09350-04710 HOLDER & NOZZLE SE Denso Cross


 

Information holder & nozzle se

09350-04710 HOLDER & NOZZLE SE
Rating:
5
Buy HOLDER & NOZZLE SE 09350-04710 genuine, new aftermarket engine parts with delivery

Components :

001. HOLDER & NOZZLE SE 09350-04710

Scheme ###:

000. [01] 09350-04710 HOLDER & NOZZLE SE 30A6100600
001. [01] 09310-04710 HOLDER ASSY, NOZZL 30A6100900
001-001. [01] 09311-04710 BODY SUB-ASSY, NOZ
001-002. [01] 09312-10480 PIN, NOZZLE HOLDER MM514343
001-003. [01] 09312-70410 SPRING, NOZZLE HOL MM514344
001-004. [01] 09316-41020 NUT, NOZZLE RETAIN MM501788
001-005. [1C] 09317-52430 WASHER MM514357
001-005. [1C] 09317-52420 WASHER MM514356
001-005. [1C] 09317-52410 WASHER MM514355
001-005. [1C] 09317-52400 WASHER MM514354
001-005. [1C] 09317-52390 WASHER MM514353
001-005. [1C] 09317-52380 WASHER MM514352
001-005. [1C] 09317-52370 WASHER MM514351
001-005. [1C] 09317-52440 WASHER
001-005. [1C] 09317-52450 WASHER MM514359
001-005. [1C] 09317-52460 WASHER MM514360
001-005. [1C] 09317-52470 WASHER MM514361
001-005. [1C] 09317-52480 WASHER MM514362
001-005. [1C] 09317-52490 WASHER MM514363
001-005. [1C] 09317-52500 WASHER MM514364
001-005. [1C] 09317-52510 WASHER MM514365
001-005. [1C] 09317-52520 WASHER MM514366
001-005. [1C] 09317-52530 WASHER
001-005. [1C] 09317-52360 WASHER MM514350
001-005. [1C] 09317-52350 WASHER MM514349
001-005. [1C] 09317-52180 WASHER
001-005. [1C] 09317-52190 WASHER
001-005. [1C] 09317-52200 WASHER
001-005. [1C] 09317-52210 WASHER
001-005. [1C] 09317-52220 WASHER
001-005. [1C] 09317-52230 WASHER
001-005. [1C] 09317-52240 WASHER
001-005. [1C] 09317-52250 WASHER
001-005. [1C] 09317-52260 WASHER
001-005. [1C] 09317-52270 WASHER
001-005. [1C] 09317-52340 WASHER
001-005. [1C] 09317-52330 WASHER
001-005. [1C] 09317-52320 WASHER
001-005. [1C] 09317-52310 WASHER
001-005. [1C] 09317-52300 WASHER MM501781
001-005. [1C] 09317-52290 WASHER
001-005. [1C] 09317-52280 WASHER
001-006. [01] 09322-10150 PACKING, TIP
001-007. [02] 94908-23160 PIN, STRAIGHT MM501790
002. [01] 09340-05830 NOZZLE ASSY 30A6100800

Include in #3:

09350-04710 as HOLDER & NOZZLE SE

Include as Nozzle:

0945005690 as Nozzle

Cross reference number



Part num Firm num Firm Name
09350-04710  30A6100600  HOLDER & NOZZLE SE
30A6100600    MITSUBISHI HOLDER & NOZZLE SE




Information:

some applications. Use the following procedure to enable password protection. Changing the password protection can be done with the PC software for the CCM . The password protection can also be changed by using a host device to write the IIDs.Disabling PasswordsTo disable the passwords, the AA12 and AA8A PIDs must be used.Note: Refer to the Operation and Maintenance Manual, "Parameter Identifiers for General Usage".
Use IID 34 with a unit number of 61. Write to PID AA8A with the level 3 password. This will set the security level in the CCM to level 3. The message will be 5000340C0061AA8Ab1b2b3b4b5b6b7b8cs. The example above shows that b1 through b8 are the ASCII characters of the password. If the password is all spaces, simply end the message after PID AA8A. Do not include any of the data bytes. The CCM will automatically add spaces when a character is not present.
Use IID 34 with a unit number of 61. Write PID AA 12 with bit 3 set. This will disable the password protection. The message will be 500034050061AA1204cs. This message will disable the passwords. Baud rate changes will be enabled. The CCM will be set for a direct connection. Bits 1 and 2 should be set to 1 if the last two items need to be set the other way. Note: When the passwords are disabled, all three passwords are set to all blanks (spaces).Enabling PasswordsThe AA12 and the F012 PIDs must be used in order to enable the password protection.Note: Refer to the Operation and Maintenance Manual, "Parameter Identifiers for General Usage".
Use IID 34 with a unit number of 61. Write to PID AA12 to clear bit 3. The message format will be 500034050061AA1200cs. This message will enable the following items: passwords, change of baud rate and set the CCM for direct connect. Bits 1 and 2 should be set to 1 if the last two items need to be set the other way.
In order to enable the changes, the power to the CCM must be cycled or the security level must be written to zero. The security level is written to zero by using IID 34. The message will be 500034050061F01200cs. Note: When the passwords were disabled, each character was set to a blank or space. Set the level 3 password on the CCM to something other than spaces.

Have questions with 09350-04710?





Group cross 09350-04710

Back to top