09200-02650 PUMP ASSY, INJECTI Denso Cross


 

Information pump assy, injecti

Nozzle: 0935005480
09200-02650 PUMP ASSY, INJECTI
Rating:
50
Buy PUMP ASSY, INJECTI 09200-02650 genuine, new aftermarket engine parts with delivery

KIT List:

Pump assy, fuel fe 1922900060
Body assy, injecti 1904400300
Governor assy, mec 1908900170

Components :

001. PUMP ASSY, INJECTI 09200-02650
002. PUMP ASSY, FUEL FE 09210-01291
003. BODY ASSY, INJECTI 19010-00480
004. GOVERNOR ASSY, MEC 19080-05410

Scheme ###:

000. [01] 09200-02650 PUMP ASSY, INJECTI 32C6502070
005. [01] 19010-00480 BODY ASSY, INJECTI
006. [01] 19080-05410 GOVERNOR ASSY, MEC
007. [01] 09001-80081 COVER, CONTROL RAC 09001-80081
008. [01] 94905-02450 NUT, HEXAGON 94905-02450
009. [01] 94913-00190 KEY, WOODRUFF 94913-00190
010. [01] 94901-50500 WASHER, SPRING 94901-50500
012. [01] 09210-01291 PUMP ASSY, FUEL FE 34461-09060
013. [01] 91518-08221 BOLT, W/WASHER 91518-08221
014. [06] 91418-06161 BOLT, W/WASHER 91418-06161

Include in #3:

09200-02650 as PUMP ASSY, INJECTI

Cross reference number



Part num Firm num Firm Name
09200-02650  32C6502070  PUMP ASSY, INJECTI
32C6502070    MITSUBISHI PUMP ASSY, INJECTI




Information:

Inspection of Water Pump
If the inspection of the impeller and shaft finds abnormal noise or rough rotation, replace the assembly.
Inspection of impeller and shaft rotation conditionThermostat
Disassembly of Thermostat
Inspection of Thermostat
To test the thermostat operation, immerse the thermostat in a container filled with water, and heat the water while measuring the water temperature. Record the temperature at which the valve starts to open and the temperature at which the valve lift becomes 8 mm [0.3 in.] or more. (a) Stir the water in the container to ensure uniform temperature distribution.(b) When installing the thermostat, be sure to check the valve opening temperature indication stamped on the upper face of the thermostat mounting flange.
Inspection of thermostatOverheat Warning Unit (Thermo Switch)
Inspection of Overheat Warning Unit
Immerse the temperature sensor in oil, and measure the resistance while increasing the oil temperature. If the temperature measurement exceeds the standard value significantly, replace the thermo switch.
Since the inspection requires heating of oil to high temperatures, be careful not to get burns or start a fire.
Overheat warning unit