105960-0372 ZEXEL F 019 Z3E 080 BOSCH ELECTRIC GOVERNOR f019z3e080 1059600372 1157900901


 

Information electric governor

BOSCH F 019 Z3E 080 f019z3e080
ZEXEL 105960-0372 1059600372
ISUZU 1157900901 1157900901
105960-0372 ELECTRIC GOVERNOR
Rating:
79
Buy ELECTRIC GOVERNOR 105960-0372 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 159560-0100 GOVERNOR HOUSING
2. [8] 139006-4100 BLEEDER SCREW
3. [1] 029621-7050 PACKING RING
4. [1] 159635-8500 COILED SPRING
5. [1] 159564-4000 SLOTTED WASHER
6. [1] 159564-4100 SLOTTED WASHER
7. [1] 159636-3121 CONNECTOR
7B. [1] 159636-3321 CONNECTOR
7C. [1] 159636-3521 CONNECTOR
8. [1] 020105-1240 BLEEDER SCREW M5P0.8L12
11. [1] 159620-6222 ACTUATOR
11/1. [1] 159562-3820 PLATE;GOV.
11/2. [1] 159583-1020 STRAP
11/3. [1] 159563-1700 LEVER SHAFT
11/4. [2] 029311-0170 SHIM
11/4. [2] 029311-0170 SHIM
11/5. [2] 159635-0200 O-RING
11/5. [2] 159635-0200 O-RING
11/6. [2] 014011-0140 PLAIN WASHER D22&10.5T1.6
11/6. [2] 014011-0140 PLAIN WASHER D22&10.5T1.6
11/8. [1] 016010-0940 LOCKING WASHER
11/9. [1] 159635-8621 LINEAR DC MOTOR
11/10. [4] 139006-9100 BLEEDER SCREW
11/11. [1] 407914-2000 CONTROL UNIT
11/12. [4] 010235-1640 HEX-SOCKET-HEAD CAP SCREW
11/14. [4] 029300-5020 PLAIN WASHER D10&5.1T1.5
11/15. [1] 159636-0500 LIP
11/16. [1] 159635-9300 GROMMET
11/17. [1] 159630-5320 CABLE SET
11/18. [2] 020105-1640 BLEEDER SCREW M5P0.8L16
11/19. [1] 134002-0200 ADAPTOR
11/21. [1] 159583-5600 CONTROL LEVER
11/22. [1] 159563-4800 COILED SPRING
11/23. [1] 159563-1800 BUSHING
11/24. [1] 014110-8440 LOCKING WASHER
11/25. [1] 013030-8140 UNION NUT M8P1.25H5
11/26. [1] 159563-1000 FLAT-HEAD SCREW
11/27. [1] 155615-1700 FLAT-HEAD SCREW
11/28. [2] 029240-6010 UNION NUT M6P1.0H5*
11/28. [2] 029240-6010 UNION NUT M6P1.0H5*
11/29. [1] 159635-5400 BRACKET
11/30. [1] 479765-6820 PULSE GENERATOR
11/31. [1] 159635-0300 UNION NUT
11/32. [2] 020106-1440 BLEEDER SCREW M6P1.0L14
11/34. [1] 159563-8400 FLAT-HEAD SCREW
11/38. [1] 159635-5520 COVER
11/39. [2] 159635-5200 SEAL RING
11/39. [2] 159635-5200 SEAL RING
11/40. [4] 020106-2840 BLEEDER SCREW
12. [2] 020106-4040 BLEEDER SCREW
13. [1] 159561-1400 GOVERNOR COVER
14. [6] 139006-1300 BLEEDER SCREW M6P1L76
15. [2] 029010-6550 BLEEDER SCREW
16. [8] 014110-6440 LOCKING WASHER
16. [8] 014110-6440 LOCKING WASHER
17. [1] 154371-5600 GASKET
18. [1] 159635-0100 GASKET
19. [1] 154390-0500 GASKET
20. [1] 153021-5000 CAP
21. [1] 026524-3040 GASKET
22. [1] 159564-0800 EYE BOLT
23. [2] 139514-0000 GASKET D19.2&14.2T1.0
30. [1] 159586-7820 BRACKET
31. [3] 020106-1240 BLEEDER SCREW M6P1.0L12
32. [1] 159586-2600 CLAMPING BAND
33. [2] 020106-1240 BLEEDER SCREW M6P1.0L12
65. [2] 159635-0400 BUSHING
80. [1] 159586-6400 TOOTHED GEAR
81. [1] 014111-2420 LOCKING WASHER
82. [1] 013031-2120 UNION NUT
83. [1] 025803-1310 WOODRUFF KEY
804S. [1] 159911-2300 PLUG HOUSING
805S. [1] 159911-2400 PLUG HOUSING
806S. [1] 159911-2500 PLUG HOUSING

Include in #1:

