09300-02122 PUMP ASSY, INJECTI Denso Cross


 

Information pump assy, injecti

09300-02122 PUMP ASSY, INJECTI
Rating:
78
Buy PUMP ASSY, INJECTI 09300-02122 genuine, new aftermarket engine parts with delivery

Components :

001. PUMP ASSY, INJECTI 09300-02122
001. PUMP ASSY, INJECTI 09300-02122
002. BODY ASSY, INJECTI 09010-05081
003. GOVERNOR ASSY, MEC 09130-01300
003. GOVERNOR ASSY, MEC 09130-01300
004. COVER ASSY, GOVERN 09145-00384
005. TIMER ASSY, AUTOMA 09180-02180
006. PUMP ASSY, FUEL FE 09210-01551

Scheme ###:

000. [01] 09300-02121 PUMP ASSY, INJECTI ME016354
000. [01] 09300-02122 PUMP ASSY, INJECTI ME016354
003. [01] 09010-05081 BODY ASSY, INJECTI ME016132
004. [01] 09130-01300 GOVERNOR ASSY, MEC ME703383
005. [01] 09210-01551 PUMP ASSY, FUEL FE ME703037
006. [01] 09180-02180 TIMER ASSY, AUTOMA ME703384
007. [01] 09006-00171 COVER SUB-ASSY, TI ME016071
007. [01] 09006-00320 COVER SUB-ASSY, TI ME703649
008. [01] 94914-02840 O-RING MH035502
009. [04] 94901-15020 WASHER, STEEL PLAT MH005068
012. [01] 94913-00210 KEY, WOODRUFF ME702047
013. [01] 94901-40210 WASHER, COUNTERSUN ME702043
014. [01] 09001-20220 NUT, TIMER ROUND ME702033
015. [01] 09001-80090 COVER, CONTROL RAC ME702251
017. [01] 94904-72990 BOLT, W/WASHER ME703038
018. [03] 94904-72690 BOLT, W/WASHER ME702045
019. [02] 91418-06201 BOLT, W/WASHER ME702041
020. [01] 94904-04300 BOLT, HEXAGON ME702044
023. [01] 09028-50021 CAP ME035845

Include in #3:

09300-02122 as PUMP ASSY, INJECTI

Cross reference number



Part num Firm num Firm Name
09300-02122  ME016354  PUMP ASSY, INJECTI




Information:


Illustration 1 g00565418
4W-8471 Time Delay Relay
Use a 6V-7070 Digital Multimeter, a stopwatch, and a battery (8 volts to 40 volts) for this test.
Connect the positive lead of the voltage source to terminal (TD-4) of the time delay relay. Connect the negative lead to terminal (TD-3). If the test is done on an engine, the start/stop switch must be in the STOP position in order to power terminal (TD-6). All connections must be maintained until the tests are completed.
Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 1
Terminals     Relay Position    
5-6     Closed    
6-7     Open    
Connect the positive lead of the voltage source to terminal (TD-1). If the time delay relay is tested on the engine do not leave the voltage source hooked to terminal (TD-1) for more than 60 seconds. The fuel shutoff solenoid will be energized. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 2
Terminals     Relay Position    
5-6     Open    
6-7     Closed    
Remove the positive lead of the voltage source from terminal (TD-1). Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 3
Terminals     Delay Time of Relay Position    
0 to 60 seconds 80 seconds or more    
5-6     Open     Closed    
6-7     Closed     Open    Note: If a jumper is normally installed across terminals (TD-2) and (TD-3), the jumper must be removed before performing Step 5.
Connect the positive lead of the voltage source to terminal (TD-2). If the time delay relay is tested on the engine, do not leave the voltage source on terminal (TD-2) for more than 60 seconds. The fuel shutoff solenoid will be energized. Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 4
Terminals     Delay Time of Relay Position    
0 to 8 seconds 10 seconds or more    
5-6     Closed     Open    
6-7     Open     Closed    
Remove the positive lead of the voltage source from terminal (TD-1). Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 5
Terminals     Delay Time of Relay Position    
0 to 60 seconds 80 seconds or more    
5-6     Open     Closed    
6-7     Closed     Open    
Remove the voltage source from terminal (TD-4). Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 6
Terminals     Relay Position    
5-6     Closed    
6-7     Open    