Information:

Operation Description:Power to the ECM can fail due to an open circuit in the wire, or a blown fuse. A fuse is blown out as a result of an overloaded circuit. For example, the +battery connection is shorted to ground.Test Step 1. CHECK THE ECM FOR POWER AND GROUND.At the ECM, measure the voltage from contact 1 to contact 2. Expected Result:The voltage is system voltage.Results:
OK - The voltage is system voltage. The power supply circuit to the ECM is correct. STOP
NOT OK - The voltage is not system voltage. Proceed to Test Step 2.Test Step 2. CHECK THE FUSEWhenever the machine's electronic components fail to function, check the appropriate fuse for the ECM.
Check the fuse for the ECM.Expected Result:The fuse is correct.Results:
YES - The fuse is correct. Proceed to Test Step 3.
NO - The fuse is not correct.Repair: Replace the blown fuse or reset the circuit breaker. Observe the machine for a recurrence of the problem. If the problem persists, the reason for the blown fuse must be isolated and corrected.STOPTest Step 3. CHECK THE POWER WIRE TO THE ECM.
Turn the key start switch and the disconnect switch to the OFF position.
At the fuse, connect the lead from the multimeter to wire 113-RD.
At the ECM, connect the other lead from the multimeter to connector contact 1 and measure the resistance.Expected Result:The resistance is less than 5 ohms.Results:
OK - The resistance is less than 5 ohms. The wiring circuit is correct. Proceed to Test Step 4.
NOT OK - The resistance measurement is greater than 5000 ohms. The wiring has an open circuit.Repair: Repair the wiring harness or replace the wiring harness. STOPTest Step 4. CHECK THE ECM GROUND CONNECTIONS.
The keyswitch and the disconnect switch remain in the OFF position.
At the ECM, measure the resistance from connector contact 2 to frame ground.Expected Result:The resistance is less than 5 ohms.Results:
OK - The resistance is less than 5 ohms. The ground circuit is correct. The ECM may have failed. This is unlikely. Perform this entire procedure again. If the problem remains, the ECM may need to be replaced. Contact your dealerships for possible consultation with Caterpillar. This consultation may greatly reduce repair time.STOP
NOT OK - The resistance is greater than 5000 ohms. The ground circuit has failed.Repair: The ground circuit has failed. Repair the wiring harness or replace the wiring harness.STOP

Have questions with 104264-5042?





Group cross 104264-5042 ZEXEL

 
 

Fuji-Diesel 

 
A34610 
FUEL-INJECTION PUMP
 
A34610D 
FUEL-INJECTION PUMP

Yokota 

9 410 618 264 
NP-PF1GX240A03N6 
3A10228 
FUEL-INJECTION PUMP

Akasaka-Diesel 

9 410 617 823 
NP-PF1GX240A03N16 
001254252001 
FUEL-INJECTION PUMP

Fuji-Diesel 

104264-5042  
9 410 618 265 
NP-PF1GX240A03N24 
A35203A 
FUEL-INJECTION PUMP
104264-5042  
9 410 618 265 
NP-PF1GX240A03N24 
A35203B 
FUEL-INJECTION PUMP
 
6S27F2 
FUEL-INJECTION PUMP
9 410 617 868 
NP-PF1GX240A03N38 
A35716 
FUEL-INJECTION PUMP

Akasaka-Diesel 

9 410 617 824 
001254266000 
FUEL-INJECTION PUMP
9 410 617 825 
001254272001 
FUEL-INJECTION PUMP
9 410 617 243 
NP-PF1GX240A03N39 
001254272002 
FUEL-INJECTION PUMP
 
 

Daihatsu 

 
E286430010AZ 
FUEL-INJECTION PUMP
9 410 617 628 
NP-PF1GX240A03N49 
E286430010BZ 
FUEL-INJECTION PUMP
9 410 617 244 
NP-PF1GX240A03N54 
 
FUEL-INJECTION PUMP
Back to top