Information fuel-injection pump
BOSCH
9 410 612 780
9410612780
ZEXEL
101067-0510
1010670510

Rating:
Scheme ###:
1. | [1] | 131070-0120 | PUMP HOUSING |
1/30. | [3] | 029040-6020 | STUD |
1/35. | [1] | 131400-0100 | ADAPTOR |
1/40A. | [1] | 131420-0420 | BLEEDER SCREW |
2. | [1] | 131013-5120 | COVER |
3. | [2] | 131017-1000 | FLAT-HEAD SCREW |
5. | [2] | 029340-6020 | GASKET D10&6.5T1.00 |
15. | [1] | 131030-3620 | LEVEL INDICATOR |
16. | [6] | 131034-1401 | CAPSULE |
21. | [3] | 139206-0400 | UNION NUT |
23. | [1] | 029633-1010 | O-RING |
30. | [6] | 131151-4320 | PLUNGER-AND-BARREL ASSY |
36. | [6] | 131110-0520 | DELIVERY-VALVE ASSEMBLY |
37. | [6] | 131112-0600 | COILED SPRING |
40. | [6] | 131115-0200 | GASKET |
41. | [6] | 131116-0400 | FITTING |
45. | [3] | 131122-0520 | PLATE |
55. | [6] | 131200-0620 | TAPPET |
55/2. | [1] | 131201-0100 | UNION NUT |
55/3. | [1] | 131202-0100 | HEXAGON SCREW |
55/4. | [1] | 131203-0200 | BEARING PIN |
55/5. | [1] | 131204-1000 | ROLLER |
55/6. | [1] | 131205-0500 | BUSHING |
55/7. | [1] | 131206-0200 | SLIDER |
61. | [6] | 131215-0600 | COMPRESSION SPRING |
62. | [6] | 131216-0100 | SLOTTED WASHER |
63. | [6] | 131217-0100 | SLOTTED WASHER |
67. | [1] | 131256-0000 | CONTROL RACK |
68. | [1] | 131226-0300 | FLAT-HEAD SCREW |
76. | [6] | 131240-0100 | PINION |
77. | [6] | 131241-0100 | CONTROL SLEEVE |
78. | [6] | 131242-0100 | FLAT-HEAD SCREW |
90. | [1] | 131370-0200 | CAMSHAFT |
91. | [1] | 016630-2640 | BEARING PLATE |
91A. | [1] | 028001-7010 | BEARING PLATE |
92. | [1] | 131302-0400 | SPACER RING |
92A. | [1] | 131302-0600 | SPACER RING |
93/1. | [0] | 029311-7010 | SHIM D22&17T0.1 |
93/1. | [0] | 029311-7020 | SHIM D22&17T0.12 |
93/1. | [0] | 029311-7030 | SHIM D22&17T0.14 |
93/1. | [0] | 029311-7040 | SHIM D22&17T0.16 |
93/1. | [0] | 029311-7050 | SHIM D22&17T0.18 |
93/1. | [0] | 029311-7060 | SHIM D22&17T0.5 |
93/1. | [0] | 029311-7070 | SHIM D22&17T1.0 |
93/1. | [0] | 029311-7090 | SHIM D22&17T0.3 |
93/1. | [0] | 029311-7210 | SHIM D22&17T0.7 |
93/1. | [0] | 029311-7220 | SHIM D22&17T1.4 |
93/1. | [0] | 139417-0000 | SHIM D22&17T2.4 |
93A/1. | [0] | 029311-7010 | SHIM D22&17T0.1 |
93A/1. | [0] | 029311-7020 | SHIM D22&17T0.12 |
93A/1. | [0] | 029311-7030 | SHIM D22&17T0.14 |
93A/1. | [0] | 029311-7040 | SHIM D22&17T0.16 |
93A/1. | [0] | 029311-7050 | SHIM D22&17T0.18 |
93A/1. | [0] | 029311-7060 | SHIM D22&17T0.5 |
93A/1. | [0] | 029311-7070 | SHIM D22&17T1.0 |
93A/1. | [0] | 029311-7090 | SHIM D22&17T0.3 |
93A/1. | [0] | 029311-7210 | SHIM D22&17T0.7 |
93A/1. | [0] | 029311-7220 | SHIM D22&17T1.4 |
93A/1. | [0] | 139417-0000 | SHIM D22&17T2.4 |
95. | [1] | 131306-0800 | BEARING SHELL |
96. | [2] | 029050-5010 | FLAT-HEAD SCREW M5P0.8L32 |
97. | [2] | 026505-0940 | GASKET |
100. | [1] | 029621-7020 | PACKING RING |
101. | [1] | 131330-2300 | COVER |
104. | [4] | 020006-1440 | BLEEDER SCREW M6P1L14 |
106. | [1] | 029634-4020 | O-RING |
107. | [1] | 156612-4500 | COUPLING PLATE |
110. | [1] | 013021-2140 | UNION NUT M12P1.75H10 |
111. | [1] | 023641-2410 | LOCKING WASHER |
112. | [1] | 025803-1610 | WOODRUFF KEY |
117. | [1] | 029731-4080 | EYE BOLT |
118. | [2] | 139514-0100 | GASKET |
121. | [1] | 131400-0800 | CAPSULE |
122. | [1] | 139510-0100 | GASKET |
145. | [1] | 155406-0220 | AIR FILTER |
152. | [1] | 029731-0470 | EYE BOLT |
153. | [1] | 029711-0080 | INLET UNION |
154. | [2] | 029341-0020 | GASKET |
Cross reference number
Zexel num
Bosch num
Firm num
Name
Information:
Remote Fault Reset$00 $0D aUsed to reset faults on the CCM.
Table 2
(a)     $00 - $7F = Retain current CCM inactive fault status.
$80 - $FF = Reset CCM inactive fault.    Device ID Code$00 $80 aabbccUsed to read the device ID code from the CCM as well as other components on the data link. Each pair of bytes (aa, bb, cc) is sent LSB first.
Table 3
(aa)     Module ID: will always equal $61, data will be sent as $61 $00    
(bb)     Service Tool Support Change Level: $01, data will be sent as $01 $00    
(cc)     Application type:$FF $E0, data will be sent as $E0 $FF    CCM Error Codes$00 $82 abUsed to read the CCM Error Codes.
Table 4
(a)     bit 1 = Reserved    
(b) (1)     Fault Code Status    
bit 8     1 = RS-232C link message fault exists    
bit 7     1 = Miscellaneous Cat Data Link fault    
bit 6     1 = Invalid Cat Data message fault    
bit 5     1 = Internal buffer overflow on RS-232C or Data Data Link fault    
bit 4     1 = RS-232C short circuit fault    
bit 3     1 = Memory battery is weak    
bit 2     1 = M5X message error (checksum or byte count error)    
bit 1     1 = EEPROM fault    
( 1 ) A value of 0 (zero) in bits 1 through 8 indicates that particular fault does not exist.CCM Communication Rate Change Enable$AA $12 aUsed to determine if the CCM is connected to the host computer directly or remotely using a modem. Also used to enable or disable the host computers ability to change the communication rate of the RS-232C serial port.
Table 5
(a)     Bit 4     Reserved for Caterpillar.    
Bit 3 0 = Enable password protection
1 = Disable password protection    
Bit 2 0 = Enable baud rate change
1 = Disable baud rate change    
Bit 1 0 = Direct connection
1 = Modem connection    Access Level 1 Password$AA $87 aaaaaaaaUsed to read or program the Level 1 Password
Table 6
(aaaaaaaa)     Level 1 password in printable ASCII form. Must be at least 6, but no more than
Table 2
(a)     $00 - $7F = Retain current CCM inactive fault status.
$80 - $FF = Reset CCM inactive fault.    Device ID Code$00 $80 aabbccUsed to read the device ID code from the CCM as well as other components on the data link. Each pair of bytes (aa, bb, cc) is sent LSB first.
Table 3
(aa)     Module ID: will always equal $61, data will be sent as $61 $00    
(bb)     Service Tool Support Change Level: $01, data will be sent as $01 $00    
(cc)     Application type:$FF $E0, data will be sent as $E0 $FF    CCM Error Codes$00 $82 abUsed to read the CCM Error Codes.
Table 4
(a)     bit 1 = Reserved    
(b) (1)     Fault Code Status    
bit 8     1 = RS-232C link message fault exists    
bit 7     1 = Miscellaneous Cat Data Link fault    
bit 6     1 = Invalid Cat Data message fault    
bit 5     1 = Internal buffer overflow on RS-232C or Data Data Link fault    
bit 4     1 = RS-232C short circuit fault    
bit 3     1 = Memory battery is weak    
bit 2     1 = M5X message error (checksum or byte count error)    
bit 1     1 = EEPROM fault    
( 1 ) A value of 0 (zero) in bits 1 through 8 indicates that particular fault does not exist.CCM Communication Rate Change Enable$AA $12 aUsed to determine if the CCM is connected to the host computer directly or remotely using a modem. Also used to enable or disable the host computers ability to change the communication rate of the RS-232C serial port.
Table 5
(a)     Bit 4     Reserved for Caterpillar.    
Bit 3 0 = Enable password protection
1 = Disable password protection    
Bit 2 0 = Enable baud rate change
1 = Disable baud rate change    
Bit 1 0 = Direct connection
1 = Modem connection    Access Level 1 Password$AA $87 aaaaaaaaUsed to read or program the Level 1 Password
Table 6
(aaaaaaaa)     Level 1 password in printable ASCII form. Must be at least 6, but no more than