106682-1053 as GOVERNOR

Cross reference number

Zexel num
Bosch num
Firm num
Name
105960-0372 
F 019 Z3E 080 
1157900901  ISUZU
ELECTRIC GOVERNOR
K 14JU ELECTRIC GOVERNOR GOV




Information:

Problem 4
The starting motor remains engaged or the starting motor continues to run after the engine is running.
Check the components of the starting circuit.
Measure the voltages at terminal (TS-26) of the junction box while the engine is running.Result
The voltage at the terminal is zero volts.The problem is in the starting motor (SM), the pinion solenoid (PS), or the magnetic switch (MS). Repair the faulty component. STOP.
The voltage at the terminal is between 15 volts and 32 volts.The START terminals of the start/stop switch are normally closed. This is normal for an automatic start system. In a manual start system, the switches should be normally open. The switch is on terminals (SSS-1) and (SSS-2) for a normal start/stop switch. Repair the faulty switch. STOP.Problem 5
The engine shutdown occurs after the engine runs for more than 3 minutes.
Check the protection switches.
Remove the jumper that is between terminals (TS-9) and (TS-10) of the junction box.
If the engine is equipped with a low oil pressure indicator, disconnect the diode that is between terminals (TS-8) and (TS-10). The cathode lead of the diode should be connected to terminal (TS-10).
If the engine is equipped with a low oil pressure indicator, ensure that a jumper is not installed between terminals (TS-8) and (TS-9).
Start the engine.
Reconnect the jumper that is between terminals (TS-9) and (TS-10) of the junction box after the test is completed.Result
The engine starts and the engine runs.The problem is in the oil pressure switch or the water temperature contactor switch. Go to Step 5 of "Problem 1".
The engine starts but engine shutdown occurs immediately.Go to Step 1 of "Problem 3".
The engine starts and the engine runs but engine shutdown occurs after the engine runs for more than 3 minutes.Go to Step 2.
The engine cranks but the engine does not start.Go to Step 1 of "Problem 1".
Check the start/stop switch and slave relay (SR1).
Disconnect the wire in the junction box that connects terminal (SR1-85) of the slave relay (SR1) to terminal (TD-7) of the time delay relay (TD).
Crank the engine. Activate the emergency stop switch, if necessary.Result
The engine starts and the engine runs.The start/stop switch has a short circuit or a wiring problem is causing a voltage at terminal (TD-7). Reconnect the wire to the terminal. STOP.
Engine shutdown still occurs after several minutes.The contacts of (SR1) periodically close. The problem may also be with the governor or the fuel supply to the engine. Refer to the Engine Service Manual. If a 2301A Electric Governor is used, the SR1 contacts may be opening. Refer to 2301A Electric Governor Service Manual, SENR3585. Test SR1. Refer to Testing and Adjusting, "Slave Relay Test".Problem 6
Engine shutdown does not occur when a fault is detected.
Check the protection switches and the crank terminate switch of the electronic speed switch.
Reset circuit breaker (CB7).
Start the engine and run the engine at low idle.
Contact with electrical components can cause injury or death.Remove all jewelry and avoid contact with electrical components. Use properly insulated tools when working on the junction box of an

Have questions with 105960-0372?





Group cross 105960-0372 ZEXEL

Mitsubishi 

F 019 Z1E 917 
ME755395 
ELECTRIC GOVERNOR
F 019 Z9E 203 
ME756281 
ELECTRIC GOVERNOR
F 019 Z1E 971 
ME755526 
ELECTRIC GOVERNOR
F 019 Z4E 077 
ME756217 
ELECTRIC GOVERNOR

Nissan-Diesel 

F 019 Z1E 920 
1910695Z00 
ELECTRIC GOVERNOR
 
 
ELECTRIC GOVERNOR

Isuzu 

F 019 Z2E 569 
1157901061 
ELECTRIC GOVERNOR
F 019 Z2E 992 
1157901062 
ELECTRIC GOVERNOR

Nissan-Diesel 

F 019 Z2E 037 
19106NB000 
ELECTRIC GOVERNOR

Hino 

F 019 Z2E 021 
224002060A 
ELECTRIC GOVERNOR

Isuzu 

F 019 Z2E 701 
1157901070 
ELECTRIC GOVERNOR
F 019 Z3E 021 
 
ELECTRIC GOVERNOR

Isuzu 

F 019 Z2E 632 
1157900900 
ELECTRIC GOVERNOR
F 019 Z2E 766 
 
ELECTRIC GOVERNOR

Isuzu 

105960-0372  
F 019 Z3E 080 
1157900901 
ELECTRIC GOVERNOR
F 019 Z2E 567 
1157901150 
ELECTRIC GOVERNOR
 
 
ELECTRIC GOVERNOR
F 019 Z2F 552 
 
ELECTRIC GOVERNOR

Isuzu 

F 019 Z2E 600 
1157901040 
ELECTRIC GOVERNOR
F 019 Z3E 219 
1157901041 
ELECTRIC GOVERNOR
F 019 Z3E 380 
1157901042 
ELECTRIC GOVERNOR
Back to top