19000-08920 PUMP ASSY, INJECTI Denso Cross


 

Information pump assy, injecti

Nozzle: 0935002360
19000-08920 PUMP ASSY, INJECTI
Rating:
21
Buy PUMP ASSY, INJECTI 19000-08920 genuine, new aftermarket engine parts with delivery

KIT List:

Body assy, injecti 1904400320
Governor assy, mec 1908900170
Pump assy, fuel fe 1922900060
Pump assy, fuel fe 1922900060

Components :

001. PUMP ASSY, INJECTI 19000-08920
002. BODY ASSY, INJECTI 09010-04980
003. GOVERNOR ASSY, MEC 09080-07750
004. PUMP ASSY, FUEL FE 09210-01320
005. PUMP ASSY, FUEL FE 09210-01870

Scheme ###:

000. [01] 19000-08920 PUMP ASSY, INJECTI 61347-21200
005. [01] 09010-04980 BODY ASSY, INJECTI
006. [01] 09080-07750 GOVERNOR ASSY, MEC
007. [01] 09001-80140 COVER, CONTROL RAC
008. [01] 94905-02450 NUT, HEXAGON
009. [01] 94913-00050 KEY, WOODRUFF
010. [01] 94901-50500 WASHER, SPRING
012. [01] 09210-01870 PUMP ASSY, FUEL FE
012. [01] 09210-01320 PUMP ASSY, FUEL FE
013. [01] 91518-08221 BOLT, W/WASHER
014. [05] 91418-06161 BOLT, W/WASHER
016. [01] 91518-06121 BOLT, W/WASHER
017. [01] 09006-10011 COVER, PRIMING PUM
018. [01] 09257-50100 SHAFT, SPLINE 61347-11470

Include in #3:

19000-08920 as PUMP ASSY, INJECTI

Cross reference number



Part num Firm num Firm Name
19000-08920  61347-2120  PUMP ASSY, INJECTI
61347-21200    KOMATSU PUMP ASSY, INJECTI




Information:

Operation of ATAAC
Heated compressed air from the engine turbocharger is conveyed to an air-to-air aftercooler that is positioned in front of the engine radiator. The combined effect of the engine fan and ram air moves cooled air through the system to reduce the turbocharged air temperature before it enters the engine intake manifold.Lower intake air temperature allows more air to enter the cylinder, resulting in more complete fuel combustion and reduced exhaust emissions.Air-to-air aftercoolers can achieve charge air temperatures lower than water-to-air systems for additional efficiency.
To maintain an adequate water pump cavitation temperature for efficient water pump performance in an Air-to-Air aftercooled engine, Caterpillar recommends that the coolant mix contain a minimum of 30% Caterpillar Antifreeze, GM-6038M or equivalent. Only use a greater concentration (above 30%) of antifreeze as needed for anticipated outside temperatures.Ethylene glycol raises the boiling point of water.Do not exceed a coolant mixture of 60% ethylene glycol to water since a concentration above 60% ethylene glycol will reduce the engine's freeze protection and increase the possibility of deposit formation in the cooling system.Dowtherm 209 Full-Fill coolant cannot be substituted for ethylene glycol, due to its inability to raise the water pump cavitation temperature. Dowtherm 209 Full-Fill coolant lowers the boiling point of water.
Air Intake System
Never run the engine without an air cleaner installed or with a damaged air cleaner. Dirt will enter the engine and cause premature wear and damage to engine components.Service the air cleaner at regular intervals as determined by the operating environmental dust conditions. Check the air cleaner service indicator (if equipped) daily.As the air cleaner element becomes plugged, the difference of air pressure between the inlet side (dirty side) and the engine side (clean side) will increase. Service the air cleaners regularly or when the air cleaner service indicator diaphragm enters the red zone or the red piston locks in the visible position.Inspect the air intake hoses, elbows and gaskets for cracks or damage, replace as needed. Check for loose clamps, tighten as needed.Check the precleaner (if equipped) daily for accumulation of dust and debris.The Caterpillar air cleaner element may be cleaned up to six times, but must be replaced annually. The element when cleaned, should be thoroughly checked for rips and tears in the filter material and for gasket damage.Winter Fronts
Caterpillar discourages the use of winter fronts or other air flow restriction devices mounted in front of radiators with air-to-air aftercooled engines. Air flow restriction can cause higher exhaust temperatures, power loss, excessive fan usage, a reduction in fuel economy and possible engine damage.If a winter front must be used, then it should have a permanent circular or diamond-shaped opening directly in line with the fan hub and must have a minimum opening dimension of at least 120 sq. in. (770 sq. cm).A centered opening, versus a side or edge winter front opening is specified to provide sensing when viscous fan drives are used and/or to prevent an interrupted air flow on the fan blades that could cause a fan

Have questions with 19000-08920?





Group cross 19000-08920

Back to top