Information electric governor
BOSCH
F 019 Z2E 768
f019z2e768
ZEXEL
105962-0170
1059620170
ISUZU
1157901270
1157901270

Rating:
Scheme ###:
1. | [1] | 159560-2600 | GOVERNOR HOUSING |
2. | [8] | 139006-4100 | BLEEDER SCREW |
4. | [1] | 159635-8500 | COILED SPRING |
5. | [1] | 159564-4000 | SLOTTED WASHER |
6. | [1] | 159636-5800 | SLOTTED WASHER |
7. | [1] | 159636-3221 | CONNECTOR |
7B. | [1] | 159636-3421 | CONNECTOR |
7C. | [1] | 159636-3621 | CONNECTOR |
8. | [1] | 020105-1240 | BLEEDER SCREW M5P0.8L12 |
11. | [1] | 159620-6720 | ACTUATOR |
11/2. | [1] | 159583-1020 | STRAP |
11/3. | [1] | 159563-1700 | LEVER SHAFT |
11/4. | [2] | 029311-0170 | SHIM |
11/4. | [2] | 029311-0170 | SHIM |
11/5. | [2] | 159635-0200 | O-RING |
11/5. | [2] | 159635-0200 | O-RING |
11/6. | [2] | 014011-0140 | PLAIN WASHER D22&10.5T1.6 |
11/6. | [2] | 014011-0140 | PLAIN WASHER D22&10.5T1.6 |
11/8. | [1] | 016010-0940 | LOCKING WASHER |
11/10. | [4] | 139006-9100 | BLEEDER SCREW |
11/11. | [1] | 407914-1880 | CONTROL UNIT |
11/12. | [4] | 010235-1640 | HEX-SOCKET-HEAD CAP SCREW |
11/14. | [4] | 029300-5020 | PLAIN WASHER D10&5.1T1.5 |
11/15. | [1] | 159636-0500 | LIP |
11/17. | [1] | 159630-5020 | CABLE SET |
11/18. | [2] | 020105-1640 | BLEEDER SCREW M5P0.8L16 |
11/21. | [1] | 159583-6020 | CONTROL LEVER |
11/22. | [1] | 159563-2000 | COILED SPRING |
11/23. | [1] | 159563-1800 | BUSHING |
11/24. | [1] | 014110-8440 | LOCKING WASHER |
11/25. | [1] | 013030-8140 | UNION NUT M8P1.25H5 |
11/26. | [1] | 159563-1000 | FLAT-HEAD SCREW |
11/27. | [1] | 155615-1700 | FLAT-HEAD SCREW |
11/28. | [2] | 029240-6010 | UNION NUT M6P1.0H5* |
11/28. | [2] | 029240-6010 | UNION NUT M6P1.0H5* |
11/32. | [2] | 020106-1440 | BLEEDER SCREW M6P1.0L14 |
11/34. | [1] | 155615-1100 | FLAT-HEAD SCREW M6P1.0L37 |
11/39. | [2] | 159635-5200 | SEAL RING |
11/40. | [4] | 020106-2840 | BLEEDER SCREW |
12. | [2] | 020106-4040 | BLEEDER SCREW |
13. | [1] | 159561-1520 | GOVERNOR COVER |
14. | [6] | 139006-1300 | BLEEDER SCREW M6P1L76 |
15. | [2] | 029010-6550 | BLEEDER SCREW |
16. | [8] | 014110-6440 | LOCKING WASHER |
16. | [8] | 014110-6440 | LOCKING WASHER |
17. | [1] | 159584-7600 | GASKET |
18. | [1] | 159635-0100 | GASKET |
19. | [1] | 154390-0500 | GASKET |
20. | [1] | 153021-5000 | CAP |
21. | [1] | 026524-3040 | GASKET |
22. | [1] | 159564-0800 | EYE BOLT |
23. | [2] | 139514-0000 | GASKET D19.2&14.2T1.0 |
65. | [2] | 159635-0400 | BUSHING |
80. | [1] | 159586-6600 | TOOTHED GEAR |
81. | [1] | 014111-2420 | LOCKING WASHER |
82. | [1] | 013031-2120 | UNION NUT |
83. | [1] | 025803-1310 | WOODRUFF KEY |
804S. | [1] | 159911-2300 | PLUG HOUSING |
805S. | [1] | 159911-2400 | PLUG HOUSING |
806S. | [1] | 159911-2500 | PLUG HOUSING |
Include in #1:
107692-1610
as GOVERNOR
Cross reference number
Zexel num
Bosch num
Firm num
Name
Information:
Do not use the same vacuum sampling pump for extracting oil samples that is used for extracting coolant samples.A small residue of either type sample may remain in the pump and may cause a false positive analysis for the sample being taken.Always use a separate pump for oil sampling and a separate pump for coolant sampling.Failure to do so may cause a false analysis which could lead to customer and dealer concerns.
New Systems, Refilled Systems, and Converted Systems
Perform an S O S coolant analysis (Level 2) at the following maintenance intervals.
Initial 500 service hours
Every Year or every 2000 hours, whichever comes firstPerform this analysis at the interval that occurs first for new systems, for refilled systems, or for converted systems that use Cat ELC (Extended Life Coolant) or use Cat DEAC (Diesel Engine Antifreeze/Coolant). This 500 hour check will also check for any residual cleaner that may have contaminated the system.Recommended Interval for S O S Services Coolant Sample
The following table contains the recommended sampling interval for all coolants that meet Cat EC-1 (Engine Coolant specification - 1). This is also the recommended sampling interval for all conventional heavy-duty coolant/antifreeze.The Level 2 Coolant Analysis should be performed if a problem is suspected or identified.
Table 1
Recommended Interval
Type of Coolant Level 1 Level 2
Cat DEAC
and Conventional Heavy-Duty Coolants Every 250 hours Yearly
Cat ELC
and Commercial EC-1 coolants Optional or every 500 hours Yearly or every 500 hours Note: Check the SCA (Supplemental Coolant Additive) of the conventional coolant at every oil change or at every 250 hours. Perform this check at the interval that occurs first.Refer to your machine OMM for recommendations specific to your machine.S O S Services Coolant Analysis (Level 1)
A coolant analysis (Level 1) is a test of the properties of the coolant.The following properties of the coolant are tested:
Glycol concentration for freeze protection and boil protection
Ability to protect from erosion and corrosion
pH
Conductivity
Visual analysis
Odor analysisThe results are reported, and appropriate recommendations are made.S O S Services Coolant Analysis (Level 2)
A coolant analysis ( Level 2) is a comprehensive chemical evaluation of the coolant. This analysis is also a check of the overall condition of the cooling system.The S O S coolant analysis ( Level 2) has the following features:
Full coolant analysis (Level 1)
Identification of metal corrosion and of contaminants
Identification of buildup of the impurities that cause corrosion
Identification of buildup of the impurities that cause scaling
Determination of the possibility of electrolysis within the cooling system of the engineThe results are reported, and appropriate recommendations are made.For more information on S O S coolant analysis, consult your Caterpillar dealer.