156423-1920 ZEXEL 9 423 610 668 BOSCH FLANGE BUSHING 9423610668 1564231920 me742415


 

Information flange bushing

BOSCH 9 423 610 668 9423610668
ZEXEL 156423-1920 1564231920
MITSUBISHI ME742415 me742415
156423-1920 FLANGE BUSHING
Rating:
44
Buy FLANGE BUSHING 156423-1920 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Number on scheme 3
FLANGE BUSHING
1056431150 as FLANGE BUSHING

Cross reference number

Zexel num
Bosch num
Firm num
Name
156423-1920 
9 423 610 668 
ME742415  MITSUBISHI
FLANGE BUSHING
C 14GQ FLANGE TIMER




Information:

Storage Procedure
When a generator is in storage for any length of time, moisture condenses in the windings. Minimize the condensation by use of a dry storage space and space heaters. Refer to step 2 belowIf a brush-type generator (SRCR) is to be in storage for a year or more, lift the brushes off the slip ring to prevent damage to the slip ring by chemical action.After Storage
Test the main stator windings with a megohmmeter in the following situations: 1. Before initial startup of generator set.2. Every 3 months* if generator is operating in a humid environment.3. If generator has not been run under load for 3 months* or more.*This is a guideline only. It may be necessary to megger more frequently if environment is extremely humid, salty or if the last megger test was close to 1 megohm.The megohmmeter test is described in Service Manuals SENR2180 or SENR7968. A reading of 1 meghom or less indicates that the winding has absorbed too much moisture.To Remove Moisture
To remove moisture caused by high humidity, use one of the following methods to make the generator dry:1. Energize space heaters in generator if so equipped.2. Put the generator in an oven at a temperature of not more than 85°C (185°F) for four hours.
If an oven is used for drying, use a forced air type rather than a radiant type. Radiant ovens can cause localized overheating.
3. Space heaters of the same type used in marine applications, can be installed on generators. (See the Parts Book.) These heaters heat the windings to remove moisture and should be connected at all times in high humidity conditions whenever the generator is not running.4. Use a canvas enclosure around the generator and heating lamps to increase the temperature. Make an opening in the top for release of moisture.5. Send a low voltage current through the windings to increase the temperature of the windings. Do not exceed 85°C (185°F).If the megohmmeter test reads under 1 megohm after the drying or if it goes below 1 megohm shortly after drying, contact your Caterpillar dealer. The insulation has deteriorated and should be reconditioned.

Have questions with 156423-1920?





Group cross 156423-1920 ZEXEL

Mitsubishi 

156423-1920  
9 423 610 668 
ME742415 
FLANGE BUSHING
Back to top