105410-7690 ZEXEL Cross 1054107690


 

Information

ZEXEL 105410-7690 1054107690
105410-7690 None
Rating:
52
Buy None 105410-7690 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105410-7690 
 
   





Information:


To avoid possible engine damage or another immediate shutdown, the water temperature fault must be corrected before attempting to restart the engine.
Even though the starter motor circuit can now be engaged, there is no fuel flow to the engine. The fuel flow to the engine is stopped until the coolant temperature falls below the rating for the water temperature contactor switch (WTS). When the coolant temperature falls below the rating for the water temperature contactor switch (WTS), the contactor switch opens again. The fuel shutoff solenoid is de-energized when the switch reopens. This allows fuel flow to the engine. The engine can then be restarted.2301A Electric Governor Control
The 2301A Electric Governor Control activates all of the components that are in the electric protection system. The components are activated in the same manner when the nonelectric governor is used. One difference exists in the main circuit. The fuel shutoff solenoid (FSOS) (line 43) is not used.When the electric governor control is used, the engine must run in a normal condition in order for the electric circuit to operate in the manner that is described below.
Current flows from the terminals (TS-28) (line 43) and (TS-31) (line 44), which are located on the terminal strip in the junction box.
Current from terminals (TS-28) (line 43) and (TS-31) (line 44) flows through the preregulator (PR) (line 48) or the fuse (F4) to the electric governor control.
When the engine flywheel is rotating, the current also flows through the electric governor actuator (EGA) (line 52). When a fault in the system causes the current to energize the slave relay (SR1), the following events occur in the electric circuit in order to stop the engine.
The slave relay (SR1) opens across the contacts (SR1-30) and (SR1-87a) (line 45). The relay closes across the contacts (SR1-30) and (SR1-87) (line 43).
When the circuit opens across contacts (SR1-30) and (SR1-87a), the current is stopped to the electric governor control.
Current to the electric governor actuator (EGA) is also stopped.
The mechanical spring load in the electric governor actuator (EGA) will now move the fuel control rod in order to stop fuel flow to the engine.Note: With the exception of the differences that are described in this section of the manual, all of the fault circuits in the electric protection system are identical for the 2301A Electric Governor Control and for the nonelectric governor control.
Illustration 5 g00292456
Junction Box Wiring for ETS with OP, WT, and OS that does not require a switchgear for use on 3200 through 3400 Engines
Illustration 6 g00292457
JIC Schematic for ETS with OP, WT, and OS that does not require a switchgear for use on 3200 through 3400 Engines
Illustration 7 g00292458
IEC Schematic for ETS with OP, WT, and OS that does not require a switchgear for use on 3200 through 3400 Engines
Illustration 8 g00292474
6I-1862 Wiring Harness for ETS with OP, WT, and OS that does not require a switchgear for use on 3200 through 3400 Engines
Illustration 9 g00292459
Junction Box Wiring for ETS with OP, WT, and OS that does not require a switchgear for

Have questions with 105410-7690?





Group cross 105410-7690 ZEXEL

 
 
GOVERNOR

Isuzu 

F 019 Z1E 098 
NP-EP/RSV200-1450AQ43A301 
1157207300 
GOVERNOR
F 019 Z1E 099 
 
GOVERNOR
 
 

9 420 610 195 
NP-EP/RSV200-1300AQ39A21 
 
GOVERNOR
9 420 610 196 
NP-EP/RSV200-1200AQ36A21 
 
GOVERNOR

Isuzu 

F 019 Z1E 100 
NP-EP/RSV200-1300AQ44A311 
8943663260 
GOVERNOR
F 019 Z1E 100 
NP-EP/RSV200-1300AQ44A311 
8943359010 
GOVERNOR
F 019 Z1E 101 
 
GOVERNOR
F 019 Z2F 525 
 
GOVERNOR
 
 

105410-7690  
 
 