19100-04920 PUMP ASSY, INJECTI Denso Cross


 

Information pump assy, injecti

Nozzle: 0935003190
19100-04920 PUMP ASSY, INJECTI
Rating:
13
Buy PUMP ASSY, INJECTI 19100-04920 genuine, new aftermarket engine parts with delivery

KIT List:

Body assy, injecti 1904400300
Pump assy, fuel fe 1922900060
Governor assy, mec 1908900250

Components :

001. PUMP ASSY, INJECTI 19100-04920
002. BODY ASSY, INJECTI 09010-07820
003. PUMP ASSY, FUEL FE 09210-01291
004. GOVERNOR ASSY, MEC 19080-00750
004. GOVERNOR ASSY, MEC 19080-00750

Scheme ###:

000. [01] 19100-04920 PUMP ASSY, INJECTI 30661-71070
005. [01] 09010-07820 BODY ASSY, INJECTI
006. [01] 19080-00750 GOVERNOR ASSY, MEC
007. [01] 09210-01291 PUMP ASSY, FUEL FE 34461-09060
008. [01] 09001-80081 COVER, CONTROL RAC 09001-80081
009. [01] 94905-02450 NUT, HEXAGON 94905-02450
010. [01] 94913-00190 KEY, WOODRUFF 94913-00190
011. [06] 94904-70620 BOLT, W/WASHER
012. [01] 94901-50500 WASHER, SPRING 94901-50500

Include in #3:

19100-04920 as PUMP ASSY, INJECTI

Cross reference number



Part num Firm num Firm Name
19100-04920  30661-7107  PUMP ASSY, INJECTI
30661-71070    MITSUBISHI PUMP ASSY, INJECTI




Information:

Condition: DEF nozzle does not shut off, causing DEF to exit the tank breather
Troubleshooting Steps:
Machine should be parked on level surface during DEF fill. Parking the machine with front end running at a downward angle may cause DEF to exit breather before the float in the tank valve rises enough to shut off nozzle.
Verify that the pressure at the nozzle from supply pump meets minimum 172 to 200 kPa (25 to 29 psi) requirement to trigger nozzle shut off.
Inspect tank-mounted valve for debris or ice preventing closure.
Inspect nozzle for damage from rough handling, DEF crystal buildup. Replace or repair as needed.Condition: DEF Nozzle shuts off before tank is full
Troubleshooting Steps:
Machine should be parked on level surface during DEF fill. Parking the machine with front end running at an upward angle may cause DEF Nozzle to shut off prematurely because DEF level at the rear of the tank near valve may cause float to rise and shut off nozzle.
Verify that flow at nozzle does not exceed the recommended target of 45 L/min (12 US gpm).
Excessive flow can damage tank-mounted valve and cause premature shut off.
Inspect vent line going up to breather and breather for any blockage, clean or replace if needed.
Inspect DEF fast fill line from receiver to valve, the valve for any blockages. Clean or replace if needed.
Inspect nozzle for damage from rough handling, DEF crystal buildup. Repair or replace as needed.

Have questions with 19100-04920?





Group cross 19100-04920

Back to top