Information fuel-injection pump
BOSCH
9 410 617 896
9410617896
ZEXEL
104194-3043
1041943043
NIIGATA-TEKKOU
V3K47210E
v3k47210e

Rating:
Components :
0. | INJECTION-PUMP ASSEMBLY | 104194-3043 |
1. | _ | |
2. | FUEL INJECTION PUMP | |
3. | NUMBER PLATE | |
4. | _ | |
5. | CAPSULE | |
6. | ADJUSTING DEVICE | |
7. | NOZZLE AND HOLDER ASSY | |
8. | Nozzle and Holder | |
9. | Open Pre:MPa(Kqf/cm2) | |
10. | NOZZLE-HOLDER | |
11. | NOZZLE |
Scheme ###:
1. | [1] | 141055-0620 | PUMP HOUSING |
5. | [1] | 141157-1620 | PLUNGER-AND-BARREL ASSY |
9. | [1] | 141118-2900 | O-RING |
12. | [1] | 141145-1122 | DELIVERY-VALVE ASSEMBLY |
12/1. | [1] | 141141-9500 | SEAT;D.V |
12/2. | [1] | 141138-1300 | FITTING |
12/3. | [1] | 141142-7300 | VALVE BODY |
12/4. | [1] | 141144-0300 | COMPRESSION SPRING |
12/5. | [1] | 141113-3400 | SLOTTED WASHER |
12/6. | [1] | 141145-8400 | VALVE BODY |
12/7. | [1] | 141112-8701 | COILED SPRING |
12/8. | [1] | 141113-3100 | SLOTTED WASHER |
12/9. | [2] | 010234-3520 | HEX-SOCKET-HEAD CAP SCREW |
20. | [1] | 141485-0800 | O-RING |
21. | [1] | 141482-9800 | O-RING |
22. | [6] | 141124-5000 | BLEEDER SCREW |
24. | [2] | 016421-0750 | BACKUP RING |
25. | [2] | 141485-0900 | O-RING |
50. | [1] | 141215-8700 | COMPRESSION SPRING |
51. | [1] | 141216-1200 | SLOTTED WASHER |
52. | [1] | 141217-8400 | SLOTTED WASHER |
53. | [1] | 141294-0002 | GUIDE |
55. | [1] | 141220-0700 | LOCKING WASHER |
60. | [1] | 141291-2601 | CONTROL RACK |
68. | [1] | 141405-3800 | CAPSULE |
69. | [1] | 141403-2100 | GASKET |
77. | [1] | 141292-3202 | CONTROL SLEEVE |
81. | [1] | 141245-2300 | POINTER |
82/1. | [0] | 023500-6210 | PLAIN WASHER D11&6.4T1.5 |
82/1. | [0] | 029300-6010 | PLAIN WASHER D11&6.4T0.8 |
82/1. | [0] | 029300-6020 | PLAIN WASHER D11&6.4T0.35 |
83. | [1] | 020006-1440 | BLEEDER SCREW M6P1L14 |
90. | [1] | 029112-2020 | CAPSULE |
91. | [1] | 026522-2740 | GASKET D26.9&22.2T1 |
93. | [2] | 141402-5021 | EYE BOLT |
93. | [2] | 141402-5021 | EYE BOLT |
110. | [1] | 141420-1500 | BLEEDER SCREW |
111. | [1] | 141403-1800 | GASKET |
160. | [1] | 141418-2600 | SET OF NUTS |
161. | [1] | 141403-2000 | GASKET |
163. | [2] | 029111-0140 | CAPSULE |
163. | [2] | 029111-0140 | CAPSULE |
164. | [2] | 026510-1340 | GASKET D13.4&10.2T1 |
164. | [2] | 026510-1340 | GASKET D13.4&10.2T1 |
167. | [1] | 150948-0000 | INLET UNION |
168. | [1] | 150949-0100 | EYE BOLT |
169. | [2] | 150521-0800 | GASKET |
170. | [1] | 029111-0140 | CAPSULE |
171. | [1] | 026510-1340 | GASKET D13.4&10.2T1 |
Include in #2:
104194-3043
as INJECTION-PUMP ASSEMBLY
Cross reference number
Zexel num
Bosch num
Firm num
Name
Information:
Introduction
The objective of this topic is to assist users in establishing a Preventive Maintenance Program for Standby Generator Sets or as an aid in evaluating their present programs.Standby Generator Sets may not be needed very often, but when they are, it is usually under emergency conditions. Maintenance of these standby units is very important. They must always be in excellent operating condition, ready to work under load at any time.Establishing a Preventive Maintenance Program will provide maximum availability of a standby generator set when needed, longer engine and generator life, and a minimum of expensive repairs.The recommended WEEKLY maintenance checks can be performed by an operator. The checks consist of basic maintenance requirements to ensure the standby generator set will be ready for immediate use should the need arise.All YEARLY and THREE YEAR maintenance should be performed by an authorized mechanic or your Caterpillar dealer. These checks and maintenance requirements will require that the standby generator be run under load conditions, and may require special test equipment.These guidelines are to be used with the information contained in the Operation and Maintenance sections of this manual. The Operation and Maintenance sections of the manual will provide the necessary information on how to perform the checks and routine maintenance.Refer to the Generator and Engine Service Manuals and Recommended Preventive Maintenance Schedules for Standby Generator Sets, SEBU6042 for additional information, or contact your Caterpillar dealer for assistance.Inspection and Maintenance Agreements
Your Caterpillar dealer can establish an Inspection and Preventive Maintenance Program for your generator set to provide maximum reliability, increased engine and generator life, and minimize expensive repairs. Contact your Caterpillar dealer for details.General Recommendations
Safety
