09000-08461 PUMP ASSY, INJECTI Denso Cross


 

Information pump assy, injecti

09000-08461 PUMP ASSY, INJECTI
Rating:
65
Buy PUMP ASSY, INJECTI 09000-08461 genuine, new aftermarket engine parts with delivery

Components :

001. PUMP ASSY, INJECTI 09000-08461
002. BODY ASSY, INJECTI 09010-02480
003. COVER, BEARING 09020-10053
004. GOVERNOR ASSY, MEC 09080-03560
005. TIMER ASSY, AUTOMA 09180-00650
006. PUMP ASSY, FUEL FE 09210-00780
007. COUPLING ASSY 09240-00043

Scheme ###:

000. [01] 09000-08461 PUMP ASSY, INJECTI 22010-2550
007. [01] 09010-02480 BODY ASSY, INJECTI 6 305 1200 80
008. [01] 09080-03560 GOVERNOR ASSY, MEC 22310-1710
009. [06] 94904-71150 BOLT, W/WASHER 6 306 1001 00
011. [01] 94904-73910 BOLT, W/WASHER 22815-2820A
013. [01] 09001-80081 COVER, CONTROL RAC 22114-1130A
014. [01] 09180-00650 TIMER ASSY, AUTOMA 22510-1350
015. [01] 09001-20010 NUT, TIMER ROUND 22353-1050A
016. [01] 94913-00050 KEY, WOODRUFF 22891-1040A
017. [01] 90258-12001 WASHER, SPRING 22873-1310A
018. [01] 09210-00780 PUMP ASSY, FUEL FE 22570-1170
019. [01] 09006-10011 COVER, PRIMING PUM 6 053 1552 60
022. [01] 09240-00043 COUPLING ASSY 22610-1090A
023. [01] 09243-60040 COUPLING, INJECTIO 22612-1100A

Include in #3:

09000-08461 as PUMP ASSY, INJECTI

Cross reference number



Part num Firm num Firm Name
09000-08461  22010-2550  PUMP ASSY, INJECTI




Information:

If the engine has been operating at high load, run at low idle for at least three minutes before stopping. This cool down will reduce and stabilize internal engine coolant and oil temperatures before stopping the engine.If the engine has been operating at low loads, run the engine at low idle for 30 seconds before stopping.Make sure the shutoff procedure is understood. Refer to the Stopping the Engine instructions in the Generator Set Control Panel topic in this publication. Use the following general guidelines for stopping the engine.1. Open the Main electrical circuit breaker/Remove load from engine.2. Move the governor control to no more than half engine speed. Run the engine for three to five minutes.3. Reduce the engine speed to low idle.4. The engine may be stopped by using the Woodward Governor (if equipped), the Mechanical Governor (if equipped), or the solenoid shutoff switch.Woodward Actuator (If Equipped)
If equipped with a Woodward Actuator, move the control lever upward or forward, depending on the installation. Hold the lever to the OFF or STOP position until the engine stops.Mechanical Governor Control
A manual shutoff lever is provided to shut off the fuel from the fuel injection pump and override the governor control. The manual shutoff lever is located on the side of the pump.The engine can be shut OFF by rotating and holding the manual shutoff lever in the clockwise (CW) direction. If equipped with a Mechanical Governor Control, to move control to the SHUT OFF position: pull upward on the vernier hand grip while pushing down on thumb button. This shutdown will only move the fuel control linkage (rack) to the FUEL-OFF position. This does not shut off the air inlet.Solenoid Shutoff
Move the Control Panel Engine Control Switch (ECS, if equipped) to the STOP position.After Stopping the Engine
1. Fill the fuel tank to prevent accumulation of moisture in the fuel.2. Check the coolant level. Maintain the cooling system to 13 mm (1/2 inch) from bottom of the fill pipe. If freezing temperatures are expected, allow the radiator and engine jacket water system to cool, then check the coolant for proper antifreeze protection. The cooling system must be protected against freezing to the lowest expected ambient (outside) temperature. Add the proper coolant and water mixture if necessary.3. Check the crankcase oil level. Maintain the oil level between the ADD and FULL marks in the FULL RANGE zone on the dipstick.4. Repair any leaks, perform minor adjustments, tighten loose bolts, etc. 5. Note the service hour meter reading. Perform periodic maintenance as instructed in the Maintenance Schedule.

Have questions with 09000-08461?





Group cross 09000-08461

Back to top