103086-0060 ZEXEL 9 410 612 943 BOSCH FUEL-INJECTION PUMP 9410612943 1030860060


 

Information fuel-injection pump

BOSCH 9 410 612 943 9410612943
ZEXEL 103086-0060 1030860060
103086-0060 FUEL-INJECTION PUMP
Rating:
19
Buy FUEL-INJECTION PUMP 103086-0060 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 133050-9120 PUMP HOUSING
1/30. [3] 029040-6020 STUD
1/35A. [1] 132400-0900 ADAPTOR
1/40. [1] 131400-0100 ADAPTOR
1/40A. [1] 131423-0200 ADAPTOR
1/41. [1] 026518-2240 GASKET D21.9&18.2T1
2. [1] 133010-6820 COVER
2/2. [1] 133011-0500 GASKET
3. [3] 133017-0900 FLAT-HEAD SCREW
5. [3] 029340-8010 GASKET D12&8T1.00
16. [8] 133034-0400 CAPSULE
19. [3] 029300-6030 PLAIN WASHER D11&6.4T0.5
20. [3] 014110-6410 LOCKING WASHER
21. [3] 013020-6020 UNION NUT M6P1H5
23. [1] 133041-0400 GASKET
30. [8] 133151-5220 PLUNGER-AND-BARREL ASSY
31. [8] 133106-0100 CAPSULE
32. [8] 029330-8110 GASKET D13&8.2T1.5
36. [8] 133110-2920 DELIVERY-VALVE ASSEMBLY
37. [8] 134112-0100 COILED SPRING
40. [8] 134115-0100 GASKET
41. [8] 133116-2600 FITTING
42. [8] 029632-5030 O-RING
43. [8] 133117-0200 FILLER PIECE
45. [4] 133122-1420 PLATE
55. [8] 133200-0220 TAPPET
55/2. [1] 133204-0200 ROLLER
55/3. [1] 133205-0200 BUSHING
55/4. [1] 133203-0300 BEARING PIN
55/5. [1] 133202-0100 HEXAGON SCREW
55/6. [1] 133201-0101 UNION NUT
61. [8] 133215-0400 COMPRESSION SPRING
62. [8] 133216-0100 SLOTTED WASHER
63. [8] 133217-0300 SLOTTED WASHER
67. [1] 133258-1000 CONTROL RACK
68. [1] 132226-0400 FLAT-HEAD SCREW
76. [8] 133240-0100 PINION
77. [8] 133241-0200 CONTROL SLEEVE
78. [8] 131242-0100 FLAT-HEAD SCREW
90. [1] 133380-0400 CAMSHAFT
91. [1] 016650-3030 BEARING PLATE
91A. [1] 016650-3030 BEARING PLATE
92. [1] 133302-0100 SPACER RING
92A. [1] 133302-0100 SPACER RING
93/1. [0] 029312-6010 SHIM D40&26T0.1
93/1. [0] 029312-6020 SHIM D40&26T0.12
93/1. [0] 029312-6030 SHIM D40&26T0.14
93/1. [0] 029312-6040 SHIM D40&26T0.16
93/1. [0] 029312-6050 SHIM D40&26T0.18
93/1. [0] 029312-6060 SHIM D40&26T0.5
93A/1. [0] 029312-6010 SHIM D40&26T0.1
93A/1. [0] 029312-6020 SHIM D40&26T0.12
93A/1. [0] 029312-6030 SHIM D40&26T0.14
93A/1. [0] 029312-6040 SHIM D40&26T0.16
93A/1. [0] 029312-6050 SHIM D40&26T0.18
93A/1. [0] 029312-6060 SHIM D40&26T0.5
95. [1] 133305-0300 BEARING SHELL
96. [2] 010208-4040 HEX-SOCKET-HEAD CAP SCREW
97. [2] 023500-8120 PLAIN WASHER
98. [2] 023650-8310 LOCKING WASHER
99. [2] 029630-9020 O-RING
100. [1] 029622-5010 PACKING RING
100A. [1] 029622-5010 PACKING RING
101. [1] 133316-4500 COVER
101A. [1] 133316-4201 COVER
104A. [4] 029010-8020 BLEEDER SCREW
105A. [4] 014110-8410 LOCKING WASHER
106A. [1] 029637-2000 O-RING
107A. [1] 156612-6300 COUPLING PLATE
110. [1] 029201-8020 UNION NUT
110A. [1] 029201-8020 UNION NUT
111. [1] 014111-8410 LOCKING WASHER
111A. [1] 014111-8410 LOCKING WASHER
112. [1] 025805-1910 WOODRUFF KEY
112A. [1] 025805-1910 WOODRUFF KEY
115. [1] 154007-0500 ADAPTOR
117A. [1] 029111-8010 CAPSULE M18P1.5L12
118A. [1] 026518-2240 GASKET D21.9&18.2T1
131. [1] 029731-4570 EYE BOLT
131A. [1] 133424-0221 OVER FLOW VALVE
133. [2] 029341-4130 GASKET D20&13.8T2*
133A. [2] 029341-4130 GASKET D20&13.8T2*
152. [1] 133430-0120 EYE BOLT
154. [2] 029341-4130 GASKET D20&13.8T2*
210. [1] 134430-0200 EYE BOLT
212. [2] 029341-0110 GASKET
360A. [1] 133245-0500 POINTER
361A. [2] 010535-0840 FLAT-HEAD SCREW M5P0.8L8
362A. [2] 014110-5440 LOCKING WASHER

Include in #1:

103864-0100 as FUEL INJECTION PUMP

Cross reference number

Zexel num
Bosch num
Firm num
Name
103086-0060 
9 410 612 943 
NP-PE8Z140D400LS8NP200 
   
FUEL-INJECTION PUMP
Q




Information:

Introduction
The objective of this topic is to assist users in establishing a Preventive Maintenance Program for Standby Generator Sets or as an aid in evaluating their present programs.Standby Generator Sets may not be needed very often, but when they are, it is usually under emergency conditions. Maintenance of these standby units is very important. They must always be in excellent operating condition, ready to work under load at any time.Establishing a Preventive Maintenance Program will provide maximum availability of a standby generator set when needed, longer engine and generator life, and a minimum of expensive repairs.The recommended WEEKLY maintenance checks can be performed by an operator. The checks consist of basic maintenance requirements to ensure the standby generator set will be ready for immediate use should the need arise.All YEARLY and THREE YEAR maintenance should be performed by an authorized mechanic or your Caterpillar dealer. These checks and maintenance requirements will require that the standby generator be run under load conditions, and may require special test equipment.These guidelines are to be used with the information contained in the Operation and Maintenance sections of this manual. The Operation and Maintenance sections of the manual will provide the necessary information on how to perform the checks and routine maintenance.Refer to the Generator and Engine Service Manuals and Recommended Preventive Maintenance Schedules for Standby Generator Sets, SEBU6042 for additional information, or contact your Caterpillar dealer for assistance.Inspection and Maintenance Agreements
Your Caterpillar dealer can establish an Inspection and Preventive Maintenance Program for your generator set to provide maximum reliability, increased engine and generator life, and minimize expensive repairs. Contact your Caterpillar dealer for details.General Recommendations
Safety
The stop-manual-automatic switch on the cranking panel must be set at STOP position when performing maintenance or repair work on a standby generator set. This prevents the unit from starting if a power failure or voltage drop should occur while working on the unit.To prevent personal injury due to accidental starting of the engine, disconnect the batteries or disable the starting system before doing maintenance or repair work.Lock out all switch gear and automatic transfer switches associated with the generator while performing any generator maintenance or repairs. Make sure no shock hazard exists.Failure to comply could result in personal injury or death.
Always make repairs with the engine stopped and the starting system disabled. When servicing the generator, make sure that switch gear and automatic transfer switches will not present a shock hazard. Lock them out on the generator being serviced.Record Keeping
Maintain a log or record keeping system to document all gauge readings, problems, repairs, and maintenance performed on the equipment.Space Heaters
Moisture is a natural enemy of generators and all electrical equipment. Every effort must be made to keep the generator as dry as possible. Space heaters should be operated inside the generator when it is not in use to maintain the integrity of the generator windings.

Have questions with 103086-0060?