105400-1800 ZEXEL Cross 1054001800


 

Information

ZEXEL 105400-1800 1054001800
105400-1800 None
Rating:
65
Buy None 105400-1800 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105400-1800 
 
   





Information:

Battery
Never disconnect any charging unit circuit or battery circuit cable from battery when the charging unit is operated. A spark can cause an explosion from the flammable vapor mixture of hydrogen and oxygen that is released from the electrolyte through the battery outlets. Injury to personnel can be the result.
The battery circuit is an electrical load on the charging unit. The load is variable because of the condition of the charge in the battery. Damage to the charging unit can result if the connections (either positive or negative) between the battery and charging unit are broken while the charging unit is in operation. This is because the battery load is lost and there is an increase in charging voltage. High voltage can damage, not only the charging unit, but also the regulator and other electrical components.Use the 6V4930 Battery Load Tester, the 8T900 Clamp-On Ammeter and the 6V7070 Multimeter to load test a battery that does not hold a charge when in use. See Special Instruction Form No. SEHS8268 for the correct procedure and specifications to use.Charging System
The condition of charge in the battery at each regular inspection will show if the charging system operates correctly. An adjustment is necessary when the battery is constantly in a low condition of charge or a large amount of water is needed (more than one ounce of water per cell per week or per every 100 service hours).When it is possible, make a test of the charging unit and voltage regulator on the engine, and use wiring and components that are a permanent part of the system. Off-engine (bench) testing will give a test of the charging unit and voltage regulator operation. This testing will give an indication of needed repair. After repairs are made, again make a test to give proof that the units are repaired to their original condition of operation.Before the start of on-engine testing, the charging system and battery must be checked as shown in the Steps that follow:1. Battery must be at least 75% (1.225 Sp.Gr.) fully charged and held tightly in place. The Battery holder must not put too much stress on the battery.2. Cables between the battery, starter and engine ground must be the correct size. Wires and cables must be free of corrosion and have cable support clamps to prevent stress on battery connections (terminals).3. Leads, junctions, switches, and panel instruments that have direct relation to the charging circuit must give correct circuit control.4. Inspect the drive components for the charging unit to be sure they are free of grease and oil and have the ability to operate the charging unit.Alternator Regulator Adjustment (Delco-Remy)
When an alternator is charging the battery too much or not enough, the charging rate of the alternator should be checked. Make reference to the SPECIFICATIONS section to find all testing specifications for the alternators and regulators.
3T7070 & 9L5938 Alternator
(1) Pulley nut. (2) Ground terminal.No adjustment can be made to change the rate of charge on the alternator regulators. If

Have questions with 105400-1800?





Group cross 105400-1800 ZEXEL

105400-1800  
 
 

Yanmar 

9 420 612 728 
NP-EP/RSV200-1450AQ43A312NP42D 
12761061551 
GOVERNOR

Nissan-Diesel 

 
19200Z5565 
GOVERNOR

Hino 

 
223001660A 
GOVERNOR

Yanmar 

9 420 614 948 
NP-EP/RSV200-1450AQ43A312NP45D 
12741061551 
GOVERNOR
F 019 Z4E 009 
 
GOVERNOR

Hino 

F 019 Z2F 529 
223001700A 
GOVERNOR
 
223001710A 
GOVERNOR
F 019 Z1E 257 
NP-EP/RSV200-1100A7A302NP194D 
223001720A 
GOVERNOR

Nissan-Diesel 

F 019 Z4E 147 
NP-EP/RSV200-1300A1A302NP196 
19200Z5566 
GOVERNOR
Back to top