09450-00100 PUMP ASSY, INJECTI Denso Cross


 

Information pump assy, injecti

PUMP ASSY, INJECTI EA
  • OLD P/N:090000-1982
  • NOZZLE AND H :093500-0650
Nozzle: 0935000650
09450-00100 PUMP ASSY, INJECTI
Rating:
36
Buy PUMP ASSY, INJECTI 09450-00100 genuine, new aftermarket engine parts with delivery

Components :

001. PUMP ASSY, INJECTI 09450-00100

Scheme ###:

000. [01] 09450-00100 PUMP ASSY, INJECTI P721-10182
005. [01] 09013-10010 HOLDER, DELIVERY V ME022081
006. [01] 09010-90531 HOUSING SUB-ASSY, P720-11390
007. [01] 09013-60080 SPRING, DELIVERY V MM500331
008. [01] 09013-70010 GASKET, DELIVERY V ME022084
009. [01] 09014-00170 VALVE SUB-ASSY, IN P720-14930
010. [01] 09015-00651 ELEMENT SUB-ASSY, P720-13000
011. [01] 09016-10120 SLEEVE, PLUNGER CO P761-14051
012. [01] 09016-30040 SEAT, SPRING, UPR MM500356
013. [01] 09016-40110 SPRING, PUMP PLUNG MM500359
014. [01] 09016-50030 SEAT, SPRING, LWR MM500361
015. [1C] 09031-10160 PLATE, TAPPET ADJU MM500314
015. [1C] 09031-10140 PLATE, TAPPET ADJU MM500312
015. [1C] 09031-10130 PLATE, TAPPET ADJU MM500311
015. [1C] 09031-10120 PLATE, TAPPET ADJU MM500310
015. [1C] 09031-10090 PLATE, TAPPET ADJU MM500307
015. [1C] 09031-10080 PLATE, TAPPET ADJU MM500306
015. [1C] 09031-10070 PLATE, TAPPET ADJU MM500305
015. [1C] 09031-10060 PLATE, TAPPET ADJU MM500304
015. [1C] 09031-10050 PLATE, TAPPET ADJU MM500303
015. [1C] 09031-10040 PLATE, TAPPET ADJU MM500302
015. [1C] 09031-10030 PLATE, TAPPET ADJU MM500301
015. [1C] 09031-10020 PLATE, TAPPET ADJU MM500300
015. [1C] 09031-10010 PLATE, TAPPET ADJU ME702559
016. [01] 09017-00102 TAPPET SUB-ASSY,IN P760-1431
017. [01] 09018-30010 PIN, INJECTION PUM MM500368
018. [01] 09018-40060 RING, CLAMP MM500371
019. [01] 09021-00121 RACK ASSY, CONTROL MM500374
020. [01] 09022-20080 WASHER, FUEL PIPE ME702235
020. [01] 94901-81020 WASHER, COPPER PLA ME022309
021. [01] 09024-40180 SCREW, AIR BLEEDER MM501152
022. [01] 09024-50210 SCREW, HOLLOW MM501320
023. [01] 09022-30010 PLATE, PUSH MM500401
024. [01] 09055-40040 SPRING, DIAPHRAGM MM500405
025. [01] 90400-16101 PIN, SPLIT MM500431
026. [01] 09007-80013 COVER MM500365
027. [1C] 09021-90700 STOPPER MM514094
027. [1C] 09021-90400 STOPPER MM514059
027. [1C] 09021-90390 STOPPER MM514082
027. [1C] 09021-90370 STOPPER MM514085
027. [1C] 09021-90360 STOPPER MM514084
027. [1C] 09021-90330 STOPPER MM514057
027. [1C] 09021-90320 STOPPER MM514056
027. [1C] 09021-90051 STOPPER MM514083
027. [1C] 09021-90710 STOPPER MM514095

Include in #3:

09450-00100 as PUMP ASSY, INJECTI

Cross reference number



Part num Firm num Firm Name
09450-00100  P721-10182  PUMP ASSY, INJECTI
P721-10182    MITSUBISHI PUMP ASSY, INJECTI




Information:


AIR CLEANER SERVICE INDICATORExcessive engine exhaust smoke and/or loss of power may indicate the need for servicing the air cleaner. Never service the air cleaner while the engine is running.Single Stage Air Cleaner
Changing Filter Element
Service the air cleaner with the engine stopped.
1. Remove the air cleaner cover and element. 2. Cover the air inlet opening to prevent foreign objects from entering the engine.3. Clean the inside of the air cleaner cover and the air cleaner body. 4. Inspect the replacement element for damage and cleanliness. Have a replacement element on hand to install and use while cleaning the dirty element. This will save you down time.5. Remove the covering from the air inlet opening.6. Install the element.
Install the air cleaner element as shown in the illustration. Note the arrows indicating air flow on the side of the element, and the position of the gasket.
7. Install the air cleaner cover.8. Reset the service indicator button by pushing on the reset button.9. Clean the used air cleaner element. See the instructions for cleaning. Cleaning Filter Elements
Cleaning Elements With Air
1. Use clean, dry air-30 PSI (2 kg/cm2) maximum. Hold the nozzle at least one inch from the element and at a slight angle.
When using pressure air, wear safety glasses and protective clothing. Use no more than 30 PSI (2 kg/cm2) pressure.
2. Direct the air stream along the complete length of each pleat on the CLEANEST side of the element. (This will loosen the dirt from the dirtier side.)3. Blow the loosened dirt from the DIRTY side.4. Direct the air from the CLEAN side through to the DIRTY side to remove dirt blown into the pleating.Cleaning Elements With Water
1. Use clean water at no more than 40 psi (3 kg/cm2). Do not use a nozzle.2. Direct the water along the complete length of each pleat on the CLEAN side of the element.3. Direct water along the complete length of each pleat on the DIRTY side of the element.4. Rinse the CLEAN side of the element.5. Allow the cleaned element to dry thoroughly.Cleaning Elements With Detergent
1. Wash both sides of the element in a solution of warm water and non-sudsing detergent.2. Rinse the CLEANEST side of the element with clean water 40 psi (3 kg/cm2) maximum along with the complete length of each pleat.3. Rinse the opposite side of the element along the complete length of each pleat.4. Rinse the first side again to remove all loosened dirt.5. Allow the cleaned element to dry thoroughly.Inspecting Cleaned Elements
Place a lighted electric bulb behind the cleaned, dried filter element. Carefully check each pleat for holes or tears. If just one small hole or tear is found, discard that element and install a new element.Storing Cleaned Elements
1. Wrap usable elements in heavy paper.2. Store the wrapped element in a dry, clean place.Dust Collector Cap
Servicing Dust Collector Cap
1. Remove the cap from the air cleaner inlet.2. Clean the bottom grill using pressure air (maximum 30 psi-2.0 kg/cm2), or low sudsing detergent and water. Install the cap.
Protective eye

Have questions with 09450-00100?





Group cross 09450-00100

Back to top