19000-07461 PUMP ASSY, INJECTI Denso Cross


 

Information pump assy, injecti

19000-07461 PUMP ASSY, INJECTI
Rating:
34
Buy PUMP ASSY, INJECTI 19000-07461 genuine, new aftermarket engine parts with delivery

Components :

001. PUMP ASSY, INJECTI 19000-07461
002. BODY ASSY, INJECTI 09010-04131
003. COVER, BEARING 09020-10430
004. GOVERNOR ASSY, MEC 09080-07481
005. TIMER ASSY, AUTOMA 09180-01271
005. TIMER ASSY, AUTOMA 09180-01271
006. PUMP ASSY, FUEL FE 09210-00942
007. COUPLING ASSY 09250-00334
007. COUPLING ASSY 09250-00334
008. COUPLING ASSY 09250-00681

Scheme ###:

000. [01] 19000-07461 PUMP ASSY, INJECTI 22030-1411
000. [01] 19000-07461 PUMP ASSY, INJECTI S2203-01411
003. [01] 09010-04132 BODY ASSY, INJECTI 22110-1700A
004. [01] 09080-07481 GOVERNOR ASSY, MEC 22330-1970A
005. [02] 94904-70620 BOLT, W/WASHER 22815-1620A
006. [01] 09001-80330 COVER, CONTROL RAC 22114-1140A
007. [01] 09180-01271 TIMER ASSY, AUTOMA 22510-1460A
008. [01] 09001-20230 NUT, TIMER ROUND 22825-1110A
009. [01] 90801-40280 O-RING 22817-1050A
010. [01] 94901-40070 WASHER, COUNTERSUN 22877-1190A
011. [01] 90458-05750 KEY, WOODRUFF 22891-1070A
012. [01] 09210-00942 PUMP ASSY, FUEL FE 22570-1220A
013. [01] 09006-10030 COVER, PRIMING PUM 22561-1040
014. [01] 94901-81550 WASHER, COPPER PLA 96542-2150A
016. [01] 09250-00334 COUPLING ASSY 22610-1280B
016. [01] 09250-00681 COUPLING ASSY 22610-1480A
017. [02] 94901-02480 WASHER 22847-1940A
018. [01] 09031-00130 VALVE ASSY, OVERFL 22107-1090A
021. [02] 91418-06201 BOLT, W/WASHER 22815-1290A
022. [04] 91518-06161 BOLT, W/WASHER 22815-1310A

Include in #3:

19000-07461 as PUMP ASSY, INJECTI
19000-07461

Cross reference number



Part num Firm num Firm Name
19000-07461  22030-1411  PUMP ASSY, INJECTI




Information:

Battery
Every 250 hours check the electrolyte level of each cell and the general condition of the battery. Maintain the electrolyte level to the base of each vent well. The make-up water must be one of the following (in order of preference):1. Distilled water.2. Odorless, tasteless drinking water.3. Iron free water.
Never add acid or electrolyte.
Cleaning Battery
Mix a weak solution of baking soda and water. Apply the solution with a soft bristle brush. Be careful not to get cleaning solution into the battery.
CLEANING BATTERY TERMINALSThoroughly rinse the battery and battery tray with clean water. Apply grease to the battery cable clamps and terminals and to all threads.Testing The Electrolyte Solution
The general condition of a battery can be determined by measuring the specific gravity of the electrolyte solution and adjusting the reading to 80°F (27°C). If the electrolyte level is too low to allow taking a hydrometer reading, add make-up water to the correct level and then charge the battery 2 to 4 hours before taking a reading.1. Insert the hydrometer into a cell. Fill the hydrometer barrel while holding it vertically. The float must not drag on the wall of the barrel.2. Read the hydrometer: 1.265 - 100% charged1.225 - 75% charged1.190 - 50% charged1.155 - 25% charged1.120 - Discharged1.000 - Water3. Test each cell in the same manner.4. If there is more than .050 (50 gravity points) variation between the highest and lowest reading, the battery should be replaced.5. Adjust the readings to 80°F (27°C). a. For every 10°F (5.5°C) the electrolyte temperature is above 80°F (27°C), add .004 (4 gravity points) to the specific gravity readings.b. For every 10°F (5.5°C) the electrolyte temperature is below 80°F (27°C), subtract .004 (4 gravity points) from the specific gravity reading.The corrected reading is of most importance during cold weather when the hydrometer reading is always corrected to a lower specific gravity reading. A low reading signifies the battery has less available power to crank the engine and that booster batteries may be required.
TESTING ELECTROLYTE SOLUTIONInstalling Battery
1. Be sure the battery tray is clean and free of foreign objects.2. Be sure terminal posts and cable clamps are clean.3. Place the battery in the tray. Tighten the hold down clamps evenly until the battery is snug. Do not overtighten.4. Connect the "hot" terminal first. Be sure the top of the cable terminal is pushed down even with the top of the terminal post. Tighten the clamp firmly.
Always connect the "hot" terminal first to minimize arcing. Otherwise injury or damage could result.
5. Connect the "grounded" terminal last. Be sure the top of the cable terminal is pushed down even with the top of the terminal post. Tighten the clamp firmly.6. Apply a thin coating of grease over the cable clamps. terminals and hold down fasteners.Checking Charge Rate
1. After starting the engine, the ammeter indicator should register to the right of zero, but should never be "pegged".2. After the engine has been running, the indicator should be just to the right of zero. If the

Have questions with 19000-07461?





Group cross 19000-07461