105220-6010 ZEXEL Cross 1052206010


 

Information

ZEXEL 105220-6010 1052206010
105220-6010 None
Rating:
58
Buy None 105220-6010 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105220-6010 
 
   





Information:

1. Remove the pickup from the injection line. Check to be sure the pickup and injection line are clean and dry. The inner bore of the pickup that contacts the injection line must be clean and dry. If necessary, clean the inner bore with a soft dry cloth. If the pickup is damp, dry it in an oven at approximately 50°C (122°F) before reinstalling on the fuel injection line.2. Check the fuel injection line on which the pickup was installed. Make sure all paint has been removed from around the line and that clean bare metal is exposed. Use fine emery paper to clean the line if necessary.3. Reinstall the pickup on the fuel injection line. Make sure the thumbscrew is tight and the pickup is not touching anything except the line. Observe the NO INPUT SIGNAL light and the digital readout on the multitach. If the light stays on bright all the time and the digital display reads 0 when the engine is running, the pickup is not operating. Remove the pickup and amplifier, and test the pickup and amplifier as shown on pages 6 and 7, or use a different pickup and amplifier.4. If the pickup is operating but the NO INPUT SIGNAL light and digital readout are erratic, the pickup output signal is either too low or it is noisy. Run the engine at low and high speeds. If the output signal is too low, the pickup will operate better at high engine speeds. If the signal is noisy, the pickup will usually perform better at low engine speeds. To correct either of these problems, loosen the thumbscrew and rotate the pickup to a new position on the line. Tighten the thumbscrew. Check to see if this solves the problem. To correct noisy operation, it may also be necessary to remove the pickup and reverse it 180° so the signal line points in the opposite direction.5. If pickup operation is still erratic after performing the previous steps, move the pickup to a new location on the same line or to a different line. Make sure each new location is properly prepared before installing pickup. To correct noisy operation (erratic signal and high speed readings), try a pickup location as close as possible to a point where the injection line is fastened to the engine.(D) Use Of The Pickup During Wet Conditions
If the pickup becomes wet, it may operate intermittently or not at all. Although the pickup is water resistant, it is not waterproof. Water spray from rain or other sources may cause the pickup to stop producing an output signal. If this happens, the pickup should be removed from the engine and allowed to dry out thoroughly. If necessary, the pickup can be dried in an oven at approximately 50°C (122°F). After drying, the pickup should operate correctly. If it is not possible to keep the pickup dry, use the following procedure. If the pickup must be used during wet conditions, it may be possible

Have questions with 105220-6010?





Group cross 105220-6010 ZEXEL

Isuzu 

9 440 610 443 
8970321850 
SUPPLY PUMP
105220-6010  
 
 

Nissan 

9 440 610 204 
NP-FP/KS-A 
166400T000 
SUPPLY PUMP

Nissan-Diesel 

9 440 610 204 
NP-FP/KS-A 
166400T000 
SUPPLY PUMP
9 440 610 958 
NP-FP/KS-AD 
 
SUPPLY PUMP
 
 

Mitsubishi 

9 440 610 393 
NP-FP/KS-AD 
ME730338 
SUPPLY PUMP

Hino 

9 440 610 379 
NP-FP/KS-A 
225602070A 
SUPPLY PUMP
9 440 610 379 
NP-FP/KS-A 
S225602070 
SUPPLY PUMP
9 440 610 379 
NP-FP/KS-A 
S225602070A 
SUPPLY PUMP
 
 

Isuzu 

9 440 610 444 
8970631560 
SUPPLY PUMP
Back to top