105636-1190 ZEXEL Cross 1056361190


 

Information

ZEXEL 105636-1190 1056361190
105636-1190 None
Rating:
13
Buy None 105636-1190 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105636-1190 
 
   





Information:


Table 1
Diagnostic Trouble Codes
J1939 Code and Description CDL Code and Description
4334–20
Aftertreatment #1 DEF #1 Pressure (absolute) : Data Drifted High 3090–20
Aftertreatment #1 DEF Pressure Sensor : Data Drifted High
4334-21
Aftertreatment #1 DEF #1 Pressure (absolute) : Data Drifted Low 3090-21
Aftertreatment #1 DEF Pressure Sensor : Data Drifted Low
3361-5
Aftertreatment #1 DEF Dosing Unit : Current Below Normal 3821-5
Aftertreatment #1 Diesel Exhaust Fluid Dosing Valve Actuator : Current Below Normal
3361-6
Aftertreatment #1 DEF Dosing Unit : Current Above Normal 3821-6
Aftertreatment #1 Diesel Exhaust Fluid Dosing Valve Actuator : Current Above Normal
3516-12
Aftertreatment #1 DEF Concentration : Failure 3100-12
Aftertreatment #1 DEF Tank Fluid Quality Sensor : Failure
Table 2
Event Codes
J1939 Code and Description CDL Code and Description
5392-31
Aftertreatment Diesel Exhaust Fluid Dosing Unit Loss of Prime E1370 (2)
Aftertreatment #1 DEF Dosing Unit Loss of Prime
4334-18
Aftertreatment #1 DEF #1 Pressure (absolute) : Low - moderate severity (2) E931 (2)
Low Aftertreatment #1 DEF Pressure
4334-16
Aftertreatment #1 DEF #1 Pressure (absolute) : High - moderate severity (2) E930 (2)
High Aftertreatment #1 DEF Pressure
3516-16
Aftertreatment #1 DEF Concentration : High - moderate severity (2) E1365 (2)
High Aftertreatment #1 DEF Concentration
3516-18
Aftertreatment #1 DEF Concentration : Low - moderate severity (2) E1364 (2)
Low Aftertreatment #1 DEF Concentration
5246-15
Aftertreatment SCR Operator Inducement Severity : High - least severe (1) E1389 (1)
Aftertreatment #1 SCR Operator Inducement
5246-16
Aftertreatment SCR Operator Inducement Severity : High - moderate severity (2) E1389 (2)
Aftertreatment #1 SCR Operator Inducement
5246-0
Aftertreatment SCR Operator Inducement Severity : High - most severe (3) E1389 (3)
Aftertreatment #1 SCR Operator Inducement Ensure that DEF fluid conforms to specification ISO 22241 requirements and fluid handling, filling, and storage procedures are strictly followed.All transfer equipment and storage containers should be used exclusively for DEF and should not be reused for other fluids. For example coolants, fuels, oils, and windshield washer fluid.If contamination of the DEF system is suspected, refer to Troubleshooting, DEF Concentration is Incorrect. Ensure that the correct troubleshooting steps are followed. To test for contamination of the DEF tank, refer to Systems Operation Testing and Adjusting, Diesel Exhaust Fluid Quality - Test.If the DEF is contaminated, Caterpillar recommends that the DEF tank is flushed. Refer to Systems Operation Testing and Adjusting, Diesel Exhaust Fluid Tank - Flush for the correct procedure.

Have questions with 105636-1190?





Group cross 105636-1190 ZEXEL

 
 

9 420 617 098 
NP-EP/SP600-1250Z4RN 
 
AUTOM. ADVANCE MECHANISM

Mitsubishi 

9 420 616 415 
NP-EP/SP930-1050Z2R 
ME717155 
AUTOM. ADVANCE MECHANISM

Nissan-Diesel 

 
16851Z0001 
AUTOM. ADVANCE MECHANISM

Mitsubishi 

 
ME717132 
AUTOM. ADVANCE MECHANISM
9 420 615 037 
NP-EP/SP600-1100Z3R 
ME059662 
AUTOM. ADVANCE MECHANISM

Hino 

9 420 615 026 
NP-EP/SP925-1150Z2.5R 
225001760B 
AUTOM. ADVANCE MECHANISM
9 420 615 026 
NP-EP/SP925-1150Z2.5R 
S225001760B 
AUTOM. ADVANCE MECHANISM

Isuzu 

9 420 616 416 
NP-EP/SP1000-1250Z3L 
1157401870 
AUTOM. ADVANCE MECHANISM
105636-1190  
 
 