105932-0190 ZEXEL Cross 1059320190


 

Information

ZEXEL 105932-0190 1059320190
105932-0190 None
Rating:
18
Buy None 105932-0190 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105932-0190 
 
   





Information:

Test Procedure
System Operation
The SLC 5/04 diagnostic indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: Input devices, Output devices, Wiring and The controller.The green "RUN" LED is illuminated. The processor is in the "RUN" mode.The red "FLT" LED is flashing during operation. The processor detects a major fault. The fault is in the processor expansion chassis or the fault is in the memory.The amber "FORCE" LED is illuminated. The forces are enabled.The amber "FORCE" LED is not illuminated. No forces are present or no forces are enabled.
Illustration 1 g00563544
Diagram of the LED indicators
Illustration 2 g00562937
Functional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 2.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Clear the fault.
Place the switch in the PROG position.
Place the switch in the RUN position.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Proceed to 3.
Cycle the power.
Secure power to the PLC.
Energize the PLC.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Refer to Maintenance Procedure, "Processor - Replace".

Have questions with 105932-0190?





Group cross 105932-0190 ZEXEL

Mitsubishi 

 
ME731990 
GOVERNOR
F 019 Z5E 822 
NP-EP/RLD275-1550A1CFL 
ME738710 
GOVERNOR
 
ME731991 
GOVERNOR
 
ME738537 
GOVERNOR
 
ME738783 
GOVERNOR
9 420 610 485 
ME740026 
GOVERNOR
9 420 610 486 
NP-EP/RLD275-1550A1FFL 
ME742205 
GOVERNOR
9 420 613 865 
ME731992 
GOVERNOR
 
ME738538 
GOVERNOR
 
ME738591 
GOVERNOR
9 420 611 633 
ME740023 
GOVERNOR
 
ME740080 
GOVERNOR
9 420 611 057 
ME740653 
GOVERNOR
9 420 611 058 
NP-EP/RLD275-1550A1FFL 
ME741760 
GOVERNOR
 
ME738427 
GOVERNOR
9 420 613 649 
NP-EP/RLD275-1550A1FFL 
 
GOVERNOR

Isuzu 

9 420 613 942 
8971097360 
GOVERNOR
9 420 613 942 
8971096650 
GOVERNOR
F 019 Z1E 248 
8971096651 
GOVERNOR
F 01G 29N 064 
NP-EP/RLD275-1500A2FXL 
 
GOVERNOR

Isuzu 

9 420 613 943 
8971097340 
GOVERNOR
9 420 611 316 
NP-EP/RLD300-1950A2FFL 
8971097341 
GOVERNOR
9 420 612 702 
8971097350 
GOVERNOR
9 420 611 317 
NP-EP/RLD300-1950A2FBL 
8971097351 
GOVERNOR

Mitsubishi 

9 420 613 650 
NP-EP/RLD275-1550A1EFL 
ME738449 
GOVERNOR
9 420 613 097 
 
GOVERNOR
 
 
GOVERNOR
105932-0190  
 
 

 
 

Back to top