Information pump assy, injecti
Nozzle:
0935002180

Rating:
KIT List:
Body assy, injecti | 1904400380 |
Governor assy, mec | NO APPLICATION |
Timer assy, automa | 0918030010 |
Pump assy, fuel fe | 1922900060 |
Components :
001. | PUMP ASSY, INJECTI | 19000-07860 |
002. | BODY ASSY, INJECTI | 09010-04131 |
003. | COVER, BEARING | 09020-10430 |
004. | GOVERNOR ASSY, MEC | 09080-08720 |
005. | TIMER ASSY, AUTOMA | 09180-01271 |
005. | TIMER ASSY, AUTOMA | 09180-01271 |
006. | PUMP ASSY, FUEL FE | 09210-00942 |
007. | COUPLING ASSY | 09250-00334 |
007. | COUPLING ASSY | 09250-00334 |
008. | COUPLING ASSY | 09250-00681 |
Scheme ###:
000. | [01] | 19000-07860 | PUMP ASSY, INJECTI | 22030-1670 |
000. | [01] | 19000-07860 | PUMP ASSY, INJECTI | S2203-01670 |
003. | [01] | 09010-04132 | BODY ASSY, INJECTI | 22110-1700A |
004. | [01] | 09080-08720 | GOVERNOR ASSY, MEC | 22330-1220A |
005. | [02] | 94904-70620 | BOLT, W/WASHER | 22815-1620A |
006. | [01] | 09001-80420 | COVER, CONTROL RAC | 22114-1240A |
007. | [01] | 09180-01271 | TIMER ASSY, AUTOMA | 22510-1460A |
008. | [01] | 09001-20230 | NUT, TIMER ROUND | 22825-1110A |
009. | [01] | 90801-40280 | O-RING | 22817-1050A |
010. | [01] | 94901-40070 | WASHER, COUNTERSUN | 22877-1190A |
011. | [01] | 90458-05750 | KEY, WOODRUFF | 22891-1070A |
012. | [01] | 09210-00942 | PUMP ASSY, FUEL FE | 22570-1220A |
014. | [01] | 94901-81550 | WASHER, COPPER PLA | 96542-2150A |
016. | [01] | 09250-00334 | COUPLING ASSY | 22610-1280B |
016. | [01] | 09250-00681 | COUPLING ASSY | 22610-1480A |
017. | [02] | 94901-02480 | WASHER | 22847-1940A |
018. | [01] | 09031-00050 | VALVE ASSY, OVERFL | 22107-1190A |
018. | [01] | 09031-00130 | VALVE ASSY, OVERFL | 22107-1090A |
021. | [02] | 91418-06201 | BOLT, W/WASHER | 22815-1290A |
022. | [04] | 91518-06161 | BOLT, W/WASHER | 22815-1310A |
Include in #3:
19000-07860
as PUMP ASSY, INJECTI
19000-07860
Cross reference number
Part num | Firm num | Firm | Name |
19000-07860 | 22030-1670 | PUMP ASSY, INJECTI | |
22030-1670 | HINO | PUMP ASSY, INJECTI | |
S2203-01670 | HINO | PUMP ASSY, INJECTI |
Information:
Introduction
The problem that is identified below does not have a permanent solution. Until a permanent solution is known, use the solution that is listed below.Problem
A significant amount of HEUI pumps and injectors have been returned, but no cause of failure can be determined.Solution
Diagnostic procedures have been updated and have been incorporated into the following publications:
Special Instruction, REHS3819, "Procedure for Troubleshooting and Cleaning the Oil Rail System for the Hydraulic Electronic Unit Injector (HEUI)"
Troubleshooting, "Injection Actuation Pressure - Test"Note: These publications have been translated into Mandarin and Spanish.In addition, a new troubleshooting checklist is included with all service repair for HUEI pumps and HEUI injectors. The checklist is a summary of the diagnostic procedure steps to be confirmed before a suspect component is replaced. The checklist must be completed and returned with the suspect components in order to aid engineering to determine the cause of failure.Following the instructions step-by-step is critical in order to diagnose the failed component correctly. Do not skip steps in the procedures. Skipping steps in the procedure will lead to incorrect diagnosis of the problem.
The problem that is identified below does not have a permanent solution. Until a permanent solution is known, use the solution that is listed below.Problem
A significant amount of HEUI pumps and injectors have been returned, but no cause of failure can be determined.Solution
Diagnostic procedures have been updated and have been incorporated into the following publications:
Special Instruction, REHS3819, "Procedure for Troubleshooting and Cleaning the Oil Rail System for the Hydraulic Electronic Unit Injector (HEUI)"
Troubleshooting, "Injection Actuation Pressure - Test"Note: These publications have been translated into Mandarin and Spanish.In addition, a new troubleshooting checklist is included with all service repair for HUEI pumps and HEUI injectors. The checklist is a summary of the diagnostic procedure steps to be confirmed before a suspect component is replaced. The checklist must be completed and returned with the suspect components in order to aid engineering to determine the cause of failure.Following the instructions step-by-step is critical in order to diagnose the failed component correctly. Do not skip steps in the procedures. Skipping steps in the procedure will lead to incorrect diagnosis of the problem.