19000-07633 PUMP ASSY, INJECTI Denso Cross


 

Information pump assy, injecti

19000-07633 PUMP ASSY, INJECTI
Rating:
39
Buy PUMP ASSY, INJECTI 19000-07633 genuine, new aftermarket engine parts with delivery

Components :

001. PUMP ASSY, INJECTI 19000-07633
002. BODY ASSY, INJECTI 09010-05160
003. GOVERNOR ASSY, MEC 09130-00443
004. COVER ASSY, GOVERN 09145-00143
005. TIMER ASSY, AUTOMA 09180-01470
006. PUMP ASSY, FUEL FE 09210-01282
006. PUMP ASSY, FUEL FE 09210-01282
006. PUMP ASSY, FUEL FE 09210-01282

Scheme ###:

000. [01] 19000-07633 PUMP ASSY, INJECTI ME035739
003. [01] 09010-05161 BODY ASSY, INJECTI
004. [01] 09130-00443 GOVERNOR ASSY, MEC ME035925
005. [02] 91418-06201 BOLT, W/WASHER ME702041
006. [01] 09180-01470 TIMER ASSY, AUTOMA ME035924
007. [01] 09001-20270 NUT, TIMER ROUND
008. [01] 90801-40280 O-RING ME702918
009. [01] 94901-40070 WASHER, COUNTERSUN ME702919
010. [01] 94914-03690 O-RING ME736557
011. [01] 90458-05750 KEY, WOODRUFF ME702920
012. [01] 09031-00110 VALVE ASSY, OVERFL ME702087
013. [02] 09022-20070 WASHER, FUEL PIPE ME702217
015. [01] 09210-01282 PUMP ASSY, FUEL FE ME035919
016. [02] 94904-70620 BOLT, W/WASHER ME703359
018. [01] 09001-80381 COVER, CONTROL RAC ME728594
019. [01] 94901-81550 WASHER, COPPER PLA ME039681
020. [01] 09006-00200 COVER SUB-ASSY, TI
021. [04] 94905-02680 NUT, HEXAGON ME702046
023. [01] 09009-20130 BRACKET ME702270
025. [04] 94901-15020 WASHER, STEEL PLAT MH005068
028. [04] 94904-72690 BOLT, W/WASHER ME702045

Include in #3:

19000-07633 as PUMP ASSY, INJECTI

Cross reference number



Part num Firm num Firm Name
19000-07633  ME035739  PUMP ASSY, INJECTI




Information:

Battery
Every 250 hours check the electrolyte level of each cell and the general condition of the battery. Maintain the electrolyte level to the base of each vent well. The make-up water must be one of the following (in order of preference):1. Distilled water.2. Odorless, tasteless drinking water.3. Iron free water.
Never add acid or electrolyte.
Cleaning Battery
Mix a weak solution of baking soda and water. Apply the solution with a soft bristle brush. Be careful not to get cleaning solution into the battery.
CLEANING BATTERY TERMINALSThoroughly rinse the battery and battery tray with clean water. Apply grease to the battery cable clamps and terminals and to all threads.Testing The Electrolyte Solution
The general condition of a battery can be determined by measuring the specific gravity of the electrolyte solution and adjusting the reading to 80°F (27°C). If the electrolyte level is too low to allow taking a hydrometer reading, add make-up water to the correct level and then charge the battery 2 to 4 hours before taking a reading.1. Insert the hydrometer into a cell. Fill the hydrometer barrel while holding it vertically. The float must not drag on the wall of the barrel.2. Read the hydrometer: 1.265 - 100% charged1.225 - 75% charged1.190 - 50% charged1.155 - 25% charged1.120 - Discharged1.000 - Water3. Test each cell in the same manner.4. If there is more than .050 (50 gravity points) variation between the highest and lowest reading, the battery should be replaced.5. Adjust the readings to 80°F (27°C). a. For every 10°F (5.5°C) the electrolyte temperature is above 80°F (27°C), add .004 (4 gravity points) to the specific gravity readings.b. For every 10°F (5.5°C) the electrolyte temperature is below 80°F (27°C), subtract .004 (4 gravity points) from the specific gravity reading.The corrected reading is of most importance during cold weather when the hydrometer reading is always corrected to a lower specific gravity reading. A low reading signifies the battery has less available power to crank the engine and that booster batteries may be required.
TESTING ELECTROLYTE SOLUTIONInstalling Battery
1. Be sure the battery tray is clean and free of foreign objects.2. Be sure terminal posts and cable clamps are clean.3. Place the battery in the tray. Tighten the hold down clamps evenly until the battery is snug. Do not overtighten.4. Connect the "hot" terminal first. Be sure the top of the cable terminal is pushed down even with the top of the terminal post. Tighten the clamp firmly.
Always connect the "hot" terminal first to minimize arcing. Otherwise injury or damage could result.
5. Connect the "grounded" terminal last. Be sure the top of the cable terminal is pushed down even with the top of the terminal post. Tighten the clamp firmly.6. Apply a thin coating of grease over the cable clamps. terminals and hold down fasteners.Checking Charge Rate
1. After starting the engine, the ammeter indicator should register to the right of zero, but should never be "pegged".2. After the engine has been running, the indicator should be just to the right of zero. If the

Have questions with 19000-07633?





Group cross 19000-07633