Information electric governor
BOSCH
F 019 Z2E 567
f019z2e567
ZEXEL
105960-0380
1059600380
ISUZU
1157901150
1157901150

Rating:
Scheme ###:
1. | [1] | 159560-3320 | GOVERNOR HOUSING |
2. | [10] | 139006-4100 | BLEEDER SCREW |
4. | [1] | 159635-8500 | COILED SPRING |
5. | [1] | 159564-4000 | SLOTTED WASHER |
6. | [1] | 159635-8800 | SLOTTED WASHER |
7. | [1] | 159636-3121 | CONNECTOR |
7B. | [1] | 159636-3321 | CONNECTOR |
7C. | [1] | 159636-3521 | CONNECTOR |
8. | [1] | 020105-1240 | BLEEDER SCREW M5P0.8L12 |
11. | [1] | 159620-6320 | ACTUATOR |
11/2. | [1] | 159583-1020 | STRAP |
11/3. | [1] | 159563-1700 | LEVER SHAFT |
11/4. | [2] | 029311-0170 | SHIM |
11/4. | [2] | 029311-0170 | SHIM |
11/5. | [2] | 159635-0200 | O-RING |
11/5. | [2] | 159635-0200 | O-RING |
11/6. | [2] | 014011-0140 | PLAIN WASHER D22&10.5T1.6 |
11/6. | [2] | 014011-0140 | PLAIN WASHER D22&10.5T1.6 |
11/8. | [1] | 016010-0940 | LOCKING WASHER |
11/10. | [4] | 139006-9100 | BLEEDER SCREW |
11/11. | [1] | 407914-2000 | CONTROL UNIT |
11/12. | [4] | 010235-1640 | HEX-SOCKET-HEAD CAP SCREW |
11/14. | [4] | 029300-5020 | PLAIN WASHER D10&5.1T1.5 |
11/15. | [1] | 159636-0500 | LIP |
11/18. | [2] | 020105-1640 | BLEEDER SCREW M5P0.8L16 |
11/19. | [1] | 134002-0200 | ADAPTOR |
11/21. | [1] | 159583-5700 | CONTROL LEVER |
11/22. | [1] | 159563-4800 | COILED SPRING |
11/23. | [1] | 159563-1800 | BUSHING |
11/24. | [1] | 014110-8440 | LOCKING WASHER |
11/25. | [1] | 013030-8140 | UNION NUT M8P1.25H5 |
11/26. | [1] | 159563-1000 | FLAT-HEAD SCREW |
11/27. | [1] | 155615-1100 | FLAT-HEAD SCREW M6P1.0L37 |
11/28. | [2] | 029240-6010 | UNION NUT M6P1.0H5* |
11/28. | [2] | 029240-6010 | UNION NUT M6P1.0H5* |
11/32. | [2] | 020106-1440 | BLEEDER SCREW M6P1.0L14 |
11/34. | [1] | 159563-8400 | FLAT-HEAD SCREW |
11/39. | [2] | 159635-5200 | SEAL RING |
11/41. | [4] | 014110-6440 | LOCKING WASHER |
12. | [2] | 020106-4040 | BLEEDER SCREW |
13. | [1] | 159561-1300 | GOVERNOR COVER |
14. | [6] | 139006-1300 | BLEEDER SCREW M6P1L76 |
15. | [2] | 029010-6550 | BLEEDER SCREW |
16. | [8] | 014110-6440 | LOCKING WASHER |
16. | [8] | 014110-6440 | LOCKING WASHER |
17. | [1] | 159566-4401 | GASKET |
18. | [1] | 159635-0100 | GASKET |
19. | [1] | 154390-0500 | GASKET |
20. | [1] | 153021-6300 | CAP |
21. | [1] | 026524-3040 | GASKET |
22. | [1] | 159564-0800 | EYE BOLT |
23. | [2] | 139514-0000 | GASKET D19.2&14.2T1.0 |
28. | [1] | 139008-1100 | BLEEDER SCREW |
40. | [1] | 159564-0800 | EYE BOLT |
41. | [2] | 139514-0000 | GASKET D19.2&14.2T1.0 |
65. | [2] | 159635-0400 | BUSHING |
80. | [1] | 159586-6500 | TOOTHED GEAR |
81. | [1] | 014111-2420 | LOCKING WASHER |
82. | [1] | 013031-2120 | UNION NUT |
83. | [1] | 025803-1310 | WOODRUFF KEY |
84. | [1] | 155412-5200 | IMPELLER WHEEL |
804S. | [1] | 159911-2300 | PLUG HOUSING |
805S. | [1] | 159911-2400 | PLUG HOUSING |
806S. | [1] | 159911-2500 | PLUG HOUSING |
Include in #1:
108622-1250
as GOVERNOR
Cross reference number
Zexel num
Bosch num
Firm num
Name
Information:
Test 1 - Overspeed Switch (OS)
Table 1
Overspeed Switch (OS)
Step Engine RPM Action Correct Result
A 25 + 5 rpm less than 75% Overspeed Verify rpm Press the 75% Verify button No engine shutdown
B 25 + 5 rpm more than 75% Overspeed Verify rpm Press the 75% Verify button Air and fuel shutoff
C Manually reset the air shutoff lever at the top of the air inlet, if equipped. Press the ESS reset button. Test 2 - Emergency Stop Switch (ES)
Table 2
Emergency Stop Switch (ES)
Step Engine RPM Action Correct Result
