19000-07500 PUMP ASSY, INJECTI Denso Cross


 

Information pump assy, injecti

Nozzle: 0935000800
19000-07500 PUMP ASSY, INJECTI
Rating:
3
Buy PUMP ASSY, INJECTI 19000-07500 genuine, new aftermarket engine parts with delivery

KIT List:

Body assy, injecti 1904400340
Governor assy, mec 1908900170
Pump assy, fuel fe 1922900060

Components :

001. PUMP ASSY, INJECTI 19000-07500
002. BODY ASSY, INJECTI 09010-05020
003. GOVERNOR ASSY, MEC 09080-07650
004. PUMP ASSY, FUEL FE 09210-00212
005. COUPLING ASSY 09250-00380

Scheme ###:

000. [01] 19000-07500 PUMP ASSY, INJECTI 22030-1450
006. [01] 09010-05020 BODY ASSY, INJECTI
007. [01] 09080-07650 GOVERNOR ASSY, MEC
008. [06] 91418-06161 BOLT, W/WASHER 22815-1380A
009. [01] 91518-08221 BOLT, W/WASHER 22815-1190A
011. [01] 09210-00212 PUMP ASSY, FUEL FE 22570-1200
012. [01] 09250-00380 COUPLING ASSY
013. [01] 09001-80080 COVER, CONTROL RAC 22114-1130A
014. [01] 09001-20010 NUT, TIMER ROUND 22353-1050A
015. [01] 90258-12001 WASHER, SPRING 22873-1310A
016. [01] 94913-00050 KEY, WOODRUFF 22891-1040A
017. [01] 09006-10011 COVER, PRIMING PUM 6 053 1552 60

Include in #3:

19000-07500 as PUMP ASSY, INJECTI

Cross reference number



Part num Firm num Firm Name
19000-07500  22030-1450  PUMP ASSY, INJECTI
22030-1450    HINO PUMP ASSY, INJECTI




Information:

Clean and Inspect
Before working inside the generator, make sure that the starter motor can not be activated by any automatic or manual signal.When the engine-generator is operating, voltages up to 600V are present in these areas near or on the regulator:1. The regulator terminal strip2. The excitation transformer terminal strip (self-excited generator only).Do not short these terminals to ground with any part of the body or any conductive material. Loss of life or injury could result from electrical shock or injury from molten metal.An electrical shock can be received from the regulator capacitor (C1) when the engine-generator is not in operation. To avoid possible injury, discharge the stored charge using an 100 ohm resistor across C1 terminals.
Electronic components in the regulator can be damaged during generator operation if contact is made between the part and ground.
If Moisture is allowed to remain in contact with an electrical winding, some of the moisture will eventually be absorbed. This will lower the resistance of the winding insulation. The insulation used on the windings of Caterpillar generators is moisture resistant, but constant exposure to moisture will gradually lower the insulation's resistance.Dirt can make the problem worse because it can hold the moisture in contact with the insulation. Salt (from sea air) can also make the problem much worse. This is because salt tends to absorb moisture from the air. When the salt and moisture combine, they make a good electrical conductor.Clean the voltage regulator and generator of dirt and debris. Use a brush to loosen accumulations of dirt and a vacuum system for removal. Use of compressed air is not recommended, because of moisture present in the form of condensate.Carbon tracking on insulators can be caused by dirt or loose connections. These carbon paths must be cleaned or the insulators replaced. Failure to correct a carbon tracking problem will eventually result in a short in the electrical circuit.Visually check for loose or broken wires and connections. Check the wires and connections on the regulator assembly. Check that all circuit boards are fully plugged in their sockets. Check all wires and connections in the generator. Make any necessary repairs to the wiring as required. Refer to the "Electric Set Generator Service Manual" for testing and adjusting or disassembly and assembly procedures.Space Heaters
The SR4 generator can operate in high humidity conditions without problems. However, problems can occur when the generator is idle and the surrounding air is warmer than the generator. Moisture can form on the windings and result in poor performance and even result in damage to the windings. Whenever the generator is not in use, insure that the space heaters are in operation.An external source of either 115 or 230 (200 v at 50 Hz) volts A.C. is required to operate the space heaters. Space Heater Connection to External Source H1, H2, H3, H4. Terminal Strip Terminals If 115 VAC source is available, connect both heaters in parallel across the source (L1-L2). If 230 VAC source is available, connect both heaters in