104213-0032 ZEXEL 9 410 617 126 BOSCH FUEL-INJECTION PUMP 9410617126 1042130032


 

Information fuel-injection pump

BOSCH 9 410 617 126 9410617126
ZEXEL 104213-0032 1042130032
104213-0032 FUEL-INJECTION PUMP
Rating:
49
Buy FUEL-INJECTION PUMP 104213-0032 zexel genuine, new aftermarket engine parts with delivery

Components :

0. INJECTION-PUMP ASSEMBLY 104213-0032
1. _
2. FUEL INJECTION PUMP
3. NUMBER PLATE
4. _
5. CAPSULE
6. ADJUSTING DEVICE
7. NOZZLE AND HOLDER ASSY
8. Nozzle and Holder
9. Open Pre:MPa(Kqf/cm2) 27.5{280}
10. NOZZLE-HOLDER 105094-3042
11. NOZZLE 105016-4450

Scheme ###:

5. [1] 141174-5020 PLUNGER-AND-BARREL ASSY
7. [1] 141106-8300 CAPSULE
8. [1] 029331-2130 GASKET
12. [1] 141140-6520 DELIVERY-VALVE ASSEMBLY
13. [1] 141112-2000 COMPRESSION SPRING
16. [1] 141115-4600 GASKET
17. [1] 141126-2420 FITTING
20. [1] 029635-0020 O-RING
50. [1] 141215-2601 COMPRESSION SPRING
51. [1] 141216-1800 SLOTTED WASHER
52. [1] 141217-3000 SLOTTED WASHER
53. [1] 141218-5020 GUIDE
55. [1] 141220-1200 LOCKING WASHER
60. [1] 141244-1600 CONTROL RACK
61. [1] 141226-3200 BLEEDER SCREW
77. [1] 141241-2700 CONTROL SLEEVE
81. [1] 141245-2000 POINTER
82/1. [0] 023500-6210 PLAIN WASHER D11&6.4T1.5
82/1. [0] 029300-6010 PLAIN WASHER D11&6.4T0.8
82/1. [0] 029300-6020 PLAIN WASHER D11&6.4T0.35
83. [1] 020006-1440 BLEEDER SCREW M6P1L14
92. [1] 029702-6020 INLET UNION
93. [1] 029732-6010 EYE BOLT
94. [2] 026526-3440 GASKET
100. [1] 029762-6130 UNION NUT
101. [1] 029351-7010 PLAIN WASHER
110. [1] 141420-1600 BLEEDER SCREW
111. [1] 026506-1040 GASKET D9.9&6.2T1
160. [1] 141133-0200 CAPSULE
161. [1] 026516-2040 GASKET D19.9&16.2T1

Include in #2:

104213-0032 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
104213-0032 
104213-0033 
9 410 617 126 
   
FUEL-INJECTION PUMP
* K




Information:

Battery
Never disconnect any charging unit circuit or battery circuit cable from battery when the charging unit is operated. A spark can cause an explosion from the flammable vapor mixture of hydrogen and oxygen that is released from the electrolyte through the battery outlets. Injury to personnel can be the result.
The battery circuit is an electrical load on the charging unit. The load is variable because of the condition of the charge in the battery. Damage to the charging unit can result if the connections (either positive or negative) between the battery and charging unit are broken while the charging unit is in operation. This is because the battery load is lost and there is an increase in charging voltage. High voltage can damage, not only the charging unit, but also the regulator and other electrical components.Use the 6V4930 Battery Load Tester, the 8T0900 Clamp-On Ammeter and the 6V7070 Multimeter to load test a battery that does not hold a charge when in use. See Special Instruction, Form No. SEHS8268 for the correct procedure and specifications to use.Charging System
The condition of charge in the battery at each regular inspection will show if the charging system operates correctly. An adjustment is necessary when the battery is constantly in a low condition of charge or a large amount of water is needed (more than one ounce of water per cell per week or per every 100 service hours).When it is possible, make a test of the charging unit and voltage regulator on the engine, and use wiring and components that are a permanent part of the system. Off-engine (bench) testing will give a test of the charging unit and voltage regulator operation. This testing will give an indication of needed repair. After repairs are made, again make a test to give proof that the units are repaired to their original condition of operation.Before the start of on-engine testing, the charging system and battery must be checked as shown in the Steps that follow:1. Battery must be at least 75% (1.225 Sp.Gr.) fully charged and held tightly in place. The Battery holder must not put too much stress on the battery.2. Cables between the battery, starter and engine ground must be the correct size. Wires and cables must be free of corrosion and have cable support clamps to prevent stress on battery connections (terminals).3. Leads, junctions, switches, and panel instruments that have direct relation to the charging circuit must give correct circuit control.4. Inspect the drive components for the charging unit to be sure they are free of grease and oil and have the ability to operate the charging unit.Alternator Regulator Adjustment (Delco-Remy)
When an alternator is charging the battery too much or not enough, the charging rate of the alternator should be checked. Make reference to the Specifications module to find all testing specifications for the alternators and regulators.
5N5692 Alternator
(1) Ground terminal. (2) Pulley nut.No adjustment can be made to change the rate of charge on the alternator regulators. If rate of

Have questions with 104213-0032?





Group cross 104213-0032 ZEXEL

9 410 617 679 
NP-PF1GD230A00N27 
 
FUEL-INJECTION PUMP
9 410 617 680 
 
FUEL-INJECTION PUMP
9 410 617 681 
 
FUEL-INJECTION PUMP
104213-0032  

104213-0033 
9 410 617 126 
 
FUEL-INJECTION PUMP
9 410 617 913 
NP-PF1GD230A00N73 
 
FUEL-INJECTION PUMP
9 410 617 958 
NP-PF1GD230A00N87 
 
FUEL-INJECTION PUMP
 
 
FUEL-INJECTION PUMP
9 410 617 938 
NP-PF1GD230A00N106 
 
FUEL-INJECTION PUMP
 
 

9 410 618 005 
NP-PF1GD230A00N108 
 
FUEL-INJECTION PUMP
 
 

Back to top