101041-9070 ZEXEL 9 410 610 608 BOSCH FUEL-INJECTION PUMP 9410610608 1010419070


 

Information fuel-injection pump

BOSCH 9 410 610 608 9410610608
ZEXEL 101041-9070 1010419070
101041-9070 FUEL-INJECTION PUMP
Rating:
19
Buy FUEL-INJECTION PUMP 101041-9070 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 131066-6820 PUMP HOUSING
1/22. [1] 139916-0100 CAPSULE
1/30. [3] 029040-6020 STUD
1/35. [1] 131400-0100 ADAPTOR
1/40A. [1] 131002-4700 ADAPTOR
1/50A. [1] 131311-0000 SPACER RING
2. [1] 131028-6220 COVER
2/2. [1] 131011-1900 GASKET
3. [2] 131017-1000 FLAT-HEAD SCREW
5. [2] 029340-6020 GASKET D10&6.5T1.00
16. [4] 131034-1501 CAPSULE
21. [3] 139206-0400 UNION NUT
23. [1] 029633-1010 O-RING
30. [4] 131150-0120 PLUNGER-AND-BARREL ASSY
36. [4] 131110-6020 DELIVERY-VALVE ASSEMBLY
37. [4] 131112-2900 COILED SPRING
40. [4] 131115-1200 GASKET D16&8T0.5
41. [4] 131116-8220 FITTING
42. [4] 131117-3100 FILLER PIECE
45. [2] 131122-0320 PLATE
49. [4] 029632-0070 O-RING &20W2
55. [4] 131200-3520 TAPPET
55/2. [1] 131203-0500 BEARING PIN
55/3. [1] 131204-1100 ROLLER
55/4. [1] 131205-0600 BUSHING
55/5. [1] 131206-0700 SLIDER
56/1. [0] 029311-0020 SHIM D19&10T0.30
56/1. [0] 029311-0030 SHIM D19&10T0.40
56/1. [0] 029311-0040 SHIM D19&10T0.50
56/1. [0] 029311-0050 SHIM D19&10T0.6
56/1. [0] 029311-0060 SHIM D19&10T0.7
56/1. [0] 029311-0070 SHIM D19&10T0.8
56/1. [0] 029311-0080 SHIM D19&10T0.9
56/1. [0] 029311-0090 SHIM D19&10T1
56/1. [0] 029311-0110 SHIM D19&10T1.1
56/1. [0] 029311-0120 SHIM D19&10T1.2
56/1. [0] 029311-0130 SHIM D19&10T1.3
56/1. [0] 029311-0140 SHIM D19&10T1.4
56/1. [0] 029311-0270 SHIM D19&10T0.55
56/1. [0] 029311-0280 SHIM D19&10T0.65
56/1. [0] 029311-0290 SHIM D19&10T0.75
56/1. [0] 029311-0310 SHIM D19&10T0.85
56/1. [0] 029311-0320 SHIM D19&10T0.95
56/1. [0] 029311-0330 SHIM D19&10T1.05
56/1. [0] 029311-0340 SHIM D19&10T1.15
56/1. [0] 029311-0350 SHIM D19&10T1.25
56/1. [0] 029311-0490 SHIM D19&10T1.5
56/1. [0] 029311-0500 SHIM D19&10T1.6
56/1. [0] 029311-0580 SHIM D19&10T0.2
56/1. [0] 029311-0590 SHIM D19&10T0.25
56/1. [0] 029311-0600 SHIM D19&10T0.35
56/1. [0] 029311-0610 SHIM D19&10T0.45
56/1. [0] 029311-0620 SHIM D19&10T1.35
56/1. [0] 029311-0630 SHIM D19&10T1.45
56/1. [0] 029311-0710 SHIM D19&10T1.55
61. [4] 131215-2100 COMPRESSION SPRING
62. [4] 131216-0400 SLOTTED WASHER
63. [4] 131217-0600 SLOTTED WASHER
67. [1] 131254-0000 CONTROL RACK
68. [1] 131226-0300 FLAT-HEAD SCREW
76. [4] 131240-0100 PINION
77. [4] 131241-0500 CONTROL SLEEVE
78. [4] 131242-0100 FLAT-HEAD SCREW
90. [1] 131366-0400 CAMSHAFT
91A. [1] 016640-2030 BEARING PLATE
91B. [1] 028202-0020 BEARING PLATE
91E. [1] 016640-2030 BEARING PLATE
91F. [1] 028202-0020 BEARING PLATE
92. [1] 131302-1000 SPACER RING
92A. [1] 131302-1000 SPACER RING
93/1. [0] 029312-0220 SHIM D27&20T0.1
93/1. [0] 029312-0230 SHIM D27&20T0.12
93/1. [0] 029312-0240 SHIM D27&20T0.14
93/1. [0] 029312-0250 SHIM D27&20T0.16
93/1. [0] 029312-0260 SHIM D27&20T0.18
93/1. [0] 029312-0270 SHIM D27&20T0.5
93/1. [0] 029312-0290 SHIM D27&20T0.3
93/1. [0] 029312-0300 SHIM D27&20T1.0
93/1. [0] 139420-0400 SHIM D27&20T0.7
93A/1. [0] 029312-0220 SHIM D27&20T0.1
93A/1. [0] 029312-0230 SHIM D27&20T0.12
93A/1. [0] 029312-0240 SHIM D27&20T0.14
93A/1. [0] 029312-0250 SHIM D27&20T0.16
93A/1. [0] 029312-0260 SHIM D27&20T0.18
93A/1. [0] 029312-0270 SHIM D27&20T0.5
93A/1. [0] 029312-0290 SHIM D27&20T0.3
93A/1. [0] 029312-0300 SHIM D27&20T1.0
93A/1. [0] 139420-0400 SHIM D27&20T0.7
100. [1] 029622-0190 PACKING RING
101. [1] 131330-7100 COVER
104. [4] 020006-2040 BLEEDER SCREW M6P1L20 4T
106. [1] 131321-1900 GASKET
112. [1] 029470-4030 WOODRUFF KEY
117. [1] 029731-4680 EYE BOLT
131A. [1] 134424-4120 OVER FLOW VALVE
191. [1] 131460-3320 BRACKET
191/2. [4] 029041-0010 STUD
192. [1] 029637-5020 O-RING &73.5W2
194. [4] 014011-0140 PLAIN WASHER D22&10.5T1.6
195. [4] 014111-0440 LOCKING WASHER
196. [4] 131465-0000 UNION NUT
334. [1] 029731-0120 EYE BOLT
336. [2] 026510-1340 GASKET D13.4&10.2T1

Include in #1:

101401-9460 as FUEL INJECTION PUMP

Cross reference number

Zexel num
Bosch num
Firm num
Name
101041-9070 
9 410 610 608 
NP-PES4AD100B321RS2 
   
FUEL-INJECTION PUMP
Q




Information:

Procedure
Note: Prior to performing the analysis with the APC, be sure to read and understand all the interferences listed in the "Interferences Inherent In the Fuel Sample" section of this document. Ensure that all precautions have been taken to minimize the affect of skewed results due to improper sampling, handling, or preparation.
Obtain the fuel sample to be analyzed in an appropriate sample bottle as described in the "Fuel Sample Preparation" section. Manually or mechanically shake the sample vigorously for 30 seconds. When manually shaking a sample, ensure thorough mixing of the sample by turning the bottle so that the lid is facing downward. Shake by moving the wrist and/or forearm up and down as rapidly as is comfortable for the 30 seconds.Note: Degassing samples can be accomplished with either the use of an ultrasonic bath or with the use of a vacuum pump.
Immediately degas the sample, by partially opening the lid to the bottle and placing the sample upright in the degassing unit. Perform only one of the degassing methods. An ultrasonic bath is the best method for degassing a sample. An ultrasonic bath takes the least amount of time minimizing the impact of particle settling.Note: The purpose of partially unscrewing or opening the lid is to promote quick degassing of the sample. Air bubbles to remaining near the surface of the sample following the degassing process are acceptable.
Illustration 5 g01741117
If an ultrasonic bath is unavailable, an alternative method of degassing the sample is with the use of a 1U-5718 Oil Sampling Vacuum Pump. Ensure the 1U-5718 Oil Sampling Vacuum Pump is clean before beginning the degas process.Note: Rubber is to be placed over the hole of the tubing for the pump to develop and hold the required vacuum.
With the sample to be analyzed in the sample bottle, thread the bottle into the bottom of the 1U-5718 Oil Sampling Vacuum Group. Operate the pump to create a vacuum. Maintain the vacuum until all air bubbles have risen to the surface of the sample and dissipated.
If an ultrasonic bath or a vacuum pump is not available, the sample can degas naturally. Degas the sample by setting the sample on a flat surface and leaving the sample undisturbed. If the APC performs a flushing cycle, let the sample sit for 15 seconds. If the APC does not perform a flushing cycle, such as the 293-8413 HYDAC Contamination Monitor Group or the 383-4255 HYDAC Contamination Monitor Group, let the sample sit for 30 seconds. Proceed to the "Sample Processing" section.Sample Processing
Remove the lid from the sample bottle. Immediately begin the processing of the sample on the APC that has been prepared according to the "Fuel Sample Preparation" section.Note: If more than 45 seconds elapse after the shaking of the sample, the procedure shall be restarted with shaking of the sample in "Fuel Sample Preparation" section. Shaking the sample ensures that suspended particles do not settle to the bottom of the sample, causing inaccurate particle count results.
Obtain the particle count results

Have questions with 101041-9070?





Group cross 101041-9070 ZEXEL

9 410 610 299 
 
FUEL-INJECTION PUMP
9 410 610 300 
 
FUEL-INJECTION PUMP
101041-9070  
9 410 610 608 
NP-PES4AD100B321RS2 
 
FUEL-INJECTION PUMP

Mitsubishi 

9 410 610 335 
NP-PES4A95C320RS2S 
ME740095 
FUEL-INJECTION PUMP
Back to top