19000-08244 PUMP ASSY, INJECTI Denso Cross


 

Information pump assy, injecti

19000-08244 PUMP ASSY, INJECTI
Rating:
23
Buy PUMP ASSY, INJECTI 19000-08244 genuine, new aftermarket engine parts with delivery

Components :

001. PUMP ASSY, INJECTI 19000-08244
001. PUMP ASSY, INJECTI 19000-08244
002. SWITCH KIT, CONTRO 09009-90450
003. BODY ASSY, INJECTI 09010-05700
004. BODY ASSY, INJECTI 09010-09960
005. GOVERNOR ASSY, MEC 09130-00841
006. TIMER ASSY, AUTOMA 09180-01281
006. TIMER ASSY, AUTOMA 09180-01281
007. PUMP ASSY, FUEL FE 09210-01440

Scheme ###:

000. [01] 19000-08243 PUMP ASSY, INJECTI ME035567
000. [01] 19000-08244 PUMP ASSY, INJECTI ME035567
005. [01] 09010-05701 BODY ASSY, INJECTI ME702012
005. [01] 09010-09960 BODY ASSY, INJECTI ME736047
006. [01] 09130-00844 GOVERNOR ASSY, MEC ME702013
007. [01] 09001-80081 COVER, CONTROL RAC ME702034
008. [01] 94914-02840 O-RING MH035502
009. [01] 09006-00050 COVER SUB-ASSY, TI ME036902
010. [01] 09180-01281 TIMER ASSY, AUTOMA ME036901
011. [04] 94905-02680 NUT, HEXAGON ME702046
012. [04] 90258-10001 WASHER, SPRING MC327716
013. [04] 94901-15020 WASHER, STEEL PLAT MH005068
015. [01] 94913-00210 KEY, WOODRUFF ME702047
016. [01] 94901-40210 WASHER, COUNTERSUN ME702043
017. [01] 09001-20220 NUT, TIMER ROUND ME702033
019. [01] 09210-01440 PUMP ASSY, FUEL FE ME035928
020. [01] 09009-20100 BRACKET ME702036
021. [01] 94904-73910 BOLT, W/WASHER ME703449
023. [04] 94904-72690 BOLT, W/WASHER ME702045
024. [02] 91418-06201 BOLT, W/WASHER ME702041
025. [01] 09009-90450 SWITCH KIT, CONTRO ME702011
026. [01] 09028-50021 CAP ME035845
027. [01] 09009-20140 BRACKET ME702037
028. [01] 91266-10081 NUT, HEXAGON MF430122
029. [01] 09028-50050 CAP ME076458

Include in #3:

19000-08244 as PUMP ASSY, INJECTI

Cross reference number



Part num Firm num Firm Name
19000-08244  ME035567  PUMP ASSY, INJECTI




Information:

Above 0°C (32°F)
1. Place the transmission or other power takeoff attachments in NEUTRAL. For air start systems; check the air supply before starting the engine. There must be 690 kPa (100 psi) air pressure available.2. Move governor control lever (throttle) or depress the accelerator to half engine speed position.3. Turn the battery disconnect switch (if equipped) to the ON position. 4. Push the air start knob (1) IN, or ... ... turn the start switch (2) for marine, industrial and generator set engines or ... ... turn the start switch (3) for machines (vehicles) to the START position.
Do not crank the engine for more than 30 seconds. Allow 2 minutes for the starter to cool before cranking again. If oil pressure does not rise within 15 seconds after the engine starts, stop the engine and make necessary corrections.
5. Release the start switch or air start knob when the engine starts.6. Do not apply load to the engine or increase engine speed until oil pressure and all temperature gauges reach operating temperature. Check all gauges during the warm-up period.Below 0°C (32°F)
Ether is poisonous and flammable.Do not store replacement cylinders in living areas or in the operator's compartment.Do not smoke while changing ether cylinders.Use ether only in well ventilated areas.Use it with care to avoid fires.Avoid breathing of the vapors or repeated contact of ether with skin.Do not puncture or burn cylinders.Discard cylinders in a safe place.Keep ether container away from heat, sparks, open flame, or open sunlight. It may explode.Do not store replacement cylinders at temperatures above 49°C (120°F).Do not use cylinders in environments above 93°C (200°F).
1. Depress ether switch and hold for 3 seconds, then release. For air start system; check the air supply before starting the engine. There must be 690 kPa (100 psi) air pressure available.2. Push the air start knob IN or turn the start switch for engines, or turn the start switch for machines (vehicles) to the START position.3. Begin cranking the engine, and depress ether switch and hold for 3 seconds then release. Additional injections of ether may be required to start and/or achieve low idle speed.4. Operate the engine at low speed and/or load until all systems reach operating temperatures. Check all gauges during the warmup period.
Do not use excessive starting fluid during starting or after the engine is running. Do not crank the engine for more than 30 seconds. Allow 2 minutes for the starter motor to cool before cranking again.If oil pressure does not rise within 15 seconds after the engine starts, stop the engine and make necessary corrections.
Turn the battery disconnect switch (if equipped) OFF after the engine is stopped to prevent battery discharge while starter motor is cooling.For starting below -18°C (0°F), use of optional cold weather starting aids are recommended. A coolant heater or extra battery capacity may be required.For temperatures below -23°C (-10°F), consult your Caterpillar dealer or refer to the "Cold Weather Operation Guide," Form SEBU5338, available from your Caterpillar dealer.

Have questions with 19000-08244?