159595-3821 ZEXEL 9 443 610 475 BOSCH DIAPHRAGM HOUSING 9443610475 1595953821 227131120a


 

Information diaphragm housing

BOSCH 9 443 610 475 9443610475
ZEXEL 159595-3821 1595953821
HINO 227131120A 227131120a
159595-3821 DIAPHRAGM HOUSING
Rating:
72
Buy DIAPHRAGM HOUSING 159595-3821 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
159595-3821 
9 443 610 475 
227131120A  HINO
DIAPHRAGM HOUSING
C 14GH HOUSING GOV
159595-3821 
9 443 610 475 
ME740780  MITSUBISHI
DIAPHRAGM HOUSING
C 14GH HOUSING GOV
159595-3821 
9 443 610 475 
1927099104  NISSAN-DIESEL
DIAPHRAGM HOUSING
C 14GH HOUSING GOV




Information:

Test Points (Voltages And Waveforms)
dc Voltages Conditions: 1. dc input voltage applied to POWER connector as shown.2. CALIBRATION CHECK/OPERATE switch in the OPERATE position.3. Neither transducer connected to indicator.4. TPI is reference for all voltages.Equipment Required: 6V3030 Digital Multimeterdc Input Voltages Waveforms Conditions: 1. dc power input voltage of 25 1 Volts.2. CALIBRATION CHECK/OPERATE switch in the CHECK position (can be held in CHECK position with tape).3. Neither transducer connected to indicator.4. TPI is reference for all waveforms.Equipment Required: dc oscilloscope (dual channel preferred). Waveform Time Relationships
VOLTAGES MAY VARY 10%, PULSE DURATIONS BY 20% EXCEPT 2.66 ms WHICH IS BASED ON A 12.000 kHz OSCILLATOR FREQ. (1C202). SIGNAL SOURCE IS INTERNAL CALIBRATOR. ALL TEST POINTS REFERENCED TO TP1.Waveform Time Relationships (enlarged scale)
VOLTAGES MAY VARY 10%, PULSE DURATIONS BY 20% EXCEPT 83.3 ?s AND 2.66 ms WHICH ARE EXACT BASED ON A 12.000 kHZ OSCILLATOR. (1C202) SIGNAL SOURCE IS INTERNAL CALIBRATOR. ALL TEST POINTS REFERENCED TO TP1.Disassembly Procedure
1 Remove six screws (1) from front panel (2), and remove panel (2) from case (3). Remove four screws (4) from the PC board, and also remove the locknuts from the two front panel switches (5) and (6). Carefully lift front panel (2) from PC (printed circuit) board (7).Calibration Procedure
To make sure the 6V3100 Timing Indicator Group (1) has good accuracy, check its calibration at a minimum of every six months. Also, the timing indicator will need calibration if: A. It does not show 2000 30 R/MIN at (A) and 32.0 .2 DEG at (B), when the CALIBRATION CHECK-OPERATE Switch (C) is in the CALIBRATION CHECK position. With no input signal at (D) or (E), the reading at R/MIN location (A) must show three zeros (000). If four zeros (0000) show, it is an indication of a possible need for calibration of the unit. This error only is not reason enough to do a complete calibration procedure. It is also not necessary to do a complete calibration procedure if the reading at the DEG location (B) has a decimal point as shown, (00.0) in addition to the three zeros.B. Reading is different than (000) at either location (A) or (B).All calibrations can be done with the use of a small screwdriver, a frequency counter and

Have questions with 159595-3821?





Group cross 159595-3821 ZEXEL

Mitsubishi 

9 443 610 918 
ME738395 
DIAPHRAGM HOUSING

Nissan-Diesel 

9 443 610 918 
1927099102 
DIAPHRAGM HOUSING

Hino 

159595-3821  
9 443 610 475 
227131120A 
DIAPHRAGM HOUSING

Mitsubishi 

159595-3821  
9 443 610 475 
ME740780 
DIAPHRAGM HOUSING

Nissan-Diesel 

159595-3821  
9 443 610 475 
1927099104 
DIAPHRAGM HOUSING
Back to top