Information pump assy, injecti
PUMP ASSY, INJECTI
ZC
- NOZZLE & NOZZLE HOLDER ASSENBLY : 093500-5170(-2004.04)
- ,093500-7520(2004.05-)
Nozzle:
0935005170

Rating:
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
IMIFAFTAbT 094500-8280 Fuel Injection Pump 131017980 131017981 Fits For Perkins 402D-05 Engine
IMIFAFTAbT Part Name:Fuel Injection Pump 094500-8280 131017980 131017981 || Part Number:094500-8280 131017980 131017981 || APPlication: Compatible For Perkins 402D-05 Engine || If you are not sure if the product is suitable please leave us a message and send us your original || product picture and part number and we will send the correct part after confirmation
IMIFAFTAbT Part Name:Fuel Injection Pump 094500-8280 131017980 131017981 || Part Number:094500-8280 131017980 131017981 || APPlication: Compatible For Perkins 402D-05 Engine || If you are not sure if the product is suitable please leave us a message and send us your original || product picture and part number and we will send the correct part after confirmation
Fuel Injection Pump 094500-8280 131017980 131017981 Fits for Perkins 402D-05 Engine
XYohykai ◆Part Name◆:Fuel Injection pump || ◆Part Number◆:094500-8280 131017980 131017981 || ◆Application◆:Fits for Perkins 402D-05 Engine || ◆Notice◆-Application information provided is for reference only. Please confirm the part number and compare old parts before purchase. If you have any question,pls feel free to ask us. || ◆Worth Choice◆-This product has stable performance high reliability easy installation and fast response.
XYohykai ◆Part Name◆:Fuel Injection pump || ◆Part Number◆:094500-8280 131017980 131017981 || ◆Application◆:Fits for Perkins 402D-05 Engine || ◆Notice◆-Application information provided is for reference only. Please confirm the part number and compare old parts before purchase. If you have any question,pls feel free to ask us. || ◆Worth Choice◆-This product has stable performance high reliability easy installation and fast response.
DoraKvi Fuel Injection Pump 094500-8280 131017980 131017981 Compatible with Perkins 402D-05 Engine
DoraKvi 🌟 Part Name :Fuel Injection Pump || 🌟 Part Number :094500-8280 0945008280 131017980 131017981 || 🌟 Application : Compatible with Perkins 402D-05 Engine || ✅ Accurate ✅- In Order To Avoid Unnecessary Returnplease. Please follow the old part number and machine model to find the right product, if you are not sure, please contact us, we are more than happy to provide services. || 💠 Reliable performance 💠- our products have been carefully designed and tested, with high reliability and stability, can maintain good working condition for a long time.
DoraKvi 🌟 Part Name :Fuel Injection Pump || 🌟 Part Number :094500-8280 0945008280 131017980 131017981 || 🌟 Application : Compatible with Perkins 402D-05 Engine || ✅ Accurate ✅- In Order To Avoid Unnecessary Returnplease. Please follow the old part number and machine model to find the right product, if you are not sure, please contact us, we are more than happy to provide services. || 💠 Reliable performance 💠- our products have been carefully designed and tested, with high reliability and stability, can maintain good working condition for a long time.