The stop-manual-automatic switch on the cranking panel must be set at STOP position when performing maintenance or repair work on a standby generator set. This prevents the unit from starting if a power failure or voltage drop should occur while working on the unit.To prevent personal injury due to accidental starting of the engine, disconnect the batteries or disable the starting system before doing maintenance or repair work.Lock out all switch gear and automatic transfer switches associated with the generator while performing any generator maintenance or repairs. Make sure no shock hazard exists.Failure to comply could result in personal injury or death.
Always make repairs with the engine stopped and the starting system disabled. When servicing the generator, make sure that switch gear and automatic transfer switches will not present a shock hazard. Lock them out on the generator being serviced.Record Keeping
Maintain a log or record keeping system to document all gauge readings, problems, repairs, and maintenance performed on the equipment.Space Heaters
Moisture is a natural enemy of generators and all electrical equipment. Every effort must be made to keep the generator as dry as possible. Space heaters should be operated inside the generator when it is not in use to maintain the integrity of the generator windings.
The objective of this topic is to assist users in establishing a Preventive Maintenance Program for Standby Generator Sets or as an aid in evaluating their present programs.Standby Generator Sets may not be needed very often, but when they are, it is usually under emergency conditions. Maintenance of these standby units is very important. They must always be in excellent operating condition, ready to work under load at any time.Establishing a Preventive Maintenance Program will provide maximum availability of a standby generator set when needed, longer engine and generator life, and a minimum of expensive repairs.The recommended WEEKLY maintenance checks can be performed by an operator. The checks consist of basic maintenance requirements to ensure the standby generator set will be ready for immediate use should the need arise.All YEARLY and THREE YEAR maintenance should be performed by an authorized mechanic or your Caterpillar dealer. These checks and maintenance requirements will require that the standby generator be run under load conditions, and may require special test equipment.These guidelines are to be used with the information contained in the Operation and Maintenance sections of this manual. The Operation and Maintenance sections of the manual will provide the necessary information on how to perform the checks and routine maintenance.Refer to the Generator and Engine Service Manuals and Recommended Preventive Maintenance Schedules for Standby Generator Sets, SEBU6042 for additional information, or contact your Caterpillar dealer for assistance.Inspection and Maintenance Agreements
Your Caterpillar dealer can establish an Inspection and Preventive Maintenance Program for your generator set to provide maximum reliability, increased engine and generator life, and minimize expensive repairs. Contact your Caterpillar dealer for details.General Recommendations
Safety
The stop-manual-automatic switch on the cranking panel must be set at STOP position when performing maintenance or repair work on a standby generator set. This prevents the unit from starting if a power failure or voltage drop should occur while working on the unit.To prevent personal injury due to accidental starting of the engine, disconnect the batteries or disable the starting system before doing maintenance or repair work.Lock out all switch gear and automatic transfer switches associated with the generator while performing any generator maintenance or repairs. Make sure no shock hazard exists.Failure to comply could result in personal injury or death.
Always make repairs with the engine stopped and the starting system disabled. When servicing the generator, make sure that switch gear and automatic transfer switches will not present a shock hazard. Lock them out on the generator being serviced.Record Keeping
Maintain a log or record keeping system to document all gauge readings, problems, repairs, and maintenance performed on the equipment.Space Heaters
Moisture is a natural enemy of generators and all electrical equipment. Every effort must be made to keep the generator as dry as possible. Space heaters should be operated inside the generator when it is not in use to maintain the integrity of the generator windings.