19100-05510 PUMP ASSY, INJECTI Denso Cross


 

Information pump assy, injecti

Nozzle: 0935002710
19100-05510 PUMP ASSY, INJECTI
Rating:
76
Buy PUMP ASSY, INJECTI 19100-05510 genuine, new aftermarket engine parts with delivery

KIT List:

Body assy, injecti 1904400360
Pump assy, fuel fe 1922900060
Governor assy, mec 1908900170

Include in #3:

Number on scheme 000
PUMP ASSY, INJECTI
19100-05511 as PUMP ASSY, INJECTI

Cross reference number



Part num Firm num Firm Name
19100-05510  61507-1272  PUMP ASSY, INJECTI
61507-12721    KOMATSU PUMP ASSY, INJECTI




Information:


Table 1
Revision Summary of Changes
01 Updated Illustration 1
02 Updated effectivity Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
Inadequate battery negative bonding to engine block causing incorrect diagnostic codes/tripping in the units that are disconnected from the engine-mounted charging alternator.Solution
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.
Illustration 1 g06575359
Generator set isolated DC supply system
(1) Electronic subsystem 1
(2) Electronic subsystem 2
(3) Electronic subsystem 3
(4) Generator set subsystem loads
(5) Engine ECM
(6) Starter
(7) Electronics power buss
(8) Electronics single point ground
(9) 12AWG (4 Sq.mm) bonding jumper (multi strand) wire
(10) Battery disconnect switch
(11) Customer ground connection
(12) Battery
(13) Battery charger
(14) Customer scopeNote: The red color connections in Illustration 1 are to be connected at customer site. Connections should be made after the battery disconnect switch (10).Caterpillar is aware of the problem, and is recommending the following interim solution.Install a 12AWG (4 Sq.mm) bonding jumper (multi strand) wire (9) connecting all electrical sensor grounding points (8) at the power distribution box to the customer ground connection (11). Refer to Illustration 1.Reference: Refer to Special Instruction, REHS4634, "Grounding Design Guide for Electric Power Generation Products".