Information:


To avoid possible engine damage or another immediate shutdown, the water temperature fault must be corrected before attempting to restart the engine.
Even though the starter motor circuit can now be engaged, there is no fuel flow to the engine. The fuel flow to the engine is stopped until the coolant temperature falls below the rating for the water temperature contactor switch (WTS). When the coolant temperature falls below the rating for the water temperature contactor switch (WTS), the contactor switch opens again. The fuel shutoff solenoid is de-energized when the switch reopens. This allows fuel flow to the engine. The engine can then be restarted.2301A Electric Governor Control
The 2301A Electric Governor Control activates all of the components that are in the electric protection system. The components are activated in the same manner when the nonelectric governor is used. One difference exists in the main circuit. The fuel shutoff solenoid (FSOS) (line 43) is not used.When the electric governor control is used, the engine must run in a normal condition in order for the electric circuit to operate in the manner that is described below.
Current flows from the terminals (TS-28) (line 43) and (TS-31) (line 44), which are located on the terminal strip in the junction box.
Current from terminals (TS-28) (line 43) and (TS-31) (line 44) flows through the preregulator (PR) (line 48) or the fuse (F4) to the electric governor control.
When the engine flywheel is rotating, the current also flows through the electric governor actuator (EGA) (line 52). When a fault in the system causes the current to energize the slave relay (SR1), the following events occur in the electric circuit in order to stop the engine.
The slave relay (SR1) opens across the contacts (SR1-30) and (SR1-87a) (line 45). The relay closes across the contacts (SR1-30) and (SR1-87) (line 43).
When the circuit opens across contacts (SR1-30) and (SR1-87a), the current is stopped to the electric governor control.
Current to the electric governor actuator (EGA) is also stopped.
The mechanical spring load in the electric governor actuator (EGA) will now move the fuel control rod in order to stop fuel flow to the engine.Note: With the exception of the differences that are described in this section of the manual, all of the fault circuits in the electric protection system are identical for the 2301A Electric Governor Control and for the nonelectric governor control.
Illustration 3 g00292518
Junction Box Wiring for ETS with OP, WT,

Have questions with 105921-3121?





Group cross 105921-3121 ZEXEL

F 019 Z2F 010 
NP-EP/RLD350-1650A1EFR 
 
GOVERNOR

Nissan-Diesel 

F 019 Z2F 011 
19101Z5761 
GOVERNOR
105921-3121  
 
 

Nissan-Diesel 

F 019 Z5E 338 
NP-EP/RLD275-1600A1EXR 
19101Z5766 
GOVERNOR
9 420 614 067 
NP-EP/RLD325-1750A1FXR 
 
GOVERNOR

Hino 

9 420 614 067 
NP-EP/RLD325-1750A1FXR 
223005150A 
GOVERNOR

Nissan-Diesel 

F 019 Z5E 339 
NP-EP/RLD275-1500A1AXR 
19101Z5767 
GOVERNOR

Mitsubishi 

 
ME726366 
GOVERNOR
F 019 Z5E 340 
NP-EP/RLD325-1750A2EXR 
ME726976 
GOVERNOR

Hino 

F 019 Z1E 352 
NP-EP/RLD250-1500A4EFR 
223005220A 
GOVERNOR
F 019 Z1E 352 
NP-EP/RLD250-1500A4EFR 
223006690A 
GOVERNOR

Isuzu 

9 420 613 017 
NP-EP/RLD250-1400A1BFR 
1157701900 
GOVERNOR

Hino 

F 019 Z1E 353 
NP-EP/RLD300-1750A1AXR 
223005300A 
GOVERNOR

Mitsubishi 

F 019 Z1E 353 
NP-EP/RLD300-1750A1AXR 
ME727056 
GOVERNOR
Back to top