105962-0050 ZEXEL ELECTRIC GOVERNOR Cross 1059620050 me748572


 

Information electric governor

ZEXEL 105962-0050 1059620050
MITSUBISHI ME748572 me748572
105962-0050 ELECTRIC GOVERNOR
Rating:
45
Buy ELECTRIC GOVERNOR 105962-0050 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105962-0050 
105962-0051 
 
ME748572  MITSUBISHI
ELECTRIC GOVERNOR
* K




Information:


Repeat Steps 4 through 6 to remove (bleed) air from the rear table lift cylinder (not shown).
Open (CCW) hand pump control knob (11) to completely lower the DPF cleaner table. Close (CW) the hand pump control knob.
Illustration 38 g02728258
(28) Hydraulic Oil Level 51 to 102 mm (2.0 to 4.0 inch)
Check the oil level in the pump reservoir. Remove fill cap (13) located on the end cap of the hand pump. Hydraulic oil level (28) should be 51 to 102 mm (2.0 to 4.0 inch) from the bottom of the fill hole. Add high-grade hydraulic oil, if needed.Note: A clean wire tie can be used as a dipstick to measure the hydraulic oil level in the pump reservoir.Troubleshooting Guide
Table 3
Symptom     Solution    
Air dryer desiccant is a pinkish color.     1. Replace or regenerate the desiccant. Refer to ""Maintenance Section"".    
Bursting does not occur.     1. Check display screen for error message.
2. Check power connection to burst valve solenoid.    
Cabinet doors do not close correctly.     1. Look for damaged door hinges, seals, and latches.
2. Verify that vehicle sensors have been removed from DPF.    
Cabinet doors open during burst process.     1. Verify that doors are correctly latched.
2. Look for damage to door latches.
3. Check seals between DPF and adapters.    
Clamping force cannot be obtained.     1. Look for hydraulic fluid leaks.
2. Check fluid level in hydraulic pump. Refer to ""Maintenance Section"".    
Clamping force does not hold.     1. Upon initial clamping, it is possible for clamp load to drop
689 to 1379 kPa (99.9 to 200.0 psi) within the first minute, due to temperature effects. After reclamping, the drop should be virtually zero.
2. Look for hydraulic fluid leaks.    
Display screen is blank.     1. Verify that machine is ON, plugged into an outlet, and power is available to the outlet.
2. Reset circuit breakers located on left side of control cabinet.    
DPF does not line up correctly on the table.     1. Verify that correct adapters are being used.
2. Verify DPF is correctly seated on to lower adapter.    
DPF is damaged after cleaning process.     1. Check DPFs for damage before cleaning.
2. Look for damage on adapters.
3. Verify that correct cleaning protocol was entered into machine.    
DPF is not cleaned.     1. Check orientation of DPF. Refer to ""General Information"" Section.
2. Verify that correct cleaning protocol was entered into machine.
3. Look for other DPF conditions that may prevent successful cleaning.  

Have questions with 105962-0050?





Group cross 105962-0050 ZEXEL

Mitsubishi 

9 420 613 873 
ME748100 
ELECTRIC GOVERNOR
F 019 Z6E 026 
ME755493 
ELECTRIC GOVERNOR

Nissan-Diesel 

F 019 Z6E 026 
ME748165 
ELECTRIC GOVERNOR

Hino 

9 420 614 554 
223009970A 
ELECTRIC GOVERNOR
9 420 614 645 
224002230A 
ELECTRIC GOVERNOR
9 420 614 804 
224002240A 
ELECTRIC GOVERNOR
 
 
ELECTRIC GOVERNOR
9 420 614 633 
 
ELECTRIC GOVERNOR
9 420 614 691 
 
ELECTRIC GOVERNOR
9 420 614 805 
 
ELECTRIC GOVERNOR
 
 

Mitsubishi 

105962-0050  

105962-0051 
 
ME748572 
ELECTRIC GOVERNOR
F 019 Z6E 027 
ME748900 
ELECTRIC GOVERNOR
 
ME748573 
ELECTRIC GOVERNOR
F 019 Z6E 028 
ME748901 
ELECTRIC GOVERNOR
9 420 614 555 
ME748442 
ELECTRIC GOVERNOR
F 01G 29N 07M 
ME748763 
ELECTRIC GOVERNOR
F 019 Z6E 029 
ME748899 
ELECTRIC GOVERNOR
9 420 614 595 
ME748904 
ELECTRIC GOVERNOR
9 420 614 767 
ME748907 
ELECTRIC GOVERNOR
Back to top