A Any rpm above the crank terminate rpm Press the push button for the emergency stop switch Air and fuel shutoff
B Manually reset the air shutoff lever at the top of the air inlet, if equipped. Turn ES switch in the dirction that is shown on the face of the push button in order to reset the switch. Test 3 - Normal Stop Switch (NSS)
Table 3
Normal Stop Switch (NSS)
Step Engine RPM Action Correct Result
A Any rpm above the crank terminate rpm Push the normal stop switch (NSS) Fuel shutoff Test 4 - Water Temperature Contactor Switch
Table 4
Water Temperature Contactor Switch (WTS)
Step Engine RPM Action Correct Result
A Any rpm above the crank terminate rpm Place a jumper across terminals TS-2 and TS-7. Fuel shutoff
B Remove the jumper from terminals TS-2 and TS-7. Test 5 - Oil Pressure Switch (OPS1)
Table 5
Oil Pressure Switch (OPS1)
Step Engine RPM Action Correct Result
A Any rpm above the crank terminate rpm Place a jumper across terminals OPS1-1 and OPS1-3. Fuel shutoff
B Remove the jumper from terminals OPS1-1 and OPS1-3. Test 6 - Oil Pressure Switch (OPS2)
Table 6
Oil Pressure Switch (OPS2)
Step Engine RPM Action Correct Result
A 25 + 5 rpm less than the setting for the oil step speed Place a jumper across terminals OPS2-1 and OPS2-3. No engine shutdown.
B 25 + 5 rpm more than the setting for the oil step speed Place a jumper across terminals OPS2-1 and OPS2-3. Fuel shutoff 9 seconds after the oil step speed is reached.
C Remove the jumper from across terminals OPS2-1 and OPS2-3.
Table 1
Overspeed Switch (OS)
Step Engine RPM Action Correct Result
A 25 + 5 rpm less than 75% Overspeed Verify rpm Press the 75% Verify button No engine shutdown
B 25 + 5 rpm more than 75% Overspeed Verify rpm Press the 75% Verify button Air and fuel shutoff
C Manually reset the air shutoff lever at the top of the air inlet, if equipped. Press the ESS reset button. Test 2 - Emergency Stop Switch (ES)
Table 2
Emergency Stop Switch (ES)
Step Engine RPM Action Correct Result
A Any rpm above the crank terminate rpm Press the push button for the emergency stop switch Air and fuel shutoff
B Manually reset the air shutoff lever at the top of the air inlet, if equipped. Turn ES switch in the dirction that is shown on the face of the push button in order to reset the switch. Test 3 - Normal Stop Switch (NSS)
Table 3
Normal Stop Switch (NSS)
Step Engine RPM Action Correct Result
A Any rpm above the crank terminate rpm Push the normal stop switch (NSS) Fuel shutoff Test 4 - Water Temperature Contactor Switch
Table 4
Water Temperature Contactor Switch (WTS)
Step Engine RPM Action Correct Result
A Any rpm above the crank terminate rpm Place a jumper across terminals TS-2 and TS-7. Fuel shutoff
B Remove the jumper from terminals TS-2 and TS-7. Test 5 - Oil Pressure Switch (OPS1)
Table 5
Oil Pressure Switch (OPS1)
Step Engine RPM Action Correct Result
A Any rpm above the crank terminate rpm Place a jumper across terminals OPS1-1 and OPS1-3. Fuel shutoff
B Remove the jumper from terminals OPS1-1 and OPS1-3. Test 6 - Oil Pressure Switch (OPS2)
Table 6
Oil Pressure Switch (OPS2)
Step Engine RPM Action Correct Result
A 25 + 5 rpm less than the setting for the oil step speed Place a jumper across terminals OPS2-1 and OPS2-3. No engine shutdown.
B 25 + 5 rpm more than the setting for the oil step speed Place a jumper across terminals OPS2-1 and OPS2-3. Fuel shutoff 9 seconds after the oil step speed is reached.
C Remove the jumper from across terminals OPS2-1 and OPS2-3.