09621-00892 COVER SUB-ASSY, TI Denso Cross


 

Information cover sub-assy, ti

09621-00892 COVER SUB-ASSY, TI
Rating:
66
Buy COVER SUB-ASSY, TI 09621-00892 genuine, new aftermarket engine parts with delivery

Scheme ###:

000. [01] 09621-00892 COVER SUB-ASSY, TI 22790-17590
001. [01] 09621-80092 COVER, TIMER
002. [01] 09648-50170 THERMO-ELEMENT SUB
003. [01] 09604-90280 O-RING
004. [01] 90567-28001 RING, HOLE SNAP
005. [01] 09007-80121 COVER
006. [01] 09645-10690 SHAFT SUB-ASSY, AD
007. [01] 09627-30140 WASHER, GOVERNOR T 22378-64010
008. [01] 94914-02910 O-RING 90099-14048
008. [01] 09604-90300 O-RING 22193-54770
009. [01] 94919-25581 COLLAR, STEEL
010. [01] 09644-40790 SPRING, RETURN
011. [01] 09644-40070 SPRING, RETURN
012. [01] 09644-50122 GUIDE, RETURN SPRI
013. [01] 09643-63511 LEVER, ADJUSTING
014. [01] 09643-63491 LEVER, ADJUSTING
015. [01] 94905-63320 NUT
015. [01] 92156-08081 NUT, FLANGE
016. [02] 91160-05041 NUT, HEXAGON 94115-40500
017. [02] 09266-40100 SCREW, LEVER STOP

Cross reference number



Part num Firm num Firm Name
09621-00892  22790-1759  COVER SUB-ASSY, TI




Information:

After Storage
Test the main stator windings with a megohmmeter in the following situations: 1. Before initial startup of generator set.2. Every 3 months* if generator is operating in a humid environment.3. If generator has not been run under load for 3 months* or more.*This is a guideline only. It may be necessary to megger more frequently if environment is extremely humid, salty or if the last megger test was close to 1 megohm.The megohmmeter test is described in Service Manuals SENR2180 or SENR7968. A reading of 1 meghom or less indicates that the winding has absorbed too much moisture.To Remove Moisture
To remove moisture caused by high humidity, use one of the following methods to make the generator dry:1. Energize space heaters in generator if so equipped.2. Put the generator in an oven at a temperature of not more than 85°C (185°F) for four hours.
If an oven is used for drying, use a forced air type rather than a radiant type. Radiant ovens can cause localized overheating.
3. Space heaters of the same type used in marine applications, can be installed on generators. (See the Parts Book.) These heaters heat the windings to remove moisture and should be connected at all times in high humidity conditions whenever the generator is not running.4. Use a canvas enclosure around the generator and heating lamps to increase the temperature. Make an opening in the top for release of moisture.5. Send a low voltage current through the windings to increase the temperature of the windings. Do not exceed 85°C (185°F).If the megohmmeter test reads under 1 megohm after the drying or if it goes below 1 megohm shortly after drying, contact your Caterpillar dealer. The insulation has deteriorated and should be reconditioned.