Components :
001. | PUMP ASSY, INJECTI | 09450-08280 |
001. | PUMP ASSY, INJECTI | 09450-08280 |
Scheme ###:
000. | [01] | 09450-08280 | PUMP ASSY, INJECTI | 131017980 |
000. | [01] | 09450-08280 | PUMP ASSY, INJECTI | 131017981 |
001. | [01] | 09011-06080 | HOUSING SUB-ASSY, | |
002. | [02] | 09013-00390 | HOLDER SUB-ASSY, D | 131196210 |
003. | [02] | 09013-60530 | SPRING, DELIVERY V | 131176430 |
004. | [02] | 09013-70130 | GASKET, DELIVERY V | 131186050 |
005. | [02] | 09014-02790 | VALVE SUB-ASSY, IN | |
006. | [02] | 09015-06590 | ELEMENT SUB-ASSY, | 131116670 |
006. | [02] | 09015-06720 | ELEMENT SUB-ASSY, | |
007. | [02] | 09016-00140 | SLEEVE SUB-ASSY, C | 131296950 |
008. | [02] | 09016-30140 | SEAT, SPRING, UPR | 131296620 |
009. | [02] | 09016-40220 | SPRING, PUMP PLUNG | 131176440 |
010. | [02] | 09016-50170 | SEAT, SPRING, LWR | 131296621 |
011. | [02] | 09017-00220 | TAPPET SUB-ASSY,IN | 131256120 |
012. | [01] | 09021-00550 | RACK ASSY, CONTROL | 131296661 |
014. | [01] | 09024-50240 | SCREW, HOLLOW | 131236190 |
016. | [02] | 09025-10010 | WASHER, INJECTION | 131426180 |
017. | [02] | 09018-30090 | PIN, INJECTION PUM | 131296651 |
018. | [02] | 09023-00070 | PLATE SET, VALVE H | 131296662 |
019. | [01] | 09069-11070 | BRACKET, STOP WIRE | 131296664 |
020. | [02] | 94900-20500 | SCREW, COUNTERSUNK | 131136320 |
021. | [02] | 94900-75390 | SCREW, W/WASHER | 131136330 |
022. | [02] | 90801-10130 | O-RING | 131226170 |
022. | [02] | 09013-90400 | O-RING | |
023. | [01] | 94918-10430 | NIPPLE, SWIVELING | 131246130 |
024. | [2C] | 09031-10400 | PLATE, TAPPET ADJU | 131296630 |
024. | [2C] | 09031-10410 | PLATE, TAPPET ADJU | 131296631 |
024. | [2C] | 09031-10420 | PLATE, TAPPET ADJU | 131296632 |
024. | [2C] | 09031-10430 | PLATE, TAPPET ADJU | 131296633 |
024. | [2C] | 09031-10440 | PLATE, TAPPET ADJU | 131296634 |
024. | [2C] | 09031-10390 | PLATE, TAPPET ADJU | 131296629 |
024. | [2C] | 09031-10380 | PLATE, TAPPET ADJU | 131296628 |
024. | [2C] | 09031-10370 | PLATE, TAPPET ADJU | 131296627 |
024. | [2C] | 09031-10360 | PLATE, TAPPET ADJU | 131296626 |
024. | [2C] | 09031-10350 | PLATE, TAPPET ADJU | 131296625 |
024. | [2C] | 09031-10340 | PLATE, TAPPET ADJU | 131296624 |
024. | [2C] | 09031-10330 | PLATE, TAPPET ADJU | 131296623 |
024. | [2C] | 09031-10320 | PLATE, TAPPET ADJU | 131296622 |
024. | [2C] | 09031-10450 | PLATE, TAPPET ADJU | 131296635 |
Include in #3:
09450-08280
as PUMP ASSY, INJECTI
09450-08280
Cross reference number
Part num | Firm num | Firm | Name |
09450-08280 | 131017980 | PUMP ASSY, INJECTI | |
131017981 | ISHIKAWAJIMA | PUMP ASSY, INJECTI | |
131017980 | ISHIKAWAJIMA | PUMP ASSY, INJECTI |
Information:
Automatic Start-Stop
An automatic start-stop system is used when an engine must start when a specific condition occurs with no one in attendance. The engine will start, increase speed, pick-up the load, operate the load until a second condition occurs, remove the load, cool and stop. The following conditions must exist for the engine to start unattended:Either the ambient (engine room) temperature must be at least 70°F (20°C); or, the engine jacket water temperature must be at least 90°F (32°C). One or two 3 kw jacket water heaters can maintain this temperature.Protection Devices
The Caterpillar generator mounted control panel is equipped with protection devices to protect the engine while cranking.Batteries
Lights or buttons may indicate if a fault has occurred in the battery charging system causing the battery to be either undercharged or overcharged.Overcranking
A timer allows the engine to crank either once for 30 seconds, or to crank through 5 ten-second cranking cycles (depending upon the device used) while unattended. If the engine does not start before the time elapsed, the fuel system will be shutoff and a light will indicate a starting failure. Engine Operation
Prealarm systems provide an audible and/or a visual indication for low oil pressure, high water temperature, low fuel supply or low jacket water temperature before the condition becomes critical. These alarms are self resetting when the condition is corrected. The engine may also be equipped with shutdown devices. If low oil pressure, high jacket water temperature or an engine overspeed condition occurs, the engine will be shutdown and a corresponding button or light will indicate the cause of the shutdown. These devices must be reset after repairs have been made and before starting. See the topic, EMERGENCY SHUTOFF DEVICES AND ALARMS.Generator set control panels should be equipped with an ammeter, a frequency meter and a voltmeter. Depending upon the type of operation, the panel may also be equipped with other meters and lights. Know these instruments and their normal readings. They will indicate how the generator set is performing.Shutting Down
