146125-0100 ZEXEL 9 461 611 412 BOSCH FILTER 9461611412 1461250100


 

Information filter

BOSCH 9 461 611 412 9461611412
ZEXEL 146125-0100 1461250100
146125-0100 FILTER
Rating:
70
Buy FILTER 146125-0100 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Number on scheme 251
FILTER   
NMC LD28 GY1
1047482460 as FILTER NMC LD28 GY1

Cross reference number

Zexel num
Bosch num
Firm num
Name
146125-0100 
146125-0101 
9 461 611 412 
   
FILTER
*




Information:

password protection for the CCM is initially enabled. Password protection may be necessary for some applications. Use the following procedure to enable password protection. Changing the password protection can be done with the PC software for the CCM . The password protection can also be changed by using a host device to write the IIDs.Disabling PasswordsTo disable the passwords, the AA12 and AA8A PIDs must be used.Note: Refer to the Operation and Maintenance Manual, "Parameter Identifiers for General Usage".
Use IID 34 with a unit number of 61. Write to PID AA8A with the level 3 password. This will set the security level in the CCM to level 3. The message will be 5000340C0061AA8Ab1b2b3b4b5b6b7b8cs. The example above shows that b1 through b8 are the ASCII characters of the password. If the password is all spaces, simply end the message after PID AA8A. Do not include any of the data bytes. The CCM will automatically add spaces when a character is not present.
Use IID 34 with a unit number of 61. Write PID AA 12 with bit 3 set. This will disable the password protection. The message will be 500034050061AA1204cs. This message will disable the passwords. Baud rate changes will be enabled. The CCM will be set for a direct connection. Bits 1 and 2 should be set to 1 if the last two items need to be set the other way. Note: When the passwords are disabled, all three passwords are set to all blanks (spaces).Enabling PasswordsThe AA12 and the F012 PIDs must be used in order to enable the password protection.Note: Refer to the Operation and Maintenance Manual, "Parameter Identifiers for General Usage".
Use IID 34 with a unit number of 61. Write to PID AA12 to clear bit 3. The message format will be 500034050061AA1200cs. This message will enable the following items: passwords, change of baud rate and set the CCM for direct connect. Bits 1 and 2 should be set to 1 if the last two items need to be set the other way.
In order to enable the changes, the power to the CCM must be cycled or the security level must be written to zero. The security level is written to zero by using IID 34. The message will be 500034050061F01200cs. Note: When the passwords were disabled, each character was set to a blank or space. Set the level 3 password on the CCM to something other than spaces.

Have questions with 146125-0100?





Group cross 146125-0100 ZEXEL

146125-0100  

146125-0101 
9 461 611 412 
 
FILTER

Isuzu 

9 461 613 603 
8973285580 
FILTER
9 461 613 603 
8973227700 
FILTER

Mitsubishi 

9 461 613 603 
ME742567 
FILTER

Nissan 

9 461 613 603 
16728V7200 
FILTER
9 461 613 603 
16728G8110 
FILTER
9 461 613 603 
16728G8001 
FILTER
9 461 613 603 
1672844G00 
FILTER

Nissan-Diesel 

9 461 613 603 
1672844G00 
FILTER

Mazda 

9 461 613 603 
WL0113VF5 
FILTER
Back to top