09210-00342 PUMP ASSY, FUEL FE Denso Cross


 

Information pump assy, fuel fe

09210-00342 PUMP ASSY, FUEL FE
Rating:
23
Buy PUMP ASSY, FUEL FE 09210-00342 genuine, new aftermarket engine parts with delivery

Scheme ###:

000. [01] 09210-00342 PUMP ASSY, FUEL FE 6 065 1501 01
003. [01] 09212-00033 HOUSING SUB-ASSY, 6 056 1327 40
003-001. [01] 09216-80150 ROD, FEED PUMP PUS 22565-1250A
003-001. [1C] 09216-80070 ROD, FEED PUMP PUS 22565-1190A
003-001. [1C] 09216-80060 ROD, FEED PUMP PUS 22565-1180A
003-001. [1C] 09216-80050 ROD, FEED PUMP PUS 22565-1170A
003-001. [1C] 09216-80040 ROD, FEED PUMP PUS 22565-1160A
003-001. [1C] 09216-80030 ROD, FEED PUMP PUS 22565-1150A
003-001. [1C] 09216-80010 ROD, FEED PUMP PUS 22565-1140A
003-002. [01] 94915-00970 SEAL, OIL 22827-1090A
003-002. [01] 94915-02700 SEAL, OIL 22827-1700A
005. [02] 09212-10011 VALVE, FEED PUMP C 22563-1041A
006. [02] 09212-40010 SPRING, FEED PUMP 22562-1020A
007. [02] 09212-50010 GASKET, CHECK VALV 22847-1680A
008. [01] 09212-60010 PLUG, FEED PUMP CH 22845-1350A
009. [01] 09213-00220 PUMP SUB-ASSY, PRI 22509-1160A
011. [01] 09217-10011 PISTON, FEED PUMP 22566-1200A
013. [01] 09217-60010 ROLLER, FEED PUMP 22569-1110A
014. [01] 09217-80010 PIN, FEED PUMP TAP 22571-1100A
015. [02] 09217-90050 BLOCK, FEED PUMP T 22572-1080A
016. [01] 94907-20940 RING, SNAP 22887-1160A
018. [01] 94901-81240 WASHER, COPPER PLA 22847-1690A
019. [01] 09218-40021 PLUG, FEED PUMP PI 22845-1360A
020. [01] 09222-30070 SCREW, FUEL PIPE H 22835-1370A
021. [01] 09222-00040 FILTER, FEED PUMP 22574-1040A
022. [01] 94918-00310 SCREW, HOLLOW S2283-51310-A
023. [04] 94901-02490 WASHER 22877-1100A
024. [01] 09217-40030 TAPPET, FEED PUMP 22568-1180A
025. [01] 09218-20020 SPRING, FEED PUMP 22567-1070A

Cross reference number



Part num Firm num Firm Name
09210-00342  6 065 1501  PUMP ASSY, FUEL FE




Information:

Disassembly and Inspection of Starter
Inspection of Starter
(1) Armature coil short-circuit testPlace the armature on the growler. Set an iron piece parallel to the armature, and rotate the armature slowly by hand. If the iron piece is attracted to the coil or vibrates, there is a short-circuit; replace the armature.
Armature coil short-circuit test(2) Armature coil grounding testIf there is continuity between the commutator and shaft (or core), replace the armature.
Armature coil grounding test(3) Measurement of commutator runoutMeasure the commutator runout using a dial gage. If the amount of runout exceeds the limit value, replace the armature. If the commutator surface is rough, refinish the surface with sand paper (#300 to #500). If the surface has ridges due to abrasion, replace the armature since it is not repairable.
Measurement of commutator runout(4) Measurement of commutator outside diameterMeasure the outside diameter of the commutator, and, if the limit is exceeded, replace the armature.
Measurement of commutator outside diameter(5) Measurement of mold depth between segmentsClean the grooves between segments, and measure the mold depths between segments. If the limit value is exceeded, repair. (6) Inspection of armature gearIf the inspection of the armature gear finds abnormal wearing or chipped teeth, replace the armature.
Measurement of mold depth between segments(7) Yoke coil open-circuit testCheck to see if there is continuity between the terminal lead wire and brush (positive). If there is no continuity, there is an open-circuit; replace the yoke assembly.
Yoke coil open-circuit test(8) Yoke coil grounding testCheck to see if there is continuity between the yoke and brush (positive). If there is continuity, the yoke coil is grounded. Check the insulation, and replace the yoke assembly if the problem cannot be corrected.
Yoke coil grounding test(9) Inspection of magnetic switchConduct the following the following continuity tests, and, if there is any problem, replace the magnetic switch.(a) Coil open-circuit testCheck to see if there is continuity between terminal M and ground (case). There should be no continuity between terminal B and ground.(b) Inspection of contact adhesionCheck to make sure there is no continuity between terminal B and terminal M.
Inspection of magnetic switch(10) Measurement of brush lengthMeasure the length of each brush, and, if the limit value is exceeded, replace the brush. If the brush is unevenly worn or has a rough contact surface, refinish with sand paper (#300 to #500).
Measurement of brush length(11) Measurement of brush spring tensionMeasure the installation tension of each brush spring. Read the tension at the moment when the spring detaches from the brush. If the tension value is near the limit value, replace the brush spring.
Measurement of brush spring tension(12) Inspection of brush holders for insulationUsing a tester, check to make sure that there is no continuity between the positive-side brush holder and negative-side brush holder plate. If there is continuity, replace the brush holder.
Inspection of brush holder for insulation(13) Inspection of overrunning clutchMake sure that the pinion shaft rotates smoothly in one direction, and locks in place when it is turned in the opposite direction. If the pinion shaft does not

Have questions with 09210-00342?





Group cross 09210-00342

Back to top