A timer allows the transfer switch to transfer the load to another source and to continue engine running for up to 2 minutes for cooling purposes before stopping.Engine Exerciser
At preset times, the exerciser will start, run and stop the engine in order to ensure both proper lubrication of all engine parts and proper equipment operation if and when the standby unit is needed.Become familiar with all instructions included with the equipment.Woodward Governors
Woodward Governors are usually electrically operated from a control panel.Generator Set Control Panel
The generator set control panel is located on top of the generator and is equipped with the following controls and gauges:Panel lights (1) are controlled by an ON/OFF switch (7). An ammeter (2), frequency meter (3) and a voltmeter (4) show the output of the generator. Two gauges (5 and 6) show engine oil pressure and water temperature respectively. The ammeter selector switch (12) gives the operator a choice of which phase (T1, T2 or T3) of the generator output the ammeter (2) will
An automatic start-stop system is used when an engine must start when a specific condition occurs with no one in attendance. The engine will start, increase speed, pick-up the load, operate the load until a second condition occurs, remove the load, cool and stop. The following conditions must exist for the engine to start unattended:Either the ambient (engine room) temperature must be at least 70°F (20°C); or, the engine jacket water temperature must be at least 90°F (32°C). One or two 3 kw jacket water heaters can maintain this temperature.Protection Devices
The Caterpillar generator mounted control panel is equipped with protection devices to protect the engine while cranking.Batteries
Lights or buttons may indicate if a fault has occurred in the battery charging system causing the battery to be either undercharged or overcharged.Overcranking
A timer allows the engine to crank either once for 30 seconds, or to crank through 5 ten-second cranking cycles (depending upon the device used) while unattended. If the engine does not start before the time elapsed, the fuel system will be shutoff and a light will indicate a starting failure. Engine Operation
Prealarm systems provide an audible and/or a visual indication for low oil pressure, high water temperature, low fuel supply or low jacket water temperature before the condition becomes critical. These alarms are self resetting when the condition is corrected. The engine may also be equipped with shutdown devices. If low oil pressure, high jacket water temperature or an engine overspeed condition occurs, the engine will be shutdown and a corresponding button or light will indicate the cause of the shutdown. These devices must be reset after repairs have been made and before starting. See the topic, EMERGENCY SHUTOFF DEVICES AND ALARMS.Generator set control panels should be equipped with an ammeter, a frequency meter and a voltmeter. Depending upon the type of operation, the panel may also be equipped with other meters and lights. Know these instruments and their normal readings. They will indicate how the generator set is performing.Shutting Down
A timer allows the transfer switch to transfer the load to another source and to continue engine running for up to 2 minutes for cooling purposes before stopping.Engine Exerciser
At preset times, the exerciser will start, run and stop the engine in order to ensure both proper lubrication of all engine parts and proper equipment operation if and when the standby unit is needed.Become familiar with all instructions included with the equipment.Woodward Governors
Woodward Governors are usually electrically operated from a control panel.Generator Set Control Panel
The generator set control panel is located on top of the generator and is equipped with the following controls and gauges:Panel lights (1) are controlled by an ON/OFF switch (7). An ammeter (2), frequency meter (3) and a voltmeter (4) show the output of the generator. Two gauges (5 and 6) show engine oil pressure and water temperature respectively. The ammeter selector switch (12) gives the operator a choice of which phase (T1, T2 or T3) of the generator output the ammeter (2) will