19100-04593 PUMP ASSY, INJECTI Denso Cross


 

Information pump assy, injecti

19100-04593 PUMP ASSY, INJECTI
Rating:
34
Buy PUMP ASSY, INJECTI 19100-04593 genuine, new aftermarket engine parts with delivery

Components :

001. PUMP ASSY, INJECTI 19100-04593
002. BODY ASSY, INJECTI 09010-05700
003. BODY ASSY, INJECTI 09010-09960
004. GOVERNOR ASSY, MEC 09130-01990
005. TIMER ASSY, AUTOMA 09180-01281
005. TIMER ASSY, AUTOMA 09180-01281
006. PUMP ASSY, FUEL FE 09210-01440

Scheme ###:

000. [01] 19100-04593 PUMP ASSY, INJECTI ME076009
005. [01] 09010-05700 BODY ASSY, INJECTI ME702012
005. [01] 09010-09960 BODY ASSY, INJECTI ME736047
006. [01] 09130-01990 GOVERNOR ASSY, MEC ME703675
007. [01] 09001-80081 COVER, CONTROL RAC ME702034
008. [01] 94914-02840 O-RING MH035502
009. [01] 09006-00050 COVER SUB-ASSY, TI ME036902
010. [01] 09180-01281 TIMER ASSY, AUTOMA ME036901
011. [04] 94905-02680 NUT, HEXAGON ME702046
012. [05] 90258-10001 WASHER, SPRING MC327716
013. [04] 94901-15020 WASHER, STEEL PLAT ME702042
014. [01] 94913-00210 KEY, WOODRUFF ME702047
015. [01] 94901-40210 WASHER, COUNTERSUN ME702043
016. [01] 09001-20220 NUT, TIMER ROUND ME702033
017. [01] 09210-01440 PUMP ASSY, FUEL FE ME035928
018. [01] 09009-20100 BRACKET ME702036
019. [01] 94904-73910 BOLT, W/WASHER ME703449
020. [05] 94904-72690 BOLT, W/WASHER ME702045
021. [01] 94904-04300 BOLT, HEXAGON ME702044
022. [01] 09028-50021 CAP ME035845
023. [01] 09009-20140 BRACKET ME702037
024. [01] 91266-10081 NUT, HEXAGON MF430122
025. [01] 09028-50050 CAP ME076458

Include in #3:

19100-04593 as PUMP ASSY, INJECTI

Cross reference number



Part num Firm num Firm Name
19100-04593  ME076009  PUMP ASSY, INJECTI




Information:

Condition: DEF nozzle does not shut off, causing DEF to exit the tank breather
Troubleshooting Steps:
Machine should be parked on level surface during DEF fill. Parking the machine with front end running at a downward angle may cause DEF to exit breather before the float in the tank valve rises enough to shut off nozzle.
Verify that the pressure at the nozzle from supply pump meets minimum 172 to 200 kPa (25 to 29 psi) requirement to trigger nozzle shut off.
Inspect tank-mounted valve for debris or ice preventing closure.
Inspect nozzle for damage from rough handling, DEF crystal buildup. Replace or repair as needed.Condition: DEF Nozzle shuts off before tank is full
Troubleshooting Steps:
Machine should be parked on level surface during DEF fill. Parking the machine with front end running at an upward angle may cause DEF Nozzle to shut off prematurely because DEF level at the rear of the tank near valve may cause float to rise and shut off nozzle.
Verify that flow at nozzle does not exceed the recommended target of 45 L/min (12 US gpm).
Excessive flow can damage tank-mounted valve and cause premature shut off.
Inspect vent line going up to breather and breather for any blockage, clean or replace if needed.
Inspect DEF fast fill line from receiver to valve, the valve for any blockages. Clean or replace if needed.
Inspect nozzle for damage from rough handling, DEF crystal buildup. Repair or replace as needed.