Information fuel-injection pump
BOSCH
9 410 611 024
9410611024
ZEXEL
103068-8270
1030688270
Rating:
Scheme ###:
1. | [1] | 133051-0120 | PUMP HOUSING |
1/30. | [3] | 029040-6020 | STUD |
1/35. | [1] | 132400-0400 | ADAPTOR |
1/35A. | [1] | 132400-0400 | ADAPTOR |
2. | [1] | 133010-2720 | COVER |
2/2. | [1] | 133011-0900 | GASKET |
3. | [8] | 020106-1240 | BLEEDER SCREW M6P1.0L12 |
6. | [4] | 013020-6040 | UNION NUT M6P1H5 |
6. | [4] | 013020-6040 | UNION NUT M6P1H5 |
7. | [1] | 133021-0300 | COVER |
8. | [2] | 014110-6410 | LOCKING WASHER |
10. | [2] | 139006-0300 | STUD |
16. | [6] | 133034-0100 | CAPSULE |
20. | [3] | 014110-6410 | LOCKING WASHER |
21. | [3] | 013020-6020 | UNION NUT M6P1H5 |
23. | [1] | 133041-0400 | GASKET |
24. | [6] | 029633-4010 | O-RING |
30. | [6] | 133101-8720 | PLUNGER-AND-BARREL ASSY |
31. | [6] | 133106-0500 | CAPSULE |
32. | [6] | 026510-1340 | GASKET D13.4&10.2T1 |
36. | [6] | 133110-2320 | DELIVERY-VALVE ASSEMBLY |
37. | [6] | 133112-0600 | COMPRESSION SPRING |
40. | [6] | 133115-1200 | GASKET |
41. | [6] | 133116-3020 | DAMPING VALVE |
42. | [6] | 029632-5090 | O-RING |
45. | [6] | 133122-1000 | PLATE |
47. | [3] | 023650-8310 | LOCKING WASHER |
48. | [3] | 020728-2520 | STUD |
49. | [3] | 029300-8010 | PLAIN WASHER D15&8T1.00 |
50. | [3] | 013020-8040 | UNION NUT M8P1.25H7 |
51. | [3] | 133120-0100 | BUSHING |
52. | [6] | 029632-0020 | O-RING |
55. | [6] | 133200-1120 | TAPPET |
55/2. | [1] | 133201-0101 | UNION NUT |
55/3. | [1] | 133202-0100 | HEXAGON SCREW |
55/4. | [1] | 133203-0400 | BEARING PIN |
55/5. | [1] | 133204-0300 | ROLLER |
55/6. | [1] | 133205-0300 | BUSHING |
57. | [6] | 133210-0200 | FLAT-HEAD SCREW |
58. | [6] | 026510-1340 | GASKET D13.4&10.2T1 |
61. | [6] | 133215-0300 | COMPRESSION SPRING |
62. | [6] | 133216-0200 | SLOTTED WASHER |
63. | [6] | 133217-0100 | SLOTTED WASHER |
67. | [1] | 133256-0200 | CONTROL RACK |
68. | [1] | 133226-0600 | FLAT-HEAD SCREW |
69. | [1] | 023700-8120 | TAB WASHER |
76. | [6] | 133240-0100 | PINION |
77. | [6] | 133241-0200 | CONTROL SLEEVE |
78. | [6] | 131242-0100 | FLAT-HEAD SCREW |
90. | [1] | 133371-1300 | CAMSHAFT |
91. | [1] | 016603-3230 | BEARING PLATE |
91A. | [1] | 016603-3230 | BEARING PLATE |
92. | [1] | 133302-0200 | SPACER RING |
92A. | [1] | 133302-0200 | SPACER RING |
93/1. | [0] | 029313-0010 | SHIM D45&30.2T0.1 |
93/1. | [0] | 029313-0020 | SHIM D45&30.2T0.12 |
93/1. | [0] | 029313-0030 | SHIM D45&30.2T0.14 |
93/1. | [0] | 029313-0040 | SHIM D45&30.2T0.16 |
93/1. | [0] | 029313-0050 | SHIM D45&30.2T0.18 |
93/1. | [0] | 029313-0060 | SHIM D45&30.2T0.5 |
93/1. | [0] | 029313-0070 | SHIM D45&30.2T1 |
93A/1. | [0] | 029313-0010 | SHIM D45&30.2T0.1 |
93A/1. | [0] | 029313-0020 | SHIM D45&30.2T0.12 |
93A/1. | [0] | 029313-0030 | SHIM D45&30.2T0.14 |
93A/1. | [0] | 029313-0040 | SHIM D45&30.2T0.16 |
93A/1. | [0] | 029313-0050 | SHIM D45&30.2T0.18 |
93A/1. | [0] | 029313-0060 | SHIM D45&30.2T0.5 |
93A/1. | [0] | 029313-0070 | SHIM D45&30.2T1 |
95. | [1] | 133306-0200 | BEARING SHELL |
96. | [2] | 010208-4040 | HEX-SOCKET-HEAD CAP SCREW |
97. | [2] | 029630-9020 | O-RING |
98. | [2] | 023500-8120 | PLAIN WASHER |
99. | [2] | 023650-8310 | LOCKING WASHER |
100. | [1] | 133315-0000 | PACKING RING |
100A. | [1] | 133315-0000 | PACKING RING |
101. | [1] | 133316-0900 | COVER |
101A. | [1] | 133316-0900 | COVER |
104. | [6] | 010208-2020 | HEX-SOCKET-HEAD CAP SCREW |
104A. | [3] | 010208-2020 | HEX-SOCKET-HEAD CAP SCREW |
105. | [3] | 023650-8310 | LOCKING WASHER |
105A. | [6] | 023650-8310 | LOCKING WASHER |
108. | [1] | 029637-6010 | O-RING |
108A. | [1] | 029637-6010 | O-RING |
110. | [1] | 023012-0040 | UNION NUT M20P1.5H16 |
111. | [1] | 014112-0440 | LOCKING WASHER |
112. | [1] | 025806-2210 | WOODRUFF KEY |
113A. | [1] | 133328-0820 | CAP |
114A. | [3] | 021308-3520 | FLAT-HEAD SCREW |
117. | [1] | 029111-8020 | CAPSULE |
117A. | [1] | 027418-3240 | EYE BOLT |
118. | [1] | 026518-2240 | GASKET D21.9&18.2T1 |
118A. | [2] | 026518-2240 | GASKET D21.9&18.2T1 |
121. | [1] | 029111-0020 | CAPSULE |
122. | [1] | 026510-1340 | GASKET D13.4&10.2T1 |
130. | [1] | 029111-2020 | CAPSULE |
130A. | [1] | 029111-2020 | CAPSULE |
132. | [1] | 026512-1540 | GASKET D15.4&12.2T1.50 |
132A. | [1] | 026512-1540 | GASKET D15.4&12.2T1.50 |
136. | [1] | 029111-2020 | CAPSULE |
136A. | [1] | 029111-2020 | CAPSULE |
138. | [1] | 026512-1640 | GASKET D15.9&12.2T1 |
138A. | [1] | 026512-1640 | GASKET D15.9&12.2T1 |
145. | [1] | 029111-2070 | CAPSULE M12P1.5L10 |
146. | [1] | 026512-1540 | GASKET D15.4&12.2T1.50 |
152. | [1] | 029731-6030 | EYE BOLT |
153. | [1] | 133431-0920 | CONNECTOR |
154. | [2] | 026516-2040 | GASKET D19.9&16.2T1 |
198. | [1] | 027412-2440 | EYE BOLT |
199. | [2] | 026512-1540 | GASKET D15.4&12.2T1.50 |
204. | [1] | 133494-0320 | VALVE BODY |
207. | [1] | 026516-2040 | GASKET D19.9&16.2T1 |
400. | [1] | 133520-0000 | BUSHING |
402. | [1] | 029901-3020 | CAPSULE |
406. | [1] | 154352-2600 | CAPSULE |
407. | [1] | 026516-2040 | GASKET D19.9&16.2T1 |
410. | [1] | 133328-1300 | PLATE |
Cross reference number
Zexel num
Bosch num
Firm num
Name
103068-8270
9 410 611 024
FUEL-INJECTION PUMP
* Q
* Q
Information:
You must read and understand the warnings and instructions contained in the Safety section of this manual before performing any operation or maintenance procedures.Before proceeding with Every 1000 Hour maintenance, perform all previous maintenance interval requirements.Engine Protection Devices
Inspect for Proper Operation
Refer to the Service Manual for the procedure. All engine protective devices must be checked and maintained to provide the engine with proper protection if a component malfunction or failure should occur. Check all engine protective devices. Never use the Emergency Shutdown controls for a normal stopping procedure.SR4 Generator and Control Panel (If Equipped)
SR4 Generator
Before working inside the generator, make sure that the starting motor can not be activated by any automatic or manual signal.When the engine-generator is operating, voltages up to 600V are present in these areas near or on the regulator: 1. the regulator terminal strip2. the excitation transformer terminal strip (self-excited generator only)Do not short these terminals to ground with any part of the body or any conductive material. Loss of life or injury could result from electrical shock or injury from molten metal.
Electronic components in the regulator can be damaged during generator operation if contact is made between the part and ground.
Clean/Inspect Voltage Regulator
If moisture is allowed to remain in contact with an electrical winding, some of the moisture will eventually be absorbed. This will lower the resistance of the winding insulation. The insulation used on the windings of Caterpillar generators is moisture resistant, but constant exposure to moisture will gradually lower the insulation's resistance.Dirt can make the problem worse because it can hold the moisture in contact with the insulation. Salt (from coastal location sea air) can also make the problem much worse. This is because salt tends to absorb moisture from the air. When the salt and moisture combine, they make a good electrical conductor.* Clean the voltage regulator and generator of dirt and debris. Use a brush to loosen accumulations of dirt and a vacuum system for removal. Use of compressed air is not recommended, because of moisture present in the form of condensate.Carbon tracking on insulators can be caused by dirt or loose connections. These carbon paths must be cleaned or the insulators replaced. Failure to correct a carbon tracking problem will eventually result in a short in the electrical circuit.* Visually check for loose or broken wires and connections. Check the wires and connections on the regulator assembly. Check all wires and connections in the generator. Make any necessary repairs to the wiring as required.Visually inspect the generator and control panel. Check for loose, broken, or damaged wiring or components. The inspection only takes a few minutes and could avert a potential problem that could cause your generator set to fail.Operational Checks
Start the engine. Use the starting procedure found in the SR4 Generators and Control Panels Operation and Maintenance Manual, SEBU6150.The following operational checks include: * generator operation and engine starting* lubricating and fuel systems* overall operationThe checks should take no longer than five minutes to complete. A
Inspect for Proper Operation
Refer to the Service Manual for the procedure. All engine protective devices must be checked and maintained to provide the engine with proper protection if a component malfunction or failure should occur. Check all engine protective devices. Never use the Emergency Shutdown controls for a normal stopping procedure.SR4 Generator and Control Panel (If Equipped)
SR4 Generator
Before working inside the generator, make sure that the starting motor can not be activated by any automatic or manual signal.When the engine-generator is operating, voltages up to 600V are present in these areas near or on the regulator: 1. the regulator terminal strip2. the excitation transformer terminal strip (self-excited generator only)Do not short these terminals to ground with any part of the body or any conductive material. Loss of life or injury could result from electrical shock or injury from molten metal.
Electronic components in the regulator can be damaged during generator operation if contact is made between the part and ground.
Clean/Inspect Voltage Regulator
If moisture is allowed to remain in contact with an electrical winding, some of the moisture will eventually be absorbed. This will lower the resistance of the winding insulation. The insulation used on the windings of Caterpillar generators is moisture resistant, but constant exposure to moisture will gradually lower the insulation's resistance.Dirt can make the problem worse because it can hold the moisture in contact with the insulation. Salt (from coastal location sea air) can also make the problem much worse. This is because salt tends to absorb moisture from the air. When the salt and moisture combine, they make a good electrical conductor.* Clean the voltage regulator and generator of dirt and debris. Use a brush to loosen accumulations of dirt and a vacuum system for removal. Use of compressed air is not recommended, because of moisture present in the form of condensate.Carbon tracking on insulators can be caused by dirt or loose connections. These carbon paths must be cleaned or the insulators replaced. Failure to correct a carbon tracking problem will eventually result in a short in the electrical circuit.* Visually check for loose or broken wires and connections. Check the wires and connections on the regulator assembly. Check all wires and connections in the generator. Make any necessary repairs to the wiring as required.Visually inspect the generator and control panel. Check for loose, broken, or damaged wiring or components. The inspection only takes a few minutes and could avert a potential problem that could cause your generator set to fail.Operational Checks
Start the engine. Use the starting procedure found in the SR4 Generators and Control Panels Operation and Maintenance Manual, SEBU6150.The following operational checks include: * generator operation and engine starting* lubricating and fuel systems* overall operationThe checks should take no longer than five minutes to complete. A
Have questions with 103068-8270?
Group cross 103068-8270 ZEXEL
103068-8270
9 410 611 024
FUEL-INJECTION PUMP