104196-0112 ZEXEL 9 410 618 442 BOSCH FUEL-INJECTION PUMP 9410618442 1041960112


 

Information fuel-injection pump

BOSCH 9 410 618 442 9410618442
ZEXEL 104196-0112 1041960112
104196-0112 FUEL-INJECTION PUMP
Rating:
19
Buy FUEL-INJECTION PUMP 104196-0112 zexel genuine, new aftermarket engine parts with delivery

Components :

0. INJECTION-PUMP ASSEMBLY 104196-0112
1. _
2. FUEL INJECTION PUMP
3. NUMBER PLATE
4. _
5. CAPSULE
6. ADJUSTING DEVICE
7. NOZZLE AND HOLDER ASSY
8. Nozzle and Holder
9. Open Pre:MPa(Kqf/cm2)
10. NOZZLE-HOLDER
11. NOZZLE

Scheme ###:

1. [1] 141054-6600 PUMP HOUSING
5. [1] 141156-8520 PLUNGER-AND-BARREL ASSY
7. [1] 141106-6500 CAPSULE
8. [1] 029331-2090 GASKET D17&12.5T1
12. [1] 141140-2520 DELIVERY-VALVE ASSEMBLY
13. [1] 141112-3800 COMPRESSION SPRING
17. [1] 141126-9220 FITTING
17/1. [1] 141126-8200 FITTING
17/2. [1] 141117-5000 FILLER PIECE
17/3. [1] 141405-0300 CAPSULE
17/4. [1] 029330-8160 GASKET
20. [1] 029636-0070 O-RING
21. [1] 141119-3400 FLANGE BUSHING
22. [6] 141124-1000 BLEEDER SCREW
23. [1] 029635-0080 O-RING
50. [1] 141215-2200 COMPRESSION SPRING
51. [1] 141216-1500 SLOTTED WASHER
52. [1] 141217-4100 SLOTTED WASHER
53. [1] 141218-3020 GUIDE
55. [1] 141220-1800 LOCKING WASHER
60. [1] 141243-7600 CONTROL RACK
77. [1] 141241-4900 CONTROL SLEEVE
81. [1] 141245-1500 POINTER
82/1. [0] 141246-0000 SHIM D66&41.5T0.2
82/1. [0] 141246-0100 SHIM D66&41.5T0.5
82/1. [0] 141246-0200 SHIM D66&41.5T1.0
82/1. [0] 141246-0300 SHIM D66&41.5T3.2
83. [2] 012255-1620 FLAT-HEAD SCREW
87. [1] 029851-0020 HINGED LID
90. [2] 141400-0500 BUSHING
90. [2] 141400-0500 BUSHING
91. [2] 029331-6140 GASKET D22&16.1T1
91. [2] 029331-6140 GASKET D22&16.1T1
204. [1] 141010-2220 COVER
205. [1] 141011-0400 GASKET
206. [4] 029001-0280 BLEEDER SCREW
207. [1] 141040-0400 COVER
208. [1] 141041-0100 GASKET
209. [2] 029001-0280 BLEEDER SCREW
210. [1] 029428-0010 BEARING PIN

Include in #1:

Include in #2:

104196-0112 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
104196-0112 
9 410 618 442 
   
FUEL-INJECTION PUMP
K 24LB FUEL INJECTION PUMP PF-PC2-5 PF




Information:


Stopping the engine immediately after it has been working under load can result in overheating and accelerated wear of the engine components. Allow the engine to engine cool down before stopping. Avoiding hot engine shutdowns will maximize turbocharger shaft and bearing life.
Emergency Stopping
Emergency shutoff controls are for EMERGENCY use ONLY. DO NOT use emergency shutoff devices or controls for normal stopping procedure.
Make sure that any external system components that have been operating to support engine operation are secured after any stop.Emergency Stop Button
Emergency stop button, mounted on a junction box.Emergency stops may be made by pushing the Emergency Stop Button located on the junction box (if equipped). Both the button and the air inlet shutoff (if equipped) require resetting before the engine will start.Air Shutoff (If Equipped)
Some engines are equipped with an air shutoff, located between the aftercooler and the turbocharger. If equipped with an air shutoff lever, move the lever to the OFF position.Manual Stop Procedure
Stopping the engine immediately after it has been working under load, can result in overheating and accelerated wear of the engine components. Follow the stopping procedure, outlined below, to allow the engine to cool. Excessive temperatures in the turbocharger center housing will cause oil coking problems. Shutting the engine off without a cool down period does not allow the coolant temperature to stabilize, and may result in exhaust manifold cracking or leaking. Follow the stopping procedure outlined below to allow the engine to cool before shut down.
There may be several ways to shut off your engine. Make sure the shutoff procedures are understood. Use the following general guidelines for stopping the engine.1. Reduce engine speed to low idle.2. Shift into NEUTRAL.3. If the engine has been operated at low loads, run the engine at LOW IDLE for 30 seconds before stopping.If the engine has been operated at high load, increase engine speed to no more than 1/2 rated speed for three to five minutes to reduce and stabilize internal engine coolant and oil temperatures. Then reduce the engine speed to low idle before stopping.4. Check the marine transmission oil level while the engine is idling. Refer to the marine transmission OEM literature for lubrication maintenance recommendations.5. Follow your vessel's OEM instructions for stopping the engine with the pilot controls.A manual shutoff shaft is provided to override the governor control. The shaft can be used to move the fuel control linkage to the FUEL OFF position. The engine may be stopped by using the shaft and the mechanical governor control (if equipped).
Typical mechanical governor control.Move the mechanical governor control to the FUEL OFF position. Hold the control at the FUEL OFF position until the engine stops.After Stopping the Engine
Check the crankcase oil level. Maintain the oil level between the ADD and FULL marks on the dipstick.Repair any leaks, perform minor adjustments, tighten loose bolts, etc.Note the service hour meter reading. Perform periodic maintenance as instructed in the Maintenance Schedule.Fill the fuel tank to prevent accumulation of moisture in the fuel. Do not overfill.
Only

Have questions with 104196-0112?





Group cross 104196-0112 ZEXEL

Niigata-Urawa 

 
11247007C 
FUEL-INJECTION PUMP
 
11247001A 
FUEL-INJECTION PUMP

Niigata-Urawa 

 
11247001A 
FUEL-INJECTION PUMP

Niigata-Tekkou 

9 410 617 483 
11247007G 
FUEL-INJECTION PUMP

Ishikawajima 

9 410 618 441 
0121185 
FUEL-INJECTION PUMP
104196-0112  
9 410 618 442 
 
FUEL-INJECTION PUMP
 
 

 
 

 
 

Niigata-Urawa 

 
11247008A 
FUEL-INJECTION PUMP
 
11247008C 
FUEL-INJECTION PUMP

Niigata-Tekkou 

9 410 617 484 
11247008E 
FUEL-INJECTION PUMP
 
 

 
 

 
 

 
 

9 410 617 114 
 
FUEL-INJECTION PUMP
 
 
FUEL-INJECTION PUMP
 
 
FUEL-INJECTION PUMP
Back to top