09200-00290 PUMP ASSY, INJECTI Denso Cross


 

Information pump assy, injecti

Nozzle: 0935005570
09200-00290 PUMP ASSY, INJECTI
Rating:
67
Buy PUMP ASSY, INJECTI 09200-00290 genuine, new aftermarket engine parts with delivery

KIT List:

Governor assy, mec 1908900720
Timer assy, automa No Application
Pump assy, fuel fe 1922900070
Body assy, injecti 1904400380

Components :

001. PUMP ASSY, INJECTI 09200-00290
002. GOVERNOR ASSY, MEC 09130-04420
003. LEVER SET 09129-10140
004. COMPENSATOR SUB-AS 19260-00591
005. TIMER ASSY, AUTOMA 09180-03430
006. PUMP ASSY, FUEL FE 09210-02730
007. COUPLING ASSY 09250-00870
008. BODY ASSY, INJECTI 19010-00110
009. COVER, BEARING 09020-10430

Scheme ###:

000. [01] 09200-00290 PUMP ASSY, INJECTI 22010-7200
000. [01] 09200-00290 PUMP ASSY, INJECTI S2201-07200
003. [01] 19010-00111 BODY ASSY, INJECTI 22110-2970A
004. [01] 09130-04420 GOVERNOR ASSY, MEC
005. [02] 94904-76880 BOLT, W/WASHER
006. [01] 09001-80420 COVER, CONTROL RAC 22114-1240A
007. [01] 09180-03430 TIMER ASSY, AUTOMA
008. [01] 09001-20340 NUT, TIMER ROUND
009. [04] 94904-76890 BOLT, W/WASHER 22815-3210A
010. [02] 91418-06121 BOLT, W/WASHER 22815-1500A
011. [01] 90458-05750 KEY, WOODRUFF 22891-1070A
012. [01] 09210-02730 PUMP ASSY, FUEL FE
013. [01] 09069-11500 BRACKET, STOP WIRE
014. [01] 94901-81550 WASHER, COPPER PLA 96542-2150A
015. [01] 09250-00870 COUPLING ASSY
016. [01] 94904-76910 BOLT, W/WASHER
017. [01] 94904-76900 BOLT, W/WASHER
019. [01] 09028-50030 CAP 22323-1210A
026. [01] 09069-00360 BRACKET SUB-ASSY,
027. [02] 91808-08121 BOLT, FLANGE
028. [01] 09031-00350 VALVE ASSY, OVERFL 22107-1470A
029. [03] 94901-02490 WASHER 22877-1100A
030. [01] 09028-50050 CAP 22323-1320A

Include in #3:

09200-00290 as PUMP ASSY, INJECTI
09200-00290

Cross reference number



Part num Firm num Firm Name
09200-00290  22010-7200  PUMP ASSY, INJECTI
22010-7200    HINO PUMP ASSY, INJECTI
S2201-07200    HINO PUMP ASSY, INJECTI




Information:

Introduction
Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.This form is to be used and filled out in any case that a DEF pump or DEF back flow valve is being replaced.The DEF pump troubleshooting return form needs to be completed and included with failed part returns documenting what was found that led to DEF pump or back flow valve replacement. Attach the photos of DEF pump and mount area and any photos requested as per the tables along with a Product Status Report to the Service Information Management System (SIMS) claim.Safety Section
Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs. A person must be alert to potential hazards, including human factors that can affect safety. This person should also have the necessary training, skills, and tools to perform these functions properly.
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.
Failure to follow all safety guidelines prescribed in this document and by governing authorities and regulatory agencies may result in severe injury or death of personnel or machine damage.
When removing a major component or attachment, ensure that it is properly blocked or secured before removing mounting hardware. An assembly that is disconnected without proper blocking may shift or fall, resulting in serious injury or death of personnel or machine damage.
Personal injury or death can result from improper maintenance procedures. To avoid injury or death, follow the procedures exactly as stated below.
Personal injury can result from improper handling of chemicals.Make sure you use all the necessary protective equipment required to do the job.Make sure that you read and understand all directions and hazards described on the labels and material safety data sheet of any chemical that is used.Observe all safety precautions recommended by the chemical manufacturer for handling, storage, and disposal of chemicals.
Climbing equipment may be required to access this service point. Refer to the Operation and Maintenance Manual, "Mounting and Dismounting" topic for safety information.
Before servicing/performing maintenance on the machine, electrical power must be physically disconnected; battery plugs must be disconnected from the batteries, or the trailing cable must be unplugged, and warning tags and padlocks shall be applied by a certified electrician. Certified electricians shall perform or direct any electrical work, including any energized testing, repair work in controllers, motors, or other approved compartments, and shall insure that all compartments are properly closed and inspected prior to re-energization. All applicable lock out and tag out procedures must be followed.
Observe the safe working load limits of all lifting and blocking devices and keep a safe distance from suspended/blocked loads. Personnel may

Have questions with 09200-00290?





Group cross 09200-00290

Back to top