Illustration 1 g00565418
4W-8471 Time Delay Relay
Use a 6V-7070 Digital Multimeter, a stopwatch, and a battery (8 volts to 40 volts) for this test.
Connect the positive lead of the voltage source to terminal (TD-4) of the time delay relay. Connect the negative lead to terminal (TD-3). If the test is done on an engine, the start/stop switch must be in the STOP position in order to power terminal (TD-6). All connections must be maintained until the tests are completed.
Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 1
Terminals     Relay Position    
5-6     Closed    
6-7     Open    
Connect the positive lead of the voltage source to terminal (TD-1). If the time delay relay is tested on the engine do not leave the voltage source hooked to terminal (TD-1) for more than 60 seconds. The fuel shutoff solenoid will be energized. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 2
Terminals     Relay Position    
5-6     Open    
6-7     Closed    
Remove the positive lead of the voltage source from terminal (TD-1). Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 3
Terminals     Delay Time of Relay Position    
0 to 60 seconds 80 seconds or more    
5-6     Open     Closed    
6-7     Closed     Open    Note: If a jumper is normally installed across terminals (TD-2) and (TD-3), the jumper must be removed before performing Step 5.
Connect the positive lead of the voltage source to terminal (TD-2). If the time delay relay is tested on the engine, do not leave the voltage source on terminal (TD-2) for more than 60 seconds. The fuel shutoff solenoid will be energized. Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 4
Terminals     Delay Time of Relay Position    
0 to 8 seconds 10 seconds or more    
5-6     Closed     Open    
6-7     Open     Closed    
Remove the positive lead of the voltage source from terminal (TD-1). Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 5
Terminals     Delay Time of Relay Position    
0 to 60 seconds 80 seconds or more    
5-6     Open     Closed    
6-7     Closed     Open    
Remove the voltage source from terminal (TD-4). Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 6
Terminals     Relay Position    
5-6     Closed    
6-7     Open    

Have questions with 101040-8150?





Group cross 101040-8150 ZEXEL

Isuzu 

9 410 612 557 
NP-PES4A95C412RS2000NP439 
9812105261 
FUEL-INJECTION PUMP

Yanmar 

9 410 612 558 
NP-PES4A95C420RS2000NP502 
12742051092 
FUEL-INJECTION PUMP

Isuzu 

9 410 612 559 
NP-PES4A95C412RS2000NP575 
5156100520 
FUEL-INJECTION PUMP
101040-8150  
9 410 612 560 
NP-PES4A95C412RS2000NP594 
8943689490 
FUEL-INJECTION PUMP
9 410 612 561 
 
FUEL-INJECTION PUMP

Yanmar 

9 410 612 411 
NP-PES4A95C420RS2000NP659 
12741051090 
FUEL-INJECTION PUMP

Isuzu 

9 410 611 328 
NP-PES4A95C410RS2000NP670 
5156011040 
FUEL-INJECTION PUMP
9 410 610 701 
NP-PES4A95C410RS2000NP671 
5156101030 
FUEL-INJECTION PUMP
Back to top