEL-INJECTION PUMP
9 410 617 632 
NP-PF1GX250A00N29 
E326450060BZ 
FUEL-INJECTION PUMP
9 410 617 879 
E326450050ZA 
FUEL-INJECTION PUMP
9 410 617 633 
NP-PF1GX250A00N30 
E326450050BZ 
FUEL-INJECTION PUMP
 
 
FUEL-INJECTION PUMP
 
 
FUEL-INJECTION PUMP
9 410 618 447 
NP-PF1GX250A00N33 
 
FUEL-INJECTION PUMP
Back to top