104187-5000 ZEXEL 9 410 617 217 BOSCH FUEL-INJECTION PUMP 9410617217 1041875000


 

Information fuel-injection pump

BOSCH 9 410 617 217 9410617217
ZEXEL 104187-5000 1041875000
104187-5000 FUEL-INJECTION PUMP
Rating:
15
Buy FUEL-INJECTION PUMP 104187-5000 zexel genuine, new aftermarket engine parts with delivery

Components :

0. INJECTION-PUMP ASSEMBLY 104187-5000
1. _
2. FUEL INJECTION PUMP
3. NUMBER PLATE
4. _
5. CAPSULE
6. ADJUSTING DEVICE
7. NOZZLE AND HOLDER ASSY
8. Nozzle and Holder
9. Open Pre:MPa(Kqf/cm2)
10. NOZZLE-HOLDER
11. NOZZLE

Scheme ###:

1. [1] 141055-8120 PUMP HOUSING
5. [1] 141174-3920 PLUNGER-AND-BARREL ASSY
5/4. [2] 016420-1800 BACKUP RING
5/5. [3] 141485-6100 O-RING
7. [1] 141133-4300 CAPSULE
8. [1] 016500-7050 O-RING
9. [2] 016420-0700 BACKUP RING
10. [6] 014111-2440 LOCKING WASHER D21.5&12.2T3
11. [6] 010212-3540 HEX-SOCKET-HEAD CAP SCREW
13. [1] 141112-9800 COMPRESSION SPRING
17. [1] 141138-2520 FITTING
18. [8] 141124-6100 BLEEDER SCREW
19. [1] 016420-1900 BACKUP RING
20. [1] 141485-6200 O-RING
22. [8] 141124-4300 BLEEDER SCREW
50. [1] 141215-9200 COMPRESSION SPRING
51. [1] 141216-7200 SLOTTED WASHER
52. [1] 141217-9700 SLOTTED WASHER
53. [1] 141294-0800 GUIDE
55. [1] 141220-3400 LOCKING WASHER
56. [1] 141261-2100 SPACER BUSHING
57. [1] 016111-0520 LOCKING WASHER
60. [1] 141291-5800 CONTROL RACK
77. [1] 141292-4200 CONTROL SLEEVE
81. [2] 141245-3200 POINTER
82/1. [0] 029310-6220 SHIM D11.5&6.5T0.10
82/1. [0] 029310-6230 SHIM D11.5&6.5T0.20
82/1. [0] 029310-6240 SHIM D11.5&6.5T0.25
82/1. [0] 029310-6250 SHIM D11.5&6.5T1.00
82/1. [0] 029310-6370 SHIM D11.5&6.5T0.30
82/1. [0] 029310-6380 SHIM D11.5&6.5T0.40
82/1. [0] 029310-6390 SHIM D11.5&6.5T0.50
82/1. [0] 029310-6400 SHIM D11.5&6.5T0.60
82/1. [0] 029310-6410 SHIM D11.5&6.5T0.70
82/1. [0] 029310-6420 SHIM D11.5&6.5T0.80
82/1. [0] 029310-6430 SHIM D11.5&6.5T0.90
82/1. [0] 139406-0500 SHIM D11.5&6.5T1.5
82/1. [0] 139406-0600 SHIM D11.5&6.5T2.0
83. [1] 020006-1440 BLEEDER SCREW M6P1L14
90. [1] 141405-5000 CAPSULE
91. [1] 141403-2400 GASKET
155. [1] 141405-5200 CAPSULE
160. [1] 141418-2701 SET OF NUTS
161. [1] 141403-1600 GASKET
185. [1] 141458-0401 ADAPTOR
186. [1] 016500-2050 O-RING
190. [1] 141406-1500 GASKET
195. [1] 141231-1020 SLIDING PIECE
196. [1] 141227-0000 GASKET
197. [4] 014110-8420 LOCKING WASHER
198. [4] 010208-3520 HEX-SOCKET-HEAD CAP SCREW

Include in #2:

104187-5000 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
104187-5000 
104187-5001 
9 410 617 217 
   
FUEL-INJECTION PUMP
* K




Information:


Stopping the engine immediately after it has been working under load can result in overheating and accelerated wear of the engine components. Follow the stopping procedures, outlined below, to allow the engine to cool. Excessive temperatures in the turbocharger center housing will cause oil coking problems.
Prior to stopping an engine that is being operated at low loads, run the engine at LOW IDLE for 30 seconds before stopping. If the engine is being operated at high load, then it should be run at LOW IDLE for five minutes to reduce and stabilize internal engine coolant and oil temperatures before stopping.Make sure the Engine Stopping procedure is understood. The engine may be shutdown in several ways. To manually stop the engine, refer to the following information and instructions.Emergency Stop Procedure
The Emergency Stop Pushbutton (ESPB) and Emergency stop controls are for EMERGENCY use ONLY. DO NOT use for normal stopping procedure. Emergency Stop controls should only be used when an emergency exists, and not used to routinely stop the engine. Do NOT start the engine until the problem necessitating the emergency stop has been located and corrected.
* Emergency stops may be made through the Emergency Stop Pushbutton (ESPB). If the need for emergency engine shutdown occurs, push the EMERGENCY STOP Pushbutton located on the control panel or the engine junction box. This will activate the air and/or fuel shutoffs. Reset the EMERGENCY STOP Pushbutton (pull out and rotate the button in the direction indicated on the button). Some EMERGENCY STOP Pushbuttons can be pulled out to reset, not requiring any rotation.Manual Stop Procedure
1. Reduce the engine speed to LOW IDLE. Shift the marine transmission to NEUTRAL and secure the vessel.2. Increase engine speed to no more than half engine speed for five minutes to cool the engine. Reduce engine speed to LOW IDLE. 3. Check the crankcase oil level while the engine is idling. Maintain the oil level between the ADD and FULL marks on the CHECK WITH ENGINE RUNNING or ENGINE AT LOW IDLE WITH OIL WARM side of the dipstick.4. Shift the marine transmission to FORWARD or REVERSE. Check the marine transmission oil level at ENGINE AT LOW IDLE WITH OIL WARM. Maintain oil level between the ADD and FULL marks on the dipstick. Shift the marine transmission back to NEUTRAL.5. The engine may be stopped by using one of the following engine mounted controls.Toggle Switch
Move OEM or customer supplied toggle switch to the OFF position to shut off the fuel shutoff solenoid.Manual Fuel Shutoff Lever (All Engines)
Do not use the emergency shutoff control for a normal stopping procedure. A manual shutdown shaft is provided to override the governor solenoid. This shutdown will only move the fuel control linkage to the fuel OFF position to starve the engine of fuel. It does not shut off the air inlet. The engine will coast to a stop. Be sure to secure any external system components that have been operating to support the engine operation.After Stopping the Engine
1. If freezing temperatures

Have questions with 104187-5000?





Group cross 104187-5000 ZEXEL

104187-5000  

104187-5001 
9 410 617 217 
 
FUEL-INJECTION PUMP
 
 
FUEL-INJECTION PUMP
 
 
FUEL-INJECTION PUMP
 
 
FUEL-INJECTION PUMP
 
 

 
 

 
 

 
 

 
 

 
 

9 410 618 335 
NP-PF1FX760B03N4 
 
FUEL-INJECTION PUMP
